Precision error of fan-beam dual X-ray absorptiometry scans at spine, hip, and forearm

被引:49
|
作者
Henzell, S
Dhaliwal, S
Pontifex, R
Gill, F
Price, R
Retallack, R
Prince, R
机构
[1] Sir Charles Gairdner Hosp, Dept Endocrinol & Diabet, Perth, WA, Australia
[2] Sir Charles Gairdner Hosp, Dept Med Technol & Phys, Perth, WA, Australia
[3] Univ Western Australia, Dept Med, Perth, WA 6009, Australia
关键词
dual X-ray absorptiometry; precision; Hologic; fan beam; compare;
D O I
10.1385/JCD:3:4:359
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The current study investigated short-term precision of fan-beam dual X-ray absorptiometry scans using a sample of subjects typically seen in a routine practice. Seventy-two women were scanned twice each in array fan-beam mode at the lumbar spine and 71 at the hip on a Hologic QDR 2000. Sixty-five were scanned at the forearm on a Hologic QDR 4500A in array mode. Each of the two scans was analyzed without reference to its companion scan (independent analysis). The second assessment was also reanalyzed using the manufacturer's "Compare" function (compared analysis). Coefficients of variation (CVs) were calculated for the two forms of analysis at all the sites measured. Paired t-tests were performed to see whether the Compare function improved precision. The CV at the lumbar spine was 1.1% in both forms of analysis. The Compare function did not improve precision significantly at this site. The highest precision at the hip was found at the "Total'' site of the hip (1.2-1.0%, independent and compared analyses, respectively) and the lowest at Ward's triangle (3.2-2.8%). The Compare function significantly improved precision at Ward's triangle. The forearm had the best precision of all the sites measured, with the Total site of the forearm highest (0.5-0.7%) and the ultra-distal sire lowest (1.6-1.8%). The Compare function significantly decreased precision at the middistal and Total sites of the forearm. In conclusion. the highest precision was found at the Total site of the hip, the Total site of the forearm, and the spine. The Compare function did not significantly improve precision at the spine or hip (with the exception of Ward's triangle) and decreased precision at the forearm.
引用
收藏
页码:359 / 364
页数:6
相关论文
共 50 条
  • [1] A Wide Fan-beam Dual-energy X-ray Absorptiometry for Forearm
    Li, Chan
    Li, Liang
    Chen, Zhiqiang
    [J]. 2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [2] DUAL X-RAY ABSORPTIOMETRY - A COMPARISON BETWEEN FAN-BEAM AND PENCIL BEAM SCANS
    BLAKE, GM
    PARKER, JC
    BUXTON, FMA
    FOGELMAN, I
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1993, 66 (790): : 902 - 906
  • [3] Dual X-ray Absorptiometry: Cross-Calibration of a New Fan-Beam System
    G. M. Blake
    E. J. Harrison
    J. E. Adams
    [J]. Calcified Tissue International, 2004, 75 : 7 - 14
  • [4] Dual X-ray absorptiometry: Cross-calibration of a new fan-beam system
    Blake, GM
    Harrison, EJ
    Adams, JE
    [J]. CALCIFIED TISSUE INTERNATIONAL, 2004, 75 (01) : 7 - 14
  • [5] Occupational dose to the radiographer in dual X-ray absorptiometry: A comparison of pencil-beam and fan-beam systems
    Patel, R
    Blake, GM
    Batchelor, S
    Fogelman, I
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1996, 69 (822): : 539 - 543
  • [6] Interchangeability of pencil-beam and fan-beam dual-energy X-ray absorptiometry measurements in piglets and infants
    Koo, WWK
    Hammami, M
    Hockman, EM
    [J]. AMERICAN JOURNAL OF CLINICAL NUTRITION, 2003, 78 (02): : 236 - 240
  • [7] Evaluation of peripheral dual energy X-ray absorptiometry: comparison with single photon absorptiometry of the forearm and dual energy X-ray absorptiometry of the spine or femur
    Mole, PA
    McMurdo, MET
    Paterson, CR
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (844): : 427 - 432
  • [8] Lateral spine dual energy X-ray absorptiometry - Bone mineral measurement with fan-beam design: Effect of osteophytic calcifications on lateral and anteroposterior spine BMD
    Franck, H
    Munz, M
    Scherrer, M
    vonLilienfeldToal, H
    [J]. RHEUMATOLOGY INTERNATIONAL, 1995, 15 (04) : 151 - 154
  • [9] Longitudinal reproducibility for measurement of body composition and bone mineral by a fan-beam dual energy x-ray absorptiometry
    Wang, J
    Thornton, J
    Ioannidou, E
    Gallagher, D
    Horlick, M
    Heymsfield, S
    Pierson, R
    Allen, L
    [J]. OBESITY RESEARCH, 2004, 12 : A227 - A227
  • [10] Multichannel FPGA-based Data Acquisition System for Fan-beam Dual Energy X-ray Absorptiometry
    Minh-Duc Hoang
    Kang, Jihoon
    [J]. JOURNAL OF MAGNETICS, 2022, 27 (04) : 498 - 505