Transient time flow measurement in arterial grafts

被引:2
|
作者
Leviner, Dror B. [1 ,2 ]
Puskas, John D. [3 ]
Taggart, David P. [4 ]
机构
[1] Carmel Hosp, Dept Cardiac Surg, Haifa, Israel
[2] Technion Israel Inst Technol, Ruth & Baruch Rappaport Fac Med, Haifa, Israel
[3] Emory Univ, Sch Med, Devis Cardiothorac Surg, Atlanta, GA USA
[4] Univ Oxford, John Radcliffe Hosp, Dept Cardiac Surg, Oxford, England
关键词
LONG-TERM; FOLLOW-UP; ON-PUMP; CORONARY; RESERVE; OUTCOMES; SURVIVAL;
D O I
10.1186/s13019-024-02670-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Coronary artery bypass grafting (CABG) is one of the foundations of treatment for coronary artery disease. While it has improved substantially since its inception more than 50 years ago, including a rising use of multiple arterial grafting, intraoperative quality assessment is yet to be disseminated as an integral part of the procedure. Herein we review the fundamentals of intraoperative quality assessment in CABG using transient time flow measurement (TTFM) with a focus on its use in arterial grafting.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Transit-time flow characteristics of in situ right gastroepiploic arterial grafts in coronary artery bypass grafting
    Takami, Yoshiyuki
    Tajima, Kazuyoshi
    Terazawa, Sachie
    Okada, Noritaka
    Fujii, Kei
    Sakai, Yoshimasa
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 138 (03): : 669 - 673
  • [42] SYSTOLIC-TIME INTERVALS DERIVED FROM DOPPLER MEASUREMENT OF TEMPORAL ARTERIAL FLOW
    SPODICK, DH
    AMERICAN JOURNAL OF CARDIOLOGY, 1982, 49 (05): : 1377 - 1378
  • [43] Simultaneous Measurement of Cerebral Blood Flow and Arterial Transit Time for Sickle Cell Disease
    Qin, Qin
    Li, Wenbo
    Liu, Dexiang
    Strouse, John J.
    BLOOD, 2016, 128 (22)
  • [44] Intraoperative Transit-Time Flow Measurement Is Not Altered in Venous Bypass Grafts Covered by the eSVS Mesh
    Emery, Robert W.
    Solien, Eric
    INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2013, 8 (01) : 37 - 41
  • [45] Operative strategy enhancement following transit-time flow measurement in coronary artery bypass grafts
    Maruszewski, Marcin
    Borowicz, Marcin
    Kubacki, Krzysztof
    Zembala, Marian
    KARDIOCHIRURGIA I TORAKOCHIRURGIA POLSKA, 2006, 3 (04): : 367 - 371
  • [46] Quantitative measurement of the ratio of bronchial arterial blood flow to pulmonary arterial blood flow
    Matsunaga, K.
    Yanagawa, M.
    Shimosegawa, E.
    Hatazawa, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S327 - S327
  • [47] TRANSIENT BEHAVIOR OF ARTERIAL SYSTEMS IN RESPONSE TO FLOW PULSES
    YOUNG, ED
    BULLETIN OF MATHEMATICAL BIOPHYSICS, 1968, 30 (03): : 359 - &
  • [48] TRANSIENT STOP-FLOW ARM ARTERIAL-VENOUS EQUILIBRIUM PRESSURE MEASUREMENT: DETERMINATION OF PRECISION OF THE TECHNIQUE
    Aya, H. D.
    Rhodes, A.
    Fletcher, N.
    Grounds, M.
    Cecconi, M.
    INTENSIVE CARE MEDICINE, 2014, 40 : S46 - S46
  • [49] Transient stop-flow arm arterial-venous equilibrium pressure measurement: determination of precision of the technique
    Aya, Hollmann D.
    Rhodes, Andrew
    Fletcher, Nick
    Grounds, R. Michael
    Cecconi, Maurizio
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2016, 30 (01) : 55 - 61
  • [50] In Vivo Validation of Numerical Prediction of Blood Flow in Arterial Bypass Grafts
    Joy P. Ku
    Mary T. Draney
    Frank R. Arko
    W. Anthony Lee
    Frandics P. Chan
    Norbert J. Pelc
    Christopher K. Zarins
    Charles A. Taylor
    Annals of Biomedical Engineering, 2002, 30 : 743 - 752