Accuracy and reliability of maxillary digital model (MDM) superimposition in evaluating teeth movement in adults compared with CBCT maxillary superimposition

被引:0
|
作者
Yichen Pan
Xin Wang
Fanfan Dai
Gui Chen
Tianmin Xu
机构
[1] School and Hospital of Stomatology,Department of Orthodontics
[2] School and Hospital of Stomatology,Second Dental Center
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Superimposition of 3D maxillary digital dental models of different time points based on palatal vault region has been used to evaluate tooth movement during orthodontic treatment. This study evaluated the accuracy and reliability of 3D maxillary digital model (MDM) superimposition in adults by comparing it with CBCT maxillary superimposition. In CBCT maxillary superimposition, voxel-based superimposition was firstly conducted, and MDMs were matched with corresponding CBCT models (CBCT-MDM superimposition). MDM superimposition (palatal vault regional superimposition) were performed on another pair of pre- and posttreatment MDMs. The position and orientation of upper first molars (U6s) and upper central incisors (U1s) on the posttreatment MDMs were compared to assess the accuracy of the MDM superimposition methods. The reliability was validated in both MDM superimposition and CBCT maxillary superimposition. In terms of accuracy, the average linear deviations in U6 and U1 positions were less than ± 0.3 mm, the average angular deviations of U6s and U1s were less than ± 0.2°, both have no significant difference from zero. The ICCs for MDM superimposition ranged from 0.85 to 0.99. The ICCs for CBCT-MDM superimposition were larger than 0.99 in all items. MDM superimposition was an efficient, accurate and reliable method for evaluating teeth movement in adults, although its reliability is slightly lower than CBCT maxillary superimposition.
引用
收藏
相关论文
共 11 条
  • [1] Accuracy and reliability of maxillary digital model (MDM) superimposition in evaluating teeth movement in adults compared with CBCT maxillary superimposition
    Pan, Yichen
    Wang, Xin
    Dai, Fanfan
    Chen, Gui
    Xu, Tianmin
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [2] Superimposition of maxillary digital models using the palatal rugae: Does ageing affect the reliability?
    Garib, Daniela
    Miranda, Felicia
    Yatabe, Marilia S.
    Pereira Lauris, Jose Roberto
    Massaro, Camila
    McNamara, James A.
    Kim-Berman, Hera
    Janson, Guilherme
    Behrents, Rolf G.
    Cevidanes, Lucia H. S.
    Ruellas, Antonio Carlos de Oliveira
    ORTHODONTICS & CRANIOFACIAL RESEARCH, 2019, 22 (03) : 183 - 193
  • [3] Accuracy of maxillary molar distalization with clear aligners in three-dimension: a retrospective study based on CBCT superimposition
    Qiang, Ruyue
    Zhang, Haolin
    Xu, Yuerong
    Zhang, Xu
    Jin, Fang
    Jin, Zuolin
    Qin, Wen
    Gao, Jie
    CLINICAL ORAL INVESTIGATIONS, 2025, 29 (02)
  • [4] Measuring Maxillary Posterior Tooth Movement: A Model Assessment using Palatal and Dental Superimposition
    Alwafi, Abdulraheem A.
    Panther, Scott
    Lo, Angela
    Yen, Edwin H.
    Zou, Bingshuang
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2024, (204):
  • [5] Quantifying maxillary anterior tooth movement in digital orthodontics: Does the choice of the superimposition software matter?
    Adel, Samar M.
    Vaid, Nikhilesh R.
    El-Harouni, Nadia
    Kassem, Hassan
    Park, Jae Hyun
    Zaher, Abbas R.
    JOURNAL OF THE WORLD FEDERATION OF ORTHODONTISTS, 2023, 12 (05) : 187 - 196
  • [6] Evaluation of the reliability of palatal rugae as a reference area in digital superimposition after slow maxillary expansion treatment
    Gokmen, Sule
    Topsakal, Kubra Gulnur
    Duran, Gokhan Serhat
    Gorgulu, Serkan
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2025, 167 (04) : 454 - 463
  • [7] Effects of Type and Amount of Orthodontic Tooth Movement on Digital Model Superimposition Accuracy
    Camci, Hasan
    Salmanpour, Farhad
    TURKISH JOURNAL OF ORTHODONTICS, 2021, 34 (04) : 220 - 226
  • [8] A novel method for superimposition and measurements on maxillary digital 3D models-studies on validity and reliability
    Ganzer, Niels
    Feldmann, Ingalill
    Liv, Per
    Bondemark, Lars
    EUROPEAN JOURNAL OF ORTHODONTICS, 2018, 40 (01) : 45 - 51
  • [9] Accuracy of intraoral digital radiography in assessing maxillary Sinus-Root relationship compared to CBCT
    Eid, Esraa Ahmed
    El-Badawy, Fatma Mostafa
    Hamed, Walaa Mohamed
    SAUDI DENTAL JOURNAL, 2022, 34 (05) : 397 - 403
  • [10] Accuracy and reliability of mandibular digital model superimposition based on the morphological characteristics of vessels in extraction adult patients
    Yaozheng Hu
    Mengyu Zheng
    Jin Chen
    Chenlin Guo
    Jianming Chen
    BMC Oral Health, 24