Artificial Intelligence Application to Screen Abdominal Aortic Aneurysm Using Computed tomography Angiography

被引:0
|
作者
Giovanni Spinella
Alice Fantazzini
Alice Finotello
Elena Vincenzi
Gian Antonio Boschetti
Francesca Brutti
Marco Magliocco
Bianca Pane
Curzio Basso
Michele Conti
机构
[1] University of Genoa,Department of Surgical Sciences and Integrated Diagnostics (DISC)
[2] IRCCS Ospedale Policlinico San Martino,Vascular and Endovascular Surgery Clinic
[3] Camelot Biomedical System,Department of Computer Science, Robotics and Systems Engineering
[4] IRCCS MultiMedica,Vascular Surgery Unit
[5] University of Genoa,Department of Mathematics
[6] AULSS 2 Marca Trevigiana,Department of Civil Engineering and Architecture
[7] Treviso Hospital,undefined
[8] University of Trento,undefined
[9] University of Pavia,undefined
关键词
Artificial intelligence (AI); Deep learning (DL); Abdominal aortic aneurysm (AAA); Screening;
D O I
暂无
中图分类号
学科分类号
摘要
The aim of our study is to validate a totally automated deep learning (DL)-based segmentation pipeline to screen abdominal aortic aneurysms (AAA) in computed tomography angiography (CTA) scans. We retrospectively evaluated 73 thoraco-abdominal CTAs (48 AAA and 25 control CTA) by means of a DL-based segmentation pipeline built on a 2.5D convolutional neural network (CNN) architecture to segment lumen and thrombus of the aorta. The maximum aortic diameter of the abdominal tract was compared using a threshold value (30 mm). Blinded manual measurements from a radiologist were done in order to create a true comparison. The screening pipeline was tested on 48 patients with aneurysm and 25 without aneurysm. The average diameter manually measured was 51.1 ± 14.4 mm for patients with aneurysms and 21.7 ± 3.6 mm for patients without aneurysms. The pipeline correctly classified 47 AAA out of 48 and 24 control patients out of 25 with 97% accuracy, 98% sensitivity, and 96% specificity. The automated pipeline of aneurysm measurements in the abdominal tract reported a median error with regard to the maximum abdominal diameter measurement of 1.3 mm. Our approach allowed for the maximum diameter of 51.2 ± 14.3 mm in patients with aneurysm and 22.0 ± 4.0 mm in patients without an aneurysm. The DL-based screening for AAA is a feasible and accurate method, calling for further validation using a larger pool of diagnostic images towards its clinical use.
引用
收藏
页码:2125 / 2137
页数:12
相关论文
共 50 条
  • [41] Screening Chest Computed Tomography is Indicated in All Patients with Abdominal Aortic Aneurysm
    Dombrowski, Danielle
    Long, Graham W.
    Chan, Jonathan
    Brown, O. William
    [J]. ANNALS OF VASCULAR SURGERY, 2020, 65 : 190 - 195
  • [42] ASSOCIATED LYMPHOMA AND ABDOMINAL AORTIC-ANEURYSM DEMONSTRATED BY COMPUTED-TOMOGRAPHY
    KREEL, L
    BYDDER, G
    [J]. CT-JOURNAL OF COMPUTED TOMOGRAPHY, 1980, 4 (03): : 209 - 214
  • [43] Computed Tomography Postprocessing for Abdominal Aortic Aneurysm Lumen Recognition in Unenhanced Examinations
    Cieri, Enrico
    Simonte, Gioele
    Costarelli, Danilo
    Fiorucci, Beatrice
    Isernia, Giacomo
    Seracini, Marco
    Vinti, Gianluca
    [J]. ANNALS OF VASCULAR SURGERY, 2019, 60 : 407 - 414
  • [44] Computed tomography assessment of abdominal aortic aneurysm morphology after endograft exclusion
    White, RA
    Donayre, CE
    Walot, I
    Woody, J
    Kim, N
    Kopchok, GE
    [J]. JOURNAL OF VASCULAR SURGERY, 2001, 33 (02) : S1 - S10
  • [45] COMPUTED-TOMOGRAPHY IN THE EVALUATION OF THE PATIENT WITH SYMPTOMATIC ABDOMINAL AORTIC-ANEURYSM
    ZARNKE, MD
    GOULD, HR
    GOLDMAN, MH
    [J]. SURGERY, 1988, 103 (06) : 638 - 642
  • [46] Diagnostic Accuracy of Computed Tomography in Patients with Suspected Abdominal Aortic Aneurysm Rupture
    Biancari, F.
    Paone, R.
    Venermo, M.
    D'Andrea, V.
    Perala, J.
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2013, 45 (03) : 227 - 230
  • [47] Comparison with computed tomography of two ultrasound devices for diagnosis of abdominal aortic aneurysm
    Vidakovic, Radosav
    Feringa, Harm H. H.
    Kuiper, Ruud J.
    Karagiannis, Stefanos E.
    Schouten, Olaf
    Dunkelgrun, Martin
    Hoeks, Sanne E.
    Bom, Nicolaas
    Bax, Jeroen J.
    Neskovic, Aleksandar N.
    Poldermans, Don
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2007, 100 (12): : 1786 - 1791
  • [48] Quantification of aortic distensibility in abdominal aortic aneurysm using ECG-gated multi-detector computed tomography
    Ganten, Maria-Katharina
    Krautter, Ute
    von Tengg-Kobligk, Hendrik
    Boeckler, Dittmar
    Schumacher, Hardy
    Stiller, Wolfram
    Delorme, Stefan
    Kauezor, Hans-Ulrich
    Kauffmann, Guenter W.
    Bock, Michael
    [J]. EUROPEAN RADIOLOGY, 2008, 18 (05) : 966 - 973
  • [49] Quantification of aortic distensibility in abdominal aortic aneurysm using ECG-gated multi-detector computed tomography
    Maria-Katharina Ganten
    Ute Krautter
    Hendrik von Tengg-Kobligk
    Dittmar Böckler
    Hardy Schumacher
    Wolfram Stiller
    Stefan Delorme
    Hans-Ulrich Kauczor
    Günter W. Kauffmann
    Michael Bock
    [J]. European Radiology, 2008, 18 : 966 - 973
  • [50] Artificial intelligence and automatic segmentation of abdominal aortic aneurysm: Past, present, and future
    Lareyre, Fabien
    Adam, Cedric
    Carrier, Marion
    Raffort, Juliette
    [J]. JOURNAL OF VASCULAR SURGERY, 2021, 74 (01) : 347 - 348