Intra- and inter-rater reliability of ultrasound measures of the anterior cruciate ligament

被引:0
|
作者
Zachary A. Sievert
Hunter J. Bennett
Joshua T. Weinhandl
机构
[1] Old Dominion University,Department of Human Movement Sciences, 2016 Student Recreation Center
[2] The University of Tennessee,Department of Kinesiology, Recreation, and Sport Studies
来源
Journal of Ultrasound | 2021年 / 24卷
关键词
ACL; Ultrasound; Reliability; Anteromedial bundle;
D O I
暂无
中图分类号
学科分类号
摘要
Diagnostic ultrasound has accurately and reliably been utilized by clinicians to determine ACL morphology at the tibial insertion site, specifically measuring the entire ACL diameter, the anteromedial bundle (AM), and the posterolateral bundle. However, intra- and inter-rater reliability of these measures in a research setting is unknown. The purpose of this study was to determine intra- and inter-rater reliability of ultrasound measures of ACL diameter and AM diameter in researchers with low-to-moderate ultrasound experience. We hypothesized that intra- and inter-rater reliability of ACL and AM diameters would reach acceptable levels, a minimal intraclass correlation (ICC) of 0.6 and a desired ICC of 0.8 with an α of 0.05 and β of 0.20. Fourteen volunteers participated in this study. During the ACL ultrasound measures, participants were seated with their knee flexed to at least 90°. Each rater recorded two images of both the right and left ACL and AM bundles. Next, participants were re-examined by rater one for intra-rater reliability analyses. Two-way random ICCs were conducted for intra-rater (between sessions) and inter-rater reliability for both the full ACL and the AM bundle diameters. Standard errors between sessions for Rater 1’s AM bundle and ACL diameters were less than 0.03 cm. Intra-rater reliability was higher in AM bundles compared to full ACL, 0.76 versus 0.59, respectively. Standard errors between Rater 1 and Rater 2 were less than 0.03 cm. Inter-rater reliability was higher in AM bundles compared to full ACL, 0.71 versus 0.41, respectively. The results of the study indicate researchers with low-to-moderate training with ultrasound measures can locate and measure the ACL, but with greater reliability using the AM.
引用
收藏
页码:49 / 55
页数:6
相关论文
共 50 条
  • [21] Reproducibility of radiomics quality score: an intra- and inter-rater reliability study
    Akinci D'Antonoli, Tugba
    Cavallo, Armando Ugo
    Vernuccio, Federica
    Stanzione, Arnaldo
    Klontzas, Michail E.
    Cannella, Roberto
    Ugga, Lorenzo
    Baran, Agah
    Fanni, Salvatore Claudio
    Petrash, Ekaterina
    Ambrosini, Ilaria
    Cappellini, Luca Alessandro
    van Ooijen, Peter
    Kotter, Elmar
    Pinto dos Santos, Daniel
    Cuocolo, Renato
    EUROPEAN RADIOLOGY, 2024, 34 (04) : 2791 - 2804
  • [22] INTRA- AND INTER-RATER RELIABILITY OF THE SELECTIVE FUNCTIONAL MOVEMENT ASSESSMENT (SFMA)
    Glaws, Kathryn R.
    Juneau, Christopher M.
    Becker, Lindsay C.
    Di Stasi, Stephanie L.
    Hewett, Timothy E.
    INTERNATIONAL JOURNAL OF SPORTS PHYSICAL THERAPY, 2014, 9 (02): : 195 - 207
  • [23] Reproducibility of radiomics quality score: an intra- and inter-rater reliability study
    Tugba Akinci D’Antonoli
    Armando Ugo Cavallo
    Federica Vernuccio
    Arnaldo Stanzione
    Michail E. Klontzas
    Roberto Cannella
    Lorenzo Ugga
    Agah Baran
    Salvatore Claudio Fanni
    Ekaterina Petrash
    Ilaria Ambrosini
    Luca Alessandro Cappellini
    Peter van Ooijen
    Elmar Kotter
    Daniel Pinto dos Santos
    Renato Cuocolo
    European Radiology, 2024, 34 : 2791 - 2804
  • [24] Intra- and inter-rater reliability of jumping mechanography muscle function assessments
    Matheson, L. A.
    Duffy, S.
    Maroof, A.
    Gibbons, R.
    Duffy, C.
    Roth, J.
    JOURNAL OF MUSCULOSKELETAL & NEURONAL INTERACTIONS, 2013, 13 (04) : 480 - 486
  • [25] Clinical evaluation of the anterior translation of glenohumeral joint using ultrasonography: an intra- and inter-rater reliability study
    Joseph, Leonard H.
    Hussain, Rizuana I.
    Pirunsan, Ubon
    Naicker, Amaramalar S.
    Htwe, Ohnmar
    Paungmali, Aatit
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2014, 48 (02) : 169 - 174
  • [26] Inter-rater reliability of an ultrasound protocol to evaluate the anterolateral ligament of the knee
    Kandel, Michel
    Cattrysse, Erik
    De Maeseneer, Michel
    Lenchik, Leon
    Paantjens, Marc
    Leeuw, Marco
    JOURNAL OF ULTRASONOGRAPHY, 2019, 19 (78) : 181 - 186
  • [27] Inter-rater reliability of Rolimeter measurements between anterior cruciate ligament injured and normal contra lateral knees
    Papandreou, MG
    Antonogiannakis, E
    Karabalis, C
    Karliaftis, K
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2005, 13 (07) : 592 - 597
  • [28] Intra- and inter-rater reliability of urethral mobility measurement by ultrasound in women: a cross-section study
    Ana Jessica dos Santos Sousa
    Juliana Falcão Padilha
    Jordana Barbosa da Silva
    Humberto Sadanobu Hirakawa
    Enio Júnior Seidel
    Patricia Driusso
    International Urogynecology Journal, 2021, 32 : 119 - 125
  • [29] Inter-rater reliability of Rolimeter measurements between anterior cruciate ligament injured and normal contra lateral knees
    Maria G. Papandreou
    Emmanuel Antonogiannakis
    Christos Karabalis
    Konstantinos Karliaftis
    Knee Surgery, Sports Traumatology, Arthroscopy, 2005, 13 : 592 - 597
  • [30] Intra- and inter-rater reliability of urethral mobility measurement by ultrasound in women: a cross-section study
    dos Santos Sousa, Ana Jessica
    Padilha, Juliana Falcao
    da Silva, Jordana Barbosa
    Hirakawa, Humberto Sadanobu
    Junior Seidel, Enio
    Driusso, Patricia
    INTERNATIONAL UROGYNECOLOGY JOURNAL, 2021, 32 (01) : 119 - 125