A field study on the application of distributed temperature sensing technology in thermal response tests for borehole heat exchangers

被引:0
|
作者
Dingfeng Cao
Bin Shi
Hong-Hu Zhu
Guangqing Wei
Hainar Bektursen
Mengya Sun
机构
[1] Nanjing University,School of Earth Sciences and Engineering
[2] University of Wisconsin–Madison,Department of Civil and Environmental Engineering, Engineering College
[3] Suzhou NanZee Sensing Technology Co.,undefined
[4] Ltd.,undefined
关键词
Distributed temperature sensing (DTS); Thermal response test (TRT); Ground-coupled heat pump (GCHP); Thermal conductivity; Fiber optic sensor;
D O I
暂无
中图分类号
学科分类号
摘要
Although the enhanced thermal response test (ETRT) method has been used to determine the distribution of ground temperatures and effective thermal conductivities, there are a number of obstacles which limit the wide application of this technology in the discipline of geoengineering. In this literature, four aspects of ETRT technology were investigated: (a) acquisition of ground temperature, (b) installation of the heat exchange tubes, (c) optimization of the monitoring positions, and (d) the difference in thermal conductivity obtained by the ETRT and numerical simulation. To investigate these issues, a field trial was carried out in Heze, Shandong Province, China, and the corresponding numerical models were built. The results demonstrate that: (i) the conventional methods that infer undisturbed ground temperature using water in tubes have large errors, whereas the distributed temperature sensing (DTS) technique enables the measurement of precise temperature profiles; (ii) the thermal conductivity measured using double U-tubes reflects the soil thermal property more accurately than that for a single U-tube; (iii) it is more reasonable to install optical fibers outside the U-tube sidewall than inside the observation tube; and (iv) it is essential to quantitatively consider various interface thermal impedance when estimating ground thermal conductivities using numerical simulation.
引用
收藏
页码:3901 / 3915
页数:14
相关论文
共 50 条
  • [21] Comparison of ground temperature response of energy pile and borehole heat exchanger during thermal response tests
    Luo, Jin
    Zhao, Haifeng
    Gui, Shuqiqang
    Xiang, Wei
    Rohn, Joachim
    [J]. ENVIRONMENTAL EARTH SCIENCES, 2016, 75 (22)
  • [22] Comparison of ground temperature response of energy pile and borehole heat exchanger during thermal response tests
    Jin Luo
    Haifeng Zhao
    Shuqiqang Gui
    Wei Xiang
    Joachim Rohn
    [J]. Environmental Earth Sciences, 2016, 75
  • [23] The simplified calculation method of the thermal response radius for vertical borehole heat exchangers
    [J]. Zhang, Zhengwei (zwzhang10@126.com), 1600, Science Press (37):
  • [24] On the Influence of Operational and Control Parameters in Thermal Response Testing of Borehole Heat Exchangers
    Badenes, Borja
    Mateo Pla, Miguel Angel
    Lemus-Zuniga, Lenin G.
    Saiz Mauleon, Begon
    Urchueguia, Javier F.
    [J]. ENERGIES, 2017, 10 (09):
  • [25] TEMPERATURE FIELD SIMULATION OF BOREHOLE GROUND HEAT EXCHANGERS CONSIDERING HYDROGEOLOGIC CONDITIONS
    Yu, Y. J.
    Long, H.
    Feng, Z. Q.
    [J]. PROCEEDINGS OF THE FIRST INTERNATIONAL CONFERENCE ON SUSTAINABLE URBANIZATION (ICSU 2010), 2010, : 756 - 763
  • [26] Computational methods for ground thermal response of multiple borehole heat exchangers: A review
    Zhang, Changxing
    Wang, Yusheng
    Liu, Yufeng
    Kong, Xiangqiang
    Wang, Qing
    [J]. RENEWABLE ENERGY, 2018, 127 : 461 - 473
  • [27] Numerical modeling of ground thermal response with borehole heat exchangers connected in parallel
    Monzo, Patricia
    Puttige, Anjan Rao
    Acuna, Jose
    Mogensen, Palne
    Cazorla, Antonio
    Rodriguez, Juan
    Montagud, Carla
    Cerdeira, Fernando
    [J]. ENERGY AND BUILDINGS, 2018, 172 : 371 - 384
  • [28] Interpretation of ongoing thermal response tests of vertical (BHE) borehole heat exchangers with predictive uncertainty based stopping criterion
    Poulsen, S. E.
    Alberdi-Pagola, M.
    [J]. ENERGY, 2015, 88 : 157 - 167
  • [29] Improved method and case study of thermal response test for borehole heat exchangers of ground source heat pump system
    Wang, Huajun
    Qi, Chengying
    Du, Hongpu
    Gu, Jihao
    [J]. RENEWABLE ENERGY, 2010, 35 (03) : 727 - 733
  • [30] Investigation of the influence of soil moisture on thermal response tests using active distributed temperature sensing (A-DTS) technology
    Cao, Dingfeng
    Shi, Bin
    Loheide, Steven P., II
    Gong, Xulong
    Zhu, Hong-Hu
    Wei, Guangqing
    Yang, Lumei
    [J]. ENERGY AND BUILDINGS, 2018, 173 : 239 - 251