Distributed thermal response tests on pipe-in-pipe borehole heat exchangers

被引:120
|
作者
Acuna, Jose [1 ]
Palm, Bjorn [1 ]
机构
[1] Royal Inst Technol, KTH, S-10044 Stockholm, Sweden
关键词
Borehole thermal resistance; Borehole heat exchanger; Coaxial; Pipe-in-pipe; Distributed thermal response test; RESISTANCE;
D O I
10.1016/j.apenergy.2013.01.024
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Borehole Thermal Energy Storage systems typically use U-pipe Borehole Heat Exchangers (BHE) having borehole thermal resistances of at least 0.06 K m/W. Obviously, there is room for improvement in the U-pipe design to decrease these values. Additionally, there is a need for methods of getting more detailed knowledge about the performance of BHEs. Performing Distributed Thermal Response Tests (DTRT) on new proposed designs helps to fill this gap, as the ground thermal conductivity and thermal resistances in a BHE can be determined at many instances in the borehole thanks to distributed temperature measurements along the depth. In this paper, results from three heat injection DTRTs carried out on two coaxial pipe-in-pipe BHEs at different flow rates are presented for the first time. The tested pipe-in-pipe geometry consists of a central tube inserted into a larger external flexible pipe, forming an annular space between them. The external pipe is pressed to the borehole wall by applying a slight overpressure at the inside, resulting in good thermal contact and at the same time opening up for a novel method for measuring the borehole wall temperature in situ, by squeezing a fiber optic cable between the external pipe and the borehole wall. A reflection about how to calculate borehole thermal resistance in pipe-in-pipe BHEs is presented. Detailed fluid and borehole wall temperatures along the depth during the whole duration of the DTRTs allowed to calculate local and effective borehole thermal resistances and ground thermal conductivities. Local thermal resistances were found to be almost negligible as compared to U-pipe BHEs, and the effective borehole resistance equal to about 0.03 K m/W. The injected power was found to be almost evenly distributed along the depth. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:312 / 320
页数:9
相关论文
共 50 条
  • [1] Distributed thermal response tests on a multi-pipe coaxial borehole heat exchanger
    Acuna, Jose
    Mogensen, Palne
    Palm, Bjorn
    [J]. HVAC&R RESEARCH, 2011, 17 (06): : 1012 - 1029
  • [2] Thermal expansion of pipe-in-pipe systems
    Bokaian, A
    [J]. MARINE STRUCTURES, 2004, 17 (06) : 475 - 500
  • [3] Effective pipe-to-borehole thermal resistance for vertical ground heat exchangers
    Sharqawy, Mostafa H.
    Mokheimer, Esmail M.
    Badr, Hassan M.
    [J]. GEOTHERMICS, 2009, 38 (02) : 271 - 277
  • [4] Insights into parameter estimation for thermal response tests on borehole heat exchangers
    Beier, Richard A.
    [J]. SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2019, 25 (08) : 947 - 962
  • [5] Thermal response tests on deep borehole heat exchangers with geothermal gradient
    Beier, Richard A.
    [J]. APPLIED THERMAL ENGINEERING, 2020, 178
  • [6] Study on the best heat transfer rate in thermal response test experiments with coaxial and U-pipe borehole heat exchangers
    Morchio, Stefano
    Fossa, Marco
    Beier, Richard A.
    [J]. APPLIED THERMAL ENGINEERING, 2022, 200
  • [7] Deconvolution and convolution methods for thermal response tests on borehole heat exchangers
    Beier, Richard A.
    [J]. GEOTHERMICS, 2020, 86
  • [8] A field study on the application of distributed temperature sensing technology in thermal response tests for borehole heat exchangers
    Cao, Dingfeng
    Shi, Bin
    Zhu, Hong-Hu
    Wei, Guangqing
    Bektursen, Hainar
    Sun, Mengya
    [J]. BULLETIN OF ENGINEERING GEOLOGY AND THE ENVIRONMENT, 2019, 78 (06) : 3901 - 3915
  • [9] Buckling response of pipe-in-pipe systems subjected to bending
    Wang Z.
    Chen Z.
    Liu H.
    He Y.
    Ma K.
    [J]. Transactions of Tianjin University, 2015, 21 (06) : 492 - 500
  • [10] A field study on the application of distributed temperature sensing technology in thermal response tests for borehole heat exchangers
    Dingfeng Cao
    Bin Shi
    Hong-Hu Zhu
    Guangqing Wei
    Hainar Bektursen
    Mengya Sun
    [J]. Bulletin of Engineering Geology and the Environment, 2019, 78 : 3901 - 3915