Superimposition of maxillary digital models using the palatal rugae: Does ageing affect the reliability?

被引:26
|
作者
Garib, Daniela [1 ,2 ]
Miranda, Felicia [1 ]
Yatabe, Marilia S. [3 ]
Pereira Lauris, Jose Roberto [4 ]
Massaro, Camila [1 ]
McNamara, James A. [3 ]
Kim-Berman, Hera [3 ]
Janson, Guilherme [1 ]
Behrents, Rolf G. [5 ]
Cevidanes, Lucia H. S. [3 ]
Ruellas, Antonio Carlos de Oliveira [3 ]
机构
[1] Univ Sao Paulo, Bauru Dent Sch, Dept Orthodont, Bauru, Brazil
[2] Univ Sao Paulo, Hosp Rehabil Craniofacial Anomalies, Bauru, Brazil
[3] Univ Michigan, Sch Dent Med, Dept Orthodont & Pediat Dent, Ann Arbor, MI 48109 USA
[4] Univ Sao Paulo, Bauru Dent Sch, Dept Publ Hlth, Bauru, Brazil
[5] St Louis Univ, Ctr Adv Dent Educ, Orthodont Program, St Louis, MO 63103 USA
基金
巴西圣保罗研究基金会;
关键词
ageing; dental models; reproducibility of results; VALIDITY; LANDMARKS; STABILITY; ACCURACY;
D O I
10.1111/ocr.12309
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Structured AbstractObjectives The aim of this study was to evaluate the reliability of 3-dimensional maxillary dental changes using two methods of digital model superimposition. Setting and Sample Population The Department of Orthodontics of Bauru Dental School, University of Sao Paulo and University of Michigan Craniofacial Growth Center. Fifteen subjects with normal occlusion. Material & Methods The sample was composed of digital study models of 15 normal occlusion subjects taken at 13 (T1), 18 (T2) and 60 years of age (T3). Using the software SlicerCMF 3.1, superimposition (registration) was conducted using 9 landmarks placed on the incisive papilla, second and third palatal rugae and 10 mm distal to the third palatal rugae. Two registration methods were compared: landmarks (LA) and regions of interest (ROI). Three-dimensional changes of landmarks on the buccal cusp tip of posterior teeth bilaterally and the incisal edge of the right central incisor were measured by three examiners. Intraclass correlation coefficients and Bland-Altman method evaluated intra- and inter-examiner agreements. Results Good or excellent intra-examiner agreement was found for T1-T2 and T2-T3 measurements using both registration methods. Inter-examiner agreements were good to excellent for T1-T2 measurements and poor to fair for most T2-T3 measurements. Mean T1-T2 differences were less than 0.5 mm for most measurements. Conclusion Maxillary digital dental models of patients with normal occlusion superimposed on palatal rugae showed an adequate reliability for a 5-year interval comparison using landmarks or regions of interest. Lower than acceptable reproducibility using both superimposition methods was found for a 40-year interval comparison.
引用
收藏
页码:183 / 193
页数:11
相关论文
共 50 条
  • [1] Evaluation of the reliability of palatal rugae as a reference area in digital superimposition after slow maxillary expansion treatment
    Gokmen, Sule
    Topsakal, Kubra Gulnur
    Duran, Gokhan Serhat
    Gorgulu, Serkan
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2025, 167 (04) : 454 - 463
  • [2] Accuracy and reliability of palatal superimposition of three-dimensional digital models
    Choi, Dong-Soon
    Jeong, Young-Mok
    Jang, Insan
    Jost-Brinkmann, Paul George
    Cha, Bong-Kuen
    ANGLE ORTHODONTIST, 2010, 80 (04) : 685 - 691
  • [3] Analysis of the Morphological Characteristics of the Palatal Rugae for Three-Dimensional Superimposition of Digital Models in Korean Subjects
    Choi, Sung-Hwan
    Koh, Kyongmin
    Lee, Kee-Joon
    Hwang, Chung-Ju
    Cha, Jung-Yul
    BIOMED RESEARCH INTERNATIONAL, 2018, 2018
  • [4] Registration of serial maxillary models via the weighted rugae superimposition method
    Abdi, A. H.
    Nouri, M.
    ORTHODONTICS & CRANIOFACIAL RESEARCH, 2017, 20 (02) : 79 - 84
  • [5] Validity and reliability of three-dimensional palatal superimposition of digital dental models
    Talaat, Sameh
    Kaboudan, Ahmed
    Bourauel, Christoph
    Ragy, Nivine
    Kula, Katherine
    Ghoneima, Ahmed
    EUROPEAN JOURNAL OF ORTHODONTICS, 2017, 39 (04) : 365 - 370
  • [6] Assessment of different 3D Superimposition Techniques of serial digital Maxillary Models using palatal Structures
    Schultze, Lara
    INFORMATIONEN AUS ORTHODONTIE UND KIEFERORTHOPAEDIE, 2018, 50 (01): : 6 - 8
  • [7] Analysis of the palatal rugae following Rapid Maxillary Expansion (RME) by using a 3D-3D superimposition procedure
    Ugolini, Alessandro
    Cossellu, Gianguido
    Rusconi, Francesca
    De Luca, Stefano
    AUSTRALIAN JOURNAL OF FORENSIC SCIENCES, 2023, 55 (02) : 191 - 202
  • [8] Validity of palatal superimposition of 3-dimensional digital models in cases treated with rapid maxillary expansion and maxillary protraction headgear
    Choi, Jin-Il
    Cha, Bong-Kuen
    Jost-Brinkmann, Paul-Georg
    Choi, Dong-Soon
    Jang, In-San
    KOREAN JOURNAL OF ORTHODONTICS, 2012, 42 (05) : 235 - 241
  • [9] Assessment of the Stability of the Palatal Rugae in a 3D-3D Superimposition Technique Following Slow Maxillary Expansion (SME)
    Valentina Lanteri
    Gianguido Cossellu
    Marco Farronato
    Alessandro Ugolini
    Rosalia Leonardi
    Francesca Rusconi
    Stefano De Luca
    Roberto Biagi
    Cinzia Maspero
    Scientific Reports, 10
  • [10] Accuracy and reliability of maxillary digital model (MDM) superimposition in evaluating teeth movement in adults compared with CBCT maxillary superimposition
    Pan, Yichen
    Wang, Xin
    Dai, Fanfan
    Chen, Gui
    Xu, Tianmin
    SCIENTIFIC REPORTS, 2020, 10 (01)