Calibration of the Irradiance Responsivity of a Filter Radiometer for T Measurement at NIM

被引:0
|
作者
X. Lu
Z. Yuan
X. Hao
Y. Lin
J. Yang
机构
[1] National Institute of Metrology,
[2] Beijing University of Chemical Technology,undefined
来源
关键词
Filter radiometer; Monochromator; Spectral responsivity; Thermodynamic temperature;
D O I
暂无
中图分类号
学科分类号
摘要
At the National Institute of Metrology of China (NIM), silicon photodiode-based narrow-band interference filter radiometers (FRs) have been designed for the radiometric determination of the thermodynamic temperature. The FR calibrations were performed on a new spectral comparator with a trap detector which was calibrated against the cryogenic radiometer at several discrete laser lines. The new spectral comparator is constructed from two grating monochromators assembled to give lower stray light and higher transmitted flux. Applying a transmittance measurement of the filter in the out-of-band region and careful control of the temperature, the irradiance responsivity of a 633 nm centered FR has been obtained over a dynamic range of nearly eight decades in the wavelength range from 450 nm to 1200 nm. The relative standard uncertainty of the responsivity is also analyzed and estimated to be less than 7 × 10−4 at the 1 σ level.
引用
收藏
页码:278 / 284
页数:6
相关论文
共 50 条
  • [1] Calibration of the Irradiance Responsivity of a Filter Radiometer for T Measurement at NIM
    Lu, X.
    Yuan, Z.
    Hao, X.
    Lin, Y.
    Yang, J.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2011, 32 (1-2) : 278 - 284
  • [2] A Comparison of Irradiance Responsivity and Thermodynamic Temperature Measurement between PTB and NIM
    Lu, X.
    Anhalt, K.
    Taubert, R. D.
    Yuan, Z.
    TEMPERATURE: ITS MEASUREMENT AND CONTROL IN SCIENCE AND INDUSTRY, VOL 8, 2013, 1552 : 728 - 733
  • [3] Calibration of broadband ultraviolet detectors by measurement of spectral irradiance responsivity
    Envall, Jouni
    Karha, Petri
    Ikonen, Erkki
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (06):
  • [4] Comparison of filter radiometer spectral responsivity with the NIST spectral-irradiance and illuminance scales
    Tsai, BK
    Johnson, BC
    Saunders, RD
    Cromer, CL
    METROLOGIA, 1996, 32 (06) : 473 - 477
  • [5] Spectral irradiance measurement and actinic radiometer calibration for UV water disinfection
    Sperfeld, Peter
    Barton, Bettina
    Pape, Sven
    Towara, Anna-Lena
    Eggers, Jutta
    Hopfenmueller, Gabriel
    METROLOGIA, 2014, 51 (06) : S282 - S288
  • [6] Radiometer calibration methods and resulting irradiance differences
    Habte, Aron
    Sengupta, Manajit
    Andreas, Afshin
    Reda, Ibrahim
    Robinson, Justin
    PROGRESS IN PHOTOVOLTAICS, 2017, 25 (07): : 614 - 622
  • [7] MULTICHANNEL RADIOMETER MEASUREMENT OF SOLAR IRRADIANCE
    DRUMMOND, AJ
    HICKEY, JR
    SCHOLES, WJ
    LAUE, EG
    JOURNAL OF SPACECRAFT AND ROCKETS, 1967, 4 (09) : 1200 - &
  • [8] Development of a new Controller for Absolute Cavity Radiometer for cavity calibration and solar irradiance measurement
    Singh, Ajay
    Perry, Matthew
    2016 IEEE 43RD PHOTOVOLTAIC SPECIALISTS CONFERENCE (PVSC), 2016, : 1013 - 1015
  • [9] PERFORMANCE OF A MULTI-WAVELENGTH FILTER RADIOMETER FOR SPECTRAL IRRADIANCE MEASUREMENT IN THE NEAR IR
    Liu, Yuanjie
    Xu, Gan
    Huang, Xuebo
    Manoocheri, Farshid
    Ikonen, Erkki
    LIGHT & ENGINEERING, 2011, 19 (01): : 61 - 69
  • [10] Responsivity calibration methods for 365 nm irradiance meters
    Larason, TC
    Brown, SW
    Eppeldauer, GP
    Lykke, KR
    2000 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 2000, : 261 - 262