Dual X-ray absorptiometry: Cross-calibration of a new fan-beam system

被引:32
|
作者
Blake, GM
Harrison, EJ
Adams, JE
机构
[1] Guys Kings & St Thomas Sch Med, London SE1 9RT, England
[2] Univ Manchester, Dept Clin Radiol, Manchester M13 9PT, Lancs, England
关键词
dual X-ray absorptiometry; longitudinal studies; cross-calibration;
D O I
10.1007/s00223-004-0169-y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The high precision and stable calibration of dual X-ray absorptiometry (DXA) scanners have led to their widespread use in longitudinal studies for research and the follow-up of individual patients who are receiving treatment for osteoporosis. However, difficulties in maintaining the continuity of the bone mineral density (BMD) calibration scale can arise when an old DXA system is replaced by a newer model. We report the results of an in vivo cross-calibration study performed when a GE-Lunar Prodigy fan-beam system replaced a DPX-L pencil-beam scanner. Lumbar spine and hip DXA scans were performed in 133 patients (104 female, 29 male) attending long-term BMD monitoring. On average, lumbar spine BMD measurements on the two systems agreed closely, with Prodigy values 1% lower than those on the DPX-L. However, after allowing for this difference. the root mean square error (RMSE) of 0.037 g/cm(2) was larger than in previous cross-calibration studies reported in the literature, and was 3 times the value expected from the precision of the BMD measurements. Mean femoral neck BMD also agreed closely between the two systems, although for Prodigy, the spread of measurements was 10% smaller than that for the DPX-L. For the trochanter and Ward's triangle regions. mean BMD was 4% and 6% lower, respectively, on the Prodigy system, and the results were affected by a similar compression of the range of values. RMSE values were 0.037 g/cm(2), 0.044 g/cm(2), and 0.044 g/cm(2), respectively. for the femoral neck, trochanter, and Ward's triangle sites. When the high value of the RMSE was investigated, it was found that for lumbar spine BMD, patient body weight and the difference between the two systems in the percentage fat reported in the soft tissue reference region explained 40% of the variance. This enabled equations to be developed that significantly improved the agreement between scans performed on the two systems. Smaller improvements were obtained for the femur BMD measurements.
引用
收藏
页码:7 / 14
页数:8
相关论文
共 50 条
  • [1] Dual X-ray Absorptiometry: Cross-Calibration of a New Fan-Beam System
    G. M. Blake
    E. J. Harrison
    J. E. Adams
    [J]. Calcified Tissue International, 2004, 75 : 7 - 14
  • [2] Cross-calibration of a fan-beam X-ray densitometer with a pencil-beam system
    Bouyoucef, SE
    Cullum, ID
    Jell, P
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1996, 69 (822): : 522 - 531
  • [3] Fat Tissue Measurements by Dual-Energy X-Ray Absorptiometry: Cross-Calibration of 3 Different Fan-Beam Instruments
    Malouf, Jorge
    DiGregorio, Silvana
    Del Rio, Luis
    Torres, Ferran
    Marin, Ana M.
    Farrerons, Jordi
    Herrera, Silvia
    Domingo, Pere
    [J]. JOURNAL OF CLINICAL DENSITOMETRY, 2013, 16 (02) : 212 - 222
  • [4] REPLACING DUAL X-RAY ABSORPTIOMETRY SCANNERS - CROSS-CALIBRATION OF A NEW MULTIDETECTOR ARRAY SYSTEM
    BLAKE, GM
    FOGELMAN, I
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 1995, 10 : S267 - S267
  • [5] Cross-calibration of pencil-beam (DPX-NT) and fan-beam (QDR-4500C) dual-energy X-ray absorptiometry for sarcopenia
    Ito, Kenyu
    Tsushita, Kazuyo
    Muramoto, Akiko
    Kanzaki, Hiroki
    Nohara, Takashi
    Shimizu, Hitomi
    Nakazawa, Tomoko
    Harada, Atsushi
    [J]. NAGOYA JOURNAL OF MEDICAL SCIENCE, 2015, 77 (04): : 647 - 652
  • [6] DUAL X-RAY ABSORPTIOMETRY - A COMPARISON BETWEEN FAN-BEAM AND PENCIL BEAM SCANS
    BLAKE, GM
    PARKER, JC
    BUXTON, FMA
    FOGELMAN, I
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1993, 66 (790): : 902 - 906
  • [7] A Wide Fan-beam Dual-energy X-ray Absorptiometry for Forearm
    Li, Chan
    Li, Liang
    Chen, Zhiqiang
    [J]. 2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [8] Bone mineral and body composition measurements: Cross-calibration of pencil-beam and fan-beam dual-energy X-ray absorptiometers
    Ellis, KJ
    Shypailo, RJ
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 1998, 13 (10) : 1613 - 1618
  • [9] Phantoms for cross-calibration of dual energy X-ray absorptiometry measurements in infants
    Hammami, M
    Picaud, JC
    Fusch, C
    Rigo, J
    Koo, W
    [J]. PEDIATRIC RESEARCH, 2002, 51 (04) : 406A - 406A
  • [10] Phantoms for cross-calibration of dual energy X-ray absorptiometry measurements in infants
    Hammami, M
    Picaud, JC
    Fusch, C
    Hockman, EM
    Rigo, J
    Koo, WWK
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF NUTRITION, 2002, 21 (04) : 328 - 332