Intraoperative Transit-Time Flow Measurement Is Not Altered in Venous Bypass Grafts Covered by the eSVS Mesh

被引:0
|
作者
Emery, Robert W. [1 ]
Solien, Eric [2 ]
机构
[1] St Josephs Hosp, Cardiovasc Surg, St Paul, MN USA
[2] Kips Bay Med Inc, Minneapolis, MN USA
关键词
eSVS Mesh; Nitinol wire; Dobutamine;
D O I
10.1097/imi.0b013e31828e5d1e
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: The aim of this study was to determine whether the eSVS Mesh interferes with transit-time flow measurement (TTFM) assessing intraoperative coronary vein graft patency. Methods: In four swine undergoing off-pump bypass grafting to the anterior descending coronary artery, five TTFMs were sequentially obtained on meshed and bare grafts at baseline and under Dobutamine stress at five separate locations on the graft in each animal. The Medistim VeriQ was used for TTFM. The grafts were examined for patency after the swine were killed. Results: There was no difference in hemodynamics or TTFM either at baseline or under Dobutamine stress between the eSVS Mesh covered and uncovered grafts. Dobutamine, however, significantly increased hemodynamics and graft flow parameters measured from baseline. Conclusions: The eSVS Mesh does not interfere with Doppler flow measurement in covered coronary vein grafts.
引用
收藏
页码:37 / 41
页数:5
相关论文
共 50 条
  • [1] External stenting of saphenous vein bypass grafts does not affect intraoperative transit-time flow measurement
    Burak Can Depboylu
    Patrick O Myers
    Mootoosamy Parmeseeven
    Jalal Jolou
    Kamran Ahmadov
    Saziye Karaca
    Marck Licker
    Afksendiyos Kalangos
    Mustafa Cikirikcioglu
    Journal of Cardiothoracic Surgery, 10 (Suppl 1)
  • [2] Evaluation of coronary artery bypass grafts by intraoperative transit time flow measurement
    Pankaj Goel
    S Dubey
    A Makker
    VM Kohli
    Indian Journal of Thoracic and Cardiovascular Surgery, 2003, 19 (2) : 108 - 112
  • [3] Measuring Intraoperative Transit-Time Flow: Arterial, Venous and Sequential Grafts, and New Research Areas
    Piciche, Marco
    HEART LUNG AND CIRCULATION, 2019, 28 (02): : E2 - E2
  • [4] A randomized comparison of intraoperative indocyanine green angiography and transit-time flow measurement to detect technical errors in coronary bypass grafts
    Desai, Nimesh D.
    Miwa, Senri
    Kodama, David
    Koyama, Taadaki
    Cohen, Gideon
    Pelletier, Marc P.
    Cohen, Eric A.
    Christakis, George T.
    Goldman, Bernard S.
    Fremes, Stephen E.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2006, 132 (03): : 585 - 594
  • [5] Intraoperative flow measurement of coronary bypass grafts using the ultrasound transit time flowmeter
    Voigtländer, T
    Dahm, M
    Kreitner, KF
    Frick, C
    Wittlinger, T
    Nowak, B
    Kalden, P
    Hake, U
    Mayer, E
    Bickel, C
    Meyer, J
    ZEITSCHRIFT FUR KARDIOLOGIE, 1999, 88 (10): : 773 - 779
  • [6] Operative strategy enhancement following transit-time flow measurement in coronary artery bypass grafts
    Maruszewski, Marcin
    Borowicz, Marcin
    Kubacki, Krzysztof
    Zembala, Marian
    KARDIOCHIRURGIA I TORAKOCHIRURGIA POLSKA, 2006, 3 (04): : 367 - 371
  • [7] External Saphenous Vein Support Mesh Does Not Interfere With Transit-Time Flow Measurement on Venous Coronary Bypass Conduit Clinical Confirmation
    Mootoosamy, Parmeseeven
    Jolou, Jalal
    Myers, Patrick O.
    Walpoth, Beat H.
    Kalangos, Afksendiyos
    Cikirikcioglu, Mustafa
    INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2016, 11 (01) : 70 - 72
  • [8] Intraoperative Fluorescence Imaging After Transit-Time Flow Measurement During Coronary Artery Bypass Grafting
    Kuroyanagi, Satoshi
    Asai, Tohru
    Suzuki, Tomoaki
    INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2012, 7 (06) : 435 - 440
  • [9] Intraoperative evaluation of coronary anastomosis by transit-time ultrasonic flow measurement
    Morota, T
    Duhaylongsod, FG
    Burfeind, WR
    Huang, CT
    ANNALS OF THORACIC SURGERY, 2002, 73 (05): : 1446 - 1450
  • [10] Transit-time flow measurement is essential in coronary artery bypass grafting
    Leong, DKH
    Ashok, V
    Nishkantha, A
    Shan, YH
    Sim, EKW
    ANNALS OF THORACIC SURGERY, 2005, 79 (03): : 854 - 858