Fat Tissue Measurements by Dual-Energy X-Ray Absorptiometry: Cross-Calibration of 3 Different Fan-Beam Instruments

被引:20
|
作者
Malouf, Jorge [1 ]
DiGregorio, Silvana [2 ]
Del Rio, Luis [2 ]
Torres, Ferran [3 ]
Marin, Ana M. [1 ]
Farrerons, Jordi [1 ]
Herrera, Silvia [1 ]
Domingo, Pere [1 ]
机构
[1] Univ Autonoma Barcelona, Dept Internal Med, Mineral Metab Unit, Hosp Santa Creu & St Pau, E-08193 Barcelona, Spain
[2] CETIR Med Grp, Dept Densitometry, Barcelona, Spain
[3] Univ Barcelona, Hosp Clin, Inst Invest Biomed August Pi & Sunyer IDIBAPS, Barcelona, Spain
关键词
Bland-Altman analysis; body fat measurements; cross-calibration; dual-energy X-ray absorptiometry; fan-beam scanners; BODY-COMPOSITION; FRACTIONAL POLYNOMIALS; PENCIL BEAM; AGREEMENT; VARIABLES; QDR-1000; SYSTEMS; LUNAR;
D O I
10.1016/j.jocd.2012.04.003
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Analysis of total tissue composition and, particularly, body fat measurements has become progressively important in the diagnosis and follow-up of patients with different clinical conditions. Dual-energy X-ray absorptiometry (DXA) fan-beam scanners are widely used to measure body composition, but the development of translational equations to be able to compare data of different scanning systems is necessary. The aim of this study was to assess the extent of agreement for regional measurements of body composition among the following 3 fan-beam DXA scanners: (1) Hologic Discovery (Hologic, Inc., Waltham, MA), (2) Lunar iDXA (GE Healthcare, Madison, WI), and (3) Lunar Prodigy Advance (GE Healthcare, Madison, WI). The study population consisted of 91 adult healthy volunteers (40 males and 51 females; mean age 48.5 +/- 14.4 yr) who underwent DXA evaluation of the lumbar spine, hip, and whole body in each machine on the same day. Agreement among the 3 scanners was evaluated according to the Bland-Altman method and Lin's concordance correlation coefficient. Results showed a better agreement and concordance for the Lunar iDXA scanner than for any of them with the Hologic scanner. Differences were higher for any tissue or region than for the whole tissue mass. Translational equations were developed to ensure comparability of body composition measurements obtained with each of these 3 scanners.
引用
收藏
页码:212 / 222
页数:11
相关论文
共 50 条
  • [1] Dual X-ray Absorptiometry: Cross-Calibration of a New Fan-Beam System
    G. M. Blake
    E. J. Harrison
    J. E. Adams
    [J]. Calcified Tissue International, 2004, 75 : 7 - 14
  • [2] Dual X-ray absorptiometry: Cross-calibration of a new fan-beam system
    Blake, GM
    Harrison, EJ
    Adams, JE
    [J]. CALCIFIED TISSUE INTERNATIONAL, 2004, 75 (01) : 7 - 14
  • [3] Bone mineral and body composition measurements: Cross-calibration of pencil-beam and fan-beam dual-energy X-ray absorptiometers
    Ellis, KJ
    Shypailo, RJ
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 1998, 13 (10) : 1613 - 1618
  • [4] A Wide Fan-beam Dual-energy X-ray Absorptiometry for Forearm
    Li, Chan
    Li, Liang
    Chen, Zhiqiang
    [J]. 2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [5] Cross-calibration of pencil-beam (DPX-NT) and fan-beam (QDR-4500C) dual-energy X-ray absorptiometry for sarcopenia
    Ito, Kenyu
    Tsushita, Kazuyo
    Muramoto, Akiko
    Kanzaki, Hiroki
    Nohara, Takashi
    Shimizu, Hitomi
    Nakazawa, Tomoko
    Harada, Atsushi
    [J]. NAGOYA JOURNAL OF MEDICAL SCIENCE, 2015, 77 (04): : 647 - 652
  • [6] Interchangeability of pencil-beam and fan-beam dual-energy X-ray absorptiometry measurements in piglets and infants
    Koo, WWK
    Hammami, M
    Hockman, EM
    [J]. AMERICAN JOURNAL OF CLINICAL NUTRITION, 2003, 78 (02): : 236 - 240
  • [7] Phantoms for cross-calibration of dual energy X-ray absorptiometry measurements in infants
    Hammami, M
    Picaud, JC
    Fusch, C
    Rigo, J
    Koo, W
    [J]. PEDIATRIC RESEARCH, 2002, 51 (04) : 406A - 406A
  • [8] Phantoms for cross-calibration of dual energy X-ray absorptiometry measurements in infants
    Hammami, M
    Picaud, JC
    Fusch, C
    Hockman, EM
    Rigo, J
    Koo, WWK
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF NUTRITION, 2002, 21 (04) : 328 - 332
  • [9] Technical considerations for fan-beam dual-energy x-ray absorptiometry body composition measurements in pediatric studies
    Hammami, M
    Koo, WWK
    Hockman, EM
    [J]. JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 2004, 28 (05) : 328 - 333
  • [10] Cross-calibration of a fan-beam X-ray densitometer with a pencil-beam system
    Bouyoucef, SE
    Cullum, ID
    Jell, P
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1996, 69 (822): : 522 - 531