Artificial Intelligence Application to Screen Abdominal Aortic Aneurysm Using Computed tomography Angiography

被引:0
|
作者
Giovanni Spinella
Alice Fantazzini
Alice Finotello
Elena Vincenzi
Gian Antonio Boschetti
Francesca Brutti
Marco Magliocco
Bianca Pane
Curzio Basso
Michele Conti
机构
[1] University of Genoa,Department of Surgical Sciences and Integrated Diagnostics (DISC)
[2] IRCCS Ospedale Policlinico San Martino,Vascular and Endovascular Surgery Clinic
[3] Camelot Biomedical System,Department of Computer Science, Robotics and Systems Engineering
[4] IRCCS MultiMedica,Vascular Surgery Unit
[5] University of Genoa,Department of Mathematics
[6] AULSS 2 Marca Trevigiana,Department of Civil Engineering and Architecture
[7] Treviso Hospital,undefined
[8] University of Trento,undefined
[9] University of Pavia,undefined
关键词
Artificial intelligence (AI); Deep learning (DL); Abdominal aortic aneurysm (AAA); Screening;
D O I
暂无
中图分类号
学科分类号
摘要
The aim of our study is to validate a totally automated deep learning (DL)-based segmentation pipeline to screen abdominal aortic aneurysms (AAA) in computed tomography angiography (CTA) scans. We retrospectively evaluated 73 thoraco-abdominal CTAs (48 AAA and 25 control CTA) by means of a DL-based segmentation pipeline built on a 2.5D convolutional neural network (CNN) architecture to segment lumen and thrombus of the aorta. The maximum aortic diameter of the abdominal tract was compared using a threshold value (30 mm). Blinded manual measurements from a radiologist were done in order to create a true comparison. The screening pipeline was tested on 48 patients with aneurysm and 25 without aneurysm. The average diameter manually measured was 51.1 ± 14.4 mm for patients with aneurysms and 21.7 ± 3.6 mm for patients without aneurysms. The pipeline correctly classified 47 AAA out of 48 and 24 control patients out of 25 with 97% accuracy, 98% sensitivity, and 96% specificity. The automated pipeline of aneurysm measurements in the abdominal tract reported a median error with regard to the maximum abdominal diameter measurement of 1.3 mm. Our approach allowed for the maximum diameter of 51.2 ± 14.3 mm in patients with aneurysm and 22.0 ± 4.0 mm in patients without an aneurysm. The DL-based screening for AAA is a feasible and accurate method, calling for further validation using a larger pool of diagnostic images towards its clinical use.
引用
收藏
页码:2125 / 2137
页数:12
相关论文
共 50 条
  • [21] Application of Artificial Intelligence to Cardiovascular Computed Tomography
    Yang, Dong Hyun
    [J]. KOREAN JOURNAL OF RADIOLOGY, 2021, 22 (10) : 1597 - 1608
  • [22] Study on the clinical value of computed tomography angiography in the diagnosis of aortic aneurysm
    Yan, Ji-Lai
    [J]. JOURNAL OF CARDIOTHORACIC SURGERY, 2024, 19 (01)
  • [23] Through-Plane Movement at Multiple Aortic Levels on Dynamic Computed Tomography Angiography Is Limited in Patients With an Abdominal Aortic Aneurysm
    de Jonge, Jeroen C.
    Zandvoort, Herman J. A.
    Vonken, Evert-Jan P. A.
    Moll, Frans L.
    van Herwaarden, Joost A.
    [J]. JOURNAL OF ENDOVASCULAR THERAPY, 2015, 22 (05) : 765 - 769
  • [24] Abdominal aortic aneurysm morphology in candidates for endovascular repair evaluated with spiral computed tomography and digital subtraction angiography
    Resch, T
    Ivancev, K
    Lindh, M
    Nirhov, N
    Nyman, U
    Lindblad, B
    [J]. JOURNAL OF ENDOVASCULAR SURGERY, 1999, 6 (03): : 227 - 232
  • [25] INTRAVENOUS DIGITAL SUBTRACTION ANGIOGRAPHY VERSUS COMPUTED-TOMOGRAPHY IN THE ASSESSMENT OF ABDOMINAL AORTIC-ANEURYSM - REPLY
    SALAMAN, RA
    FLIGELSTONE, L
    LANE, IF
    [J]. BRITISH JOURNAL OF SURGERY, 1994, 81 (10) : 1544 - 1544
  • [26] Measuring abdominal aortic diameters in routine abdominal computed tomography scans and implications for abdominal aortic aneurysm screening
    Claridge, Rachel
    Arnold, Sam
    Morrison, Neil
    van Rij, Andre M.
    [J]. JOURNAL OF VASCULAR SURGERY, 2017, 65 (06) : 1637 - 1642
  • [27] Differences between endovascular abdominal aortic aneurysm repair planning using three-dimensional reconstruction versus computed tomography and angiography
    Morales Gisbert, S. M.
    Zaragoza Garcia, J. M.
    Gomez Palones, F. J.
    Bargay Juan, P.
    Ramirez Montoya, M.
    Ortiz Monzon, E.
    [J]. ANGIOLOGIA, 2014, 66 (04): : 183 - 189
  • [28] Computed Tomography Angiography in Abdominal Aortic Endoleaks: What Is the Optimal Protocol?
    Kirby, John M.
    Jhaveri, Kartik S.
    Kachura, John R.
    [J]. CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2007, 58 (05): : 264 - 271
  • [29] Computed tomography imaging of macrophage phagocytic activity in abdominal aortic aneurysm
    Toczek, Jakub
    Boodagh, Parnaz
    Sanzida, Nowshin
    Ghim, Mean
    Salarian, Mani
    Gona, Kiran
    Kukreja, Gunjan
    Rajendran, Saranya
    Wei, Linyan
    Han, Jinah
    Zhang, Jiasheng
    Jung, Jae-Joon
    Graham, Morven
    Liu, Xinran
    Sadeghi, Mehran M.
    [J]. THERANOSTICS, 2021, 11 (12): : 5876 - 5888
  • [30] The value of computed tomography in the assessment of suspected ruptured abdominal aortic aneurysm
    Adam, DJ
    Bradbury, AW
    Stuart, WP
    Woodburn, KR
    Murie, JA
    Jenkins, AML
    Ruckley, CV
    [J]. JOURNAL OF VASCULAR SURGERY, 1998, 27 (03) : 431 - 437