Anti Corrosion Activity of CRF (Cardiac Risk Free) Drug for SS316L, Ni–Ti, and Ti-6Al-4V in Artificial Blood Plasma

被引:0
|
作者
Ajila Asirvatham
Delinta Devadoss
Ashok Kujur
A. Selvam
J. Nirmala Devi
S. John Mary
机构
[1] Loyola College,Department of Chemistry
[2] Loyola Institute of Frontier Energy,School of Medicine
[3] Loyola College,undefined
[4] Creighton University,undefined
来源
Chemistry Africa | 2024年 / 7卷
关键词
SS316L; Ni–Ti; Ti-6Al-4V; Electrochemical calculation; Passive films; Artificial blood plasma;
D O I
暂无
中图分类号
学科分类号
摘要
In artificial blood plasma, the electrochemical behavior of SS316L, Ni–Ti, and Ti-6Al-4V was assessed. 17–20% chromium, 13–15% nickel, 2–3% molybdenum, and trace amounts of other metals make up the composition of SS316L. 44% Titanium and 56% Nickel make up Ni–Ti. The chemical formula of Ti-6Al-4V consists primarily of titanium, with trace quantities of aluminium, vanadium, iron, and oxygen (up to 0.2%). They are frequently employed in medical implantation, particularly for inserting cardiovascular stents, due to their corrosion resistance, biocompatibility, high modulus of elasticity, and non-toxicity. Cardiac risk-free drug (CRF) is an organic cholesterol-lowering medication used by cardiac patients with stents to lower their body cholesterol. The corrosion inhibitory effect of the cardiac risk-free drug at various concentrations ranging from 50 to 150 ppm was investigated utilizing potentiodynamic polarization and electrochemical impedance spectroscopy. The Tafel slope proves the efficiency with higher linear polarisation resistance (LPR), corrosion current (Icorr) of 10.1881 × 105 Ω cm2, 3.834 × 10−5 A/cm2 respectively. Similarly, the charge transfer resistance (Rct) and double layer capacitance (Cdl) of the Nyquist plot are 1900 Ω cm2 and 0.836 × 10–9 F/cm2 respectively. With additional support provided by Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), and EDAX. The Inhibition Efficiency rises with increasing concentration and days, reaching a high of 99% at 150 ppm of CRF drug for 14 days on SS316L. Furthermore, it shows that adsorption on SS316L surfaces is the primary cause of the inhibitors' inhibition processes.
引用
收藏
页码:891 / 903
页数:12
相关论文
共 50 条
  • [31] The Effect of Coating Thickness on Corrosion Resistance of Hydroxyapatite Coated Ti6Al4V and 316L SS Implants
    B. Aksakal
    M. Gavgali
    B. Dikici
    Journal of Materials Engineering and Performance, 2010, 19 : 894 - 899
  • [32] Micro asperity-based fretting corrosion of CoCrMo, Ti-6Al-4V, and 316L SS: Assessment of an electrochemical and micro-mechanical model
    Mace, Annsley
    Gilbert, Jeremy L.
    TRIBOLOGY INTERNATIONAL, 2023, 180
  • [33] Evaluation of corrosion and tribocorrosion of plasma electrolytic oxidation treated Ti-6Al-4V alloy
    Jazi, M. R. Garsivaz
    Golozar, M. A.
    Raeissi, K.
    Fazel, M.
    SURFACE & COATINGS TECHNOLOGY, 2014, 244 : 29 - 36
  • [34] Ceramic dip coating on Ti-6Al-4V and 316l enhances biomechanical properties
    Aksakal, B
    Yildirim, OS
    Okur, A
    Gul, H
    Proceedings of the Third IASTED International Conference on BIOMECHANICS, 2005, : 284 - 288
  • [35] Study of Microstructure, Mechanical Properties, and Corrosion Behavior of As-Cast Ni-Ti and Ti-6Al-4V Alloys
    Elshaer, Ramadan N.
    Ibrahim, Khaled M.
    JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2023, 32 (17) : 7831 - 7845
  • [36] Study of Microstructure, Mechanical Properties, and Corrosion Behavior of As-Cast Ni-Ti and Ti-6Al-4V Alloys
    Ramadan N. Elshaer
    Khaled M. Ibrahim
    Journal of Materials Engineering and Performance, 2023, 32 : 7831 - 7845
  • [37] Corrosion mechanism of Ti-6Al-4V morse taper dental implants connected to 316 L stainless steel prosthetic abutment
    Berbel, Larissa Oliveira
    de Viveiros, Barbara Victoria Goncalves
    Micelli, Ana Ligia Piza
    Nigro, Frederico
    Rossi, Jesualdo Luiz
    Costa, Isolda
    MATERIALS TODAY COMMUNICATIONS, 2022, 33
  • [38] Influence of laser surface modification on corrosion behavior of stainless steel 316L and Ti-6Al-4V in simulated biofluid
    Singh, R
    Martin, M
    Dahotre, NB
    SURFACE ENGINEERING, 2005, 21 (04) : 297 - 306
  • [39] Adsorption of Candida albicans on Ti-6Al-4V surface and its corrosion effects in artificial saliva
    Zeng, Feng
    Li, Yan
    Chen, KeXin
    Li, Guang
    Liu, Chang
    Wang, Lin
    Li, Lei
    Qu, Qing
    BIOELECTROCHEMISTRY, 2022, 148
  • [40] Corrosion Behavior of Cu/Ni Coatings on Ti-6Al-4V Alloy after Diffused Treatment
    王楠
    陈永楠
    LIU Shuangshuang
    ZHU Lixia
    朱世东
    ZHAO Yongqing
    ZHANG Long
    HAO Jianmin
    ZHANG Zhen
    WU Zhicheng
    JournalofWuhanUniversityofTechnology(MaterialsScience), 2020, 35 (01) : 215 - 222