Technical considerations for fan-beam dual-energy x-ray absorptiometry body composition measurements in pediatric studies

被引:19
|
作者
Hammami, M
Koo, WWK
Hockman, EM
机构
[1] Wayne State Univ, Dept Pediat Obsted & Gynecol, Detroit, MI USA
[2] Wayne State Univ, Dept Comp & Informat Technol, Detroit, MI USA
关键词
D O I
10.1177/0148607104028005328
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Background: A piglet model was used to determine the influence of frequently encountered situations in clinical studies of infants and young children on fan-beam dual-energy x-ray absorptiometry (DXA) measurements. Methods: DXA scans of piglets (640 g to 21,100 g) were acquired in the infant and adult mode and were analyzed with 1 infant, 1 pediatric, and 3 versions of adult software. Results: The effect of repositioning of the piglets from the center to the periphery of the scanning table on DXA measurements included an average difference of up to 0.5% for total weight, 5.0% for bone mineral content, 5.6% for bone mineral density, 1.3% for lean mass, and 21.9% for fat mass (p less than or equal to .05, all comparisons) although no significant changes occurred when the piglets were scanned in symmetrical positions on either edge of the scanning table. Different posture (prone vs supine and side), varied number of blankets overlaid or wrapped around the piglet, and parenteral but not enteral bolus feeding could significantly alter fan-beam DXA measurements to varying extents. Adult and pediatric software underestimated bone area and bone mineral content but overestimated bone mineral density, lean mass, fat mass, and total weight compared with infant software measurements. However, strong predictive relationships among these fan-beam DXA data in subjects > 10 kg allow systematic corrections of data from different scan modes and different software. Conclusions: Attention to details and consistency in the technique for scan acquisition and analysis are critical to the generation of meaningful data and to allow for detection of true differences in DXA measurements of small subjects.
引用
收藏
页码:328 / 333
页数:6
相关论文
共 50 条
  • [1] A Wide Fan-beam Dual-energy X-ray Absorptiometry for Forearm
    Li, Chan
    Li, Liang
    Chen, Zhiqiang
    [J]. 2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [2] Body composition measurements with fan beam dual energy x-ray absorptiometry
    Koo, W
    Hammami, M
    [J]. PEDIATRIC RESEARCH, 2002, 51 (04) : 314A - 315A
  • [3] Interchangeability of body composition measurements between pencil- and fan-beam dual energy X-ray absorptiometry measurements
    Koo, W
    Hammami, M
    [J]. PEDIATRIC RESEARCH, 2002, 51 (04) : 189A - 189A
  • [4] Fan beam dual energy X-ray absorptiometry body composition measurements in piglets
    Chauhan, S
    Koo, WWK
    Hammami, M
    Hockman, EM
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF NUTRITION, 2003, 22 (05) : 408 - 414
  • [5] Interchangeability of pencil-beam and fan-beam dual-energy X-ray absorptiometry measurements in piglets and infants
    Koo, WWK
    Hammami, M
    Hockman, EM
    [J]. AMERICAN JOURNAL OF CLINICAL NUTRITION, 2003, 78 (02): : 236 - 240
  • [6] ACCURACY OF DUAL-ENERGY X-RAY ABSORPTIOMETRY (DXA) FOR BODY-COMPOSITION MEASUREMENTS IN PEDIATRIC STUDIES
    ELLIS, K
    SHYPAILO, R
    PRATT, J
    MERSMANN, H
    POND, W
    [J]. FASEB JOURNAL, 1993, 7 (03): : A359 - A359
  • [7] Pediatric body composition analysis with dual-energy X-ray absorptiometry
    Maura Helba
    Larry A. Binkovitz
    [J]. Pediatric Radiology, 2009, 39 : 647 - 656
  • [8] Pediatric body composition analysis with dual-energy X-ray absorptiometry
    Helba, Maura
    Binkovitz, Larry A.
    [J]. PEDIATRIC RADIOLOGY, 2009, 39 (07) : 647 - 656
  • [9] Bone and body composition measurements of small subjects: Discrepancies from software for fan-beam dual energy X-ray absorptiometry
    Koo, WWK
    Hammami, M
    Shypailo, RJ
    Ellis, KJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF NUTRITION, 2004, 23 (06) : 647 - 650
  • [10] Longitudinal reproducibility for measurement of body composition and bone mineral by a fan-beam dual energy x-ray absorptiometry
    Wang, J
    Thornton, J
    Ioannidou, E
    Gallagher, D
    Horlick, M
    Heymsfield, S
    Pierson, R
    Allen, L
    [J]. OBESITY RESEARCH, 2004, 12 : A227 - A227