Interpretation of ongoing thermal response tests of vertical (BHE) borehole heat exchangers with predictive uncertainty based stopping criterion

被引:9
|
作者
Poulsen, S. E. [1 ]
Alberdi-Pagola, M. [1 ]
机构
[1] VIA Univ Coll, Dept Civil Engn Res & Dev, DK-8700 Horsens, Denmark
关键词
Thermal response test; Testing time; Numerical model; Stopping criterion; Borehole heat exchanger; Predictive uncertainty; TEMPERATURE;
D O I
10.1016/j.energy.2015.03.133
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper presents a method for analyzing and establishing a stopping criterion for ongoing (TRT) thermal response tests of vertical (BHE) borehole heat exchangers. The predictive uncertainty of the late-time BHE fluid temperature (50 h) forms the basis for determining the time after which further temperature measurements do not significantly improve the calibration of the numerical borehole model. The method relies solely on measured fluid temperatures and can, in principle, be generalized to different BHE geometries and configurations. The method is applied to synthetic and actual TRTs of single and double U BHEs. Predictive uncertainty of the late-time fluid temperature is comparable to measurement uncertainty after 12-28 h of testing at which reliable estimates of soil thermal conductivity and borehole thermal resistance are obtained. Minimum testing times are found to scale with borehole thermal resistance in the synthetic tests. It is further demonstrated that for actual tests, ambient thermal disturbances bias estimates of soil thermal conductivity and inflate predictive uncertainty which increases minimum testing times. The method serves as a diagnostic tool for ongoing TRTs as well as a means to minimize testing times which has potential implications for the associated cost and logistics of field operations. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:157 / 167
页数:11
相关论文
共 25 条
  • [1] RECOVERY TIMES AFTER THERMAL RESPONSE TESTS ON VERTICAL BOREHOLE HEAT EXCHANGERS
    Javed, S.
    Claesson, J.
    Ra, Beier
    [J]. 23RD IIR INTERNATIONAL CONGRESS OF REFRIGERATION, 2011, 23 : 2034 - +
  • [2] Method of Averaging the Effective Thermal Conductivity Based on Thermal Response Tests of Borehole Heat Exchangers
    Sapinska-Sliwa, Aneta
    Sliwa, Tomasz
    Twardowski, Kazimierz
    Szymski, Krzysztof
    Gonet, Andrzej
    Zuk, Pawel
    [J]. ENERGIES, 2020, 13 (14)
  • [3] A New Method Based on Thermal Response Tests for Determining Effective Thermal Conductivity and Borehole Resistivity for Borehole Heat Exchangers
    Sapinska-Sliwa, Aneta
    Rosen, Marc A.
    Gonet, Andrzej
    Kowalczyk, Joanna
    Sliwa, Tomasz
    [J]. ENERGIES, 2019, 12 (06)
  • [4] Insights into parameter estimation for thermal response tests on borehole heat exchangers
    Beier, Richard A.
    [J]. SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2019, 25 (08) : 947 - 962
  • [5] Thermal response tests on deep borehole heat exchangers with geothermal gradient
    Beier, Richard A.
    [J]. APPLIED THERMAL ENGINEERING, 2020, 178
  • [6] Deconvolution and convolution methods for thermal response tests on borehole heat exchangers
    Beier, Richard A.
    [J]. GEOTHERMICS, 2020, 86
  • [7] The simplified calculation method of the thermal response radius for vertical borehole heat exchangers
    [J]. Zhang, Zhengwei (zwzhang10@126.com), 1600, Science Press (37):
  • [8] Use of temperature derivative to analyze thermal response tests on borehole heat exchangers
    Beier, Richard A.
    [J]. APPLIED THERMAL ENGINEERING, 2018, 134 : 298 - 309
  • [9] Distributed thermal response tests on pipe-in-pipe borehole heat exchangers
    Acuna, Jose
    Palm, Bjorn
    [J]. APPLIED ENERGY, 2013, 109 : 312 - 320
  • [10] Parameter estimation of in-situ thermal response tests for borehole ground heat exchangers
    Li, Min
    Lai, Alvin C. K.
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2012, 55 (9-10) : 2615 - 2624