Spectral irradiance measurement and actinic radiometer calibration for UV water disinfection

被引:3
|
作者
Sperfeld, Peter [1 ,2 ]
Barton, Bettina [1 ,2 ]
Pape, Sven [1 ,2 ]
Towara, Anna-Lena [1 ,2 ]
Eggers, Jutta [3 ]
Hopfenmueller, Gabriel [4 ]
机构
[1] Phys Tech Bundesanstalt, Braunschweig, Germany
[2] Phys Tech Bundesanstalt, Berlin, Germany
[3] DVGW Technol Zentrum Wasser, Karlsruhe, Germany
[4] Sglux SolGel Technol GmbH, Berlin, Germany
关键词
radiometery; UV water disinfection; microbicidal irradiance; actinic radiometer; UV lamps; UV-C;
D O I
10.1088/0026-1394/51/6/S282
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In a joint project, sglux and PTB investigated and developed methods and equipment to measure the spectral and weighted irradiance of high-efficiency UV-C emitters used in water disinfection plants. A calibration facility was set up to calibrate the microbicidal irradiance responsivity of actinic radiometers with respect to the weighted spectral irradiance of specially selected low-pressure mercury and medium-pressure mercury UV lamps. To verify the calibration method and to perform on-site tests, spectral measurements were carried out directly at water disinfection plants in operation. The weighted microbicidal irradiance of the plants was calculated and compared to the measurements of various actinic radiometers.
引用
收藏
页码:S282 / S288
页数:7
相关论文
共 50 条
  • [1] Spectral irradiance calibration of space remote sensing spectral radiometer in range of UV and VUV
    Huang, Yu
    Wang, Shu-Rong
    Zhang, Zhen-Duo
    Lin, Guan-Yu
    Li, Fu-Tian
    Guangzi Xuebao/Acta Photonica Sinica, 2007, 36 (SUPPL.): : 187 - 191
  • [2] Two procedures for the estimation of the uncertainty of spectral irradiance measurement for UV source calibration
    Obaton, A-F
    Lebenberg, J.
    Fischer, N.
    Guimier, S.
    Dubard, J.
    METROLOGIA, 2007, 44 (02) : 152 - 160
  • [3] Calibration of the Irradiance Responsivity of a Filter Radiometer for T Measurement at NIM
    Lu, X.
    Yuan, Z.
    Hao, X.
    Lin, Y.
    Yang, J.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2011, 32 (1-2) : 278 - 284
  • [4] Calibration of the Irradiance Responsivity of a Filter Radiometer for T Measurement at NIM
    X. Lu
    Z. Yuan
    X. Hao
    Y. Lin
    J. Yang
    International Journal of Thermophysics, 2011, 32 : 278 - 284
  • [5] Spectral attenuation of global and diffuse UV irradiance and actinic flux by clouds
    Mateos, D.
    di Sarra, A.
    Bilbao, J.
    Meloni, D.
    Pace, G.
    de Miguel, A.
    Casasanta, G.
    QUARTERLY JOURNAL OF THE ROYAL METEOROLOGICAL SOCIETY, 2015, 141 (686) : 109 - 113
  • [6] The Spectral Irradiance Monitor: Measurement equations and calibration
    Harder, JW
    Fontenla, J
    Lawrence, G
    Woods, T
    Rottman, G
    SOLAR PHYSICS, 2005, 230 (1-2) : 169 - 204
  • [7] The Spectral Irradiance Monitor: Measurement Equations and Calibration
    Jerald W. Harder
    Juan Fontenla
    George Lawrence
    Thomas Woods
    Gary Rottman
    Solar Physics, 2005, 230 : 169 - 204
  • [8] Calibration and characterization of UV sensors for water disinfection
    Larason, T
    Ohno, Y
    METROLOGIA, 2006, 43 (02) : S151 - S156
  • [9] An empirical method for the conversion of spectral UV irradiance measurements to actinic flux data
    Webb, AR
    Kift, R
    Thiel, S
    Blumthaler, M
    ATMOSPHERIC ENVIRONMENT, 2002, 36 (27) : 4397 - 4404
  • [10] Wavelength calibration of a solar spectral irradiance radiometer and validation by correlation photon coincidence counting
    Wang, Huili
    Hu, Youbo
    Zhai, Wenchao
    Li, Jianjun
    Zheng, Xiaobing
    SOLAR ENERGY, 2023, 264