Technical considerations for fan-beam dual-energy x-ray absorptiometry body composition measurements in pediatric studies

被引:19
|
作者
Hammami, M
Koo, WWK
Hockman, EM
机构
[1] Wayne State Univ, Dept Pediat Obsted & Gynecol, Detroit, MI USA
[2] Wayne State Univ, Dept Comp & Informat Technol, Detroit, MI USA
关键词
D O I
10.1177/0148607104028005328
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Background: A piglet model was used to determine the influence of frequently encountered situations in clinical studies of infants and young children on fan-beam dual-energy x-ray absorptiometry (DXA) measurements. Methods: DXA scans of piglets (640 g to 21,100 g) were acquired in the infant and adult mode and were analyzed with 1 infant, 1 pediatric, and 3 versions of adult software. Results: The effect of repositioning of the piglets from the center to the periphery of the scanning table on DXA measurements included an average difference of up to 0.5% for total weight, 5.0% for bone mineral content, 5.6% for bone mineral density, 1.3% for lean mass, and 21.9% for fat mass (p less than or equal to .05, all comparisons) although no significant changes occurred when the piglets were scanned in symmetrical positions on either edge of the scanning table. Different posture (prone vs supine and side), varied number of blankets overlaid or wrapped around the piglet, and parenteral but not enteral bolus feeding could significantly alter fan-beam DXA measurements to varying extents. Adult and pediatric software underestimated bone area and bone mineral content but overestimated bone mineral density, lean mass, fat mass, and total weight compared with infant software measurements. However, strong predictive relationships among these fan-beam DXA data in subjects > 10 kg allow systematic corrections of data from different scan modes and different software. Conclusions: Attention to details and consistency in the technique for scan acquisition and analysis are critical to the generation of meaningful data and to allow for detection of true differences in DXA measurements of small subjects.
引用
收藏
页码:328 / 333
页数:6
相关论文
共 50 条
  • [31] Technical standardization for dual-energy X-ray absorptiometry
    Leib, E
    [J]. JOURNAL OF CLINICAL DENSITOMETRY, 2004, 7 (01) : 27 - 36
  • [32] Accuracy and precision of dual-energy X-ray absorptiometry for body composition measurements in rhesus monkeys
    Black, A
    Tilmont, EM
    Baer, DJ
    Rumpler, DK
    Roth, GS
    Lane, MA
    [J]. JOURNAL OF MEDICAL PRIMATOLOGY, 2001, 30 (02) : 94 - 99
  • [33] Body composition assessment by dual-energy X-ray absorptiometry: Comparison of prone and supine measurements
    Lambrinoudaki, I
    Georgiou, E
    Douskas, G
    Tsekes, G
    Kyriakidis, M
    Proukakis, C
    [J]. METABOLISM-CLINICAL AND EXPERIMENTAL, 1998, 47 (11): : 1379 - 1382
  • [34] Body composition analysis by dual X-ray absorptiometry:: in vivo and in vitro comparison of three different fan-beam instruments
    Aasen, G.
    Fagertun, H.
    Halse, J.
    [J]. SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2006, 66 (08): : 659 - 666
  • [35] DUAL X-RAY ABSORPTIOMETRY - A COMPARISON BETWEEN FAN-BEAM AND PENCIL BEAM SCANS
    BLAKE, GM
    PARKER, JC
    BUXTON, FMA
    FOGELMAN, I
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1993, 66 (790): : 902 - 906
  • [36] Precision of body composition measurements by dual energy X-ray absorptiometry
    Braillon, P
    Lapillonne, A
    Giraud, S
    Salle, BL
    Cochat, P
    [J]. APPLIED RADIATION AND ISOTOPES, 1998, 49 (5-6) : 501 - 502
  • [37] Dual-energy X-ray absorptiometry for the measurement of gross body composition in rats
    Jebb, SA
    Garland, SW
    Jennings, G
    Elia, M
    [J]. BRITISH JOURNAL OF NUTRITION, 1996, 75 (06) : 803 - 809
  • [38] Dual-energy X-ray absorptiometry for body composition estimation in Chinese women
    M He
    ETS Li
    AWC Kung
    [J]. European Journal of Clinical Nutrition, 1999, 53 : 933 - 937
  • [39] Precision of dual-energy X-ray absorptiometry for determining body composition of rats
    Carroll, WF
    Nagy, TR
    [J]. OBESITY RESEARCH, 2001, 9 : 108S - 108S
  • [40] Dual-energy X-ray absorptiometry for body composition estimation in Chinese women
    He, M
    Li, ETS
    Kung, AWC
    [J]. EUROPEAN JOURNAL OF CLINICAL NUTRITION, 1999, 53 (12) : 933 - 937