Wavelength calibration of a solar spectral irradiance radiometer and validation by correlation photon coincidence counting

被引:1
|
作者
Wang, Huili [1 ,2 ,3 ]
Hu, Youbo [2 ]
Zhai, Wenchao [2 ]
Li, Jianjun [2 ]
Zheng, Xiaobing [2 ]
机构
[1] Univ Sci & Technol China, Sch Phys Sci, Dept Opt & Opt Engn, Hefei 230026, Peoples R China
[2] Chinese Acad Sci, Anhui Inst Opt & Fine Mech, Key Lab Opt Calibrat & Characterizat, Hefei 230031, Peoples R China
[3] Southwest Univ Sci & Technol, Sch Math & Phys, Mianyang 621010, Peoples R China
关键词
Solar spectral irradiance radiometer; Wavelength calibration; Correlation photon; Self-calibration; Coincidence measurement; MONITOR; SPECTROMETERS; ULTRAVIOLET; SCIENCE;
D O I
10.1016/j.solener.2023.112035
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Accurate wavelength calibration is the key to achieving accuracy observation of solar spectral irradiance. A wavelength calibration of solar spectral irradiance radiometer based on correlation photon radiation reference is proposed. The wavelengths of two channels of the solar spectral irradiance radiometer are calibrated by a Hg-Ar lamp and lasers. A collimating and focusing optics are designed to ensure that light can illuminate the slit vertically and without polarization. The optics can also keep the consistency of observing and self-calibration modes. The calibration equations of two channels are established. The wavelength deviations of two channels are-0.11 -0.07 nm and-0.085 -0.017 nm respectively. To validate the calibrated wavelength, channel 1 is selected as the inspection channel according to the spectral line number of the calibration lamp and the variation of the photon count rate. The motor position close to the calibration wavelength 763.511 nm is selected in channel 2, and the coincidence measurement is carried out to check the accuracy of wavelength calibration in channel 1. The deviation of wavelength around 408 nm is 1.139 nm. The experimental results show that the correlated photons self-calibration system can realize the calibration and validation of the system wavelength. The method can increase the number of calibration wavelengths and is suitable for both channels.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Spectral photon irradiance and spectral photon radiance standards for the calibration of photon-counting imagers
    Xiao, Yike
    Gan, Haiyong
    Liu, Xiangliang
    He, Yingwei
    Wang, Weimin
    Xu, Yinuo
    Jing, Xufeng
    Shen, Changyu
    QUANTUM INFORMATION TECHNOLOGY (AOPC 2019), 2019, 11339
  • [2] Wavelength calibration of absolute irradiance spectra-radiometer
    Liu, En-Chao
    Zheng, Xiao-Bing
    Li, Xin
    Zhang, Yan-Na
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2013, 21 (03): : 608 - 615
  • [3] Spectral irradiance comparison using a multi-wavelength filter radiometer
    Liu, Y. J.
    Xu, G.
    Ojanen, M.
    Ikonen, E.
    METROLOGIA, 2009, 46 (04) : S181 - S185
  • [4] Spectral irradiance measurement and actinic radiometer calibration for UV water disinfection
    Sperfeld, Peter
    Barton, Bettina
    Pape, Sven
    Towara, Anna-Lena
    Eggers, Jutta
    Hopfenmueller, Gabriel
    METROLOGIA, 2014, 51 (06) : S282 - S288
  • [5] Spectral irradiance calibration of space remote sensing spectral radiometer in range of UV and VUV
    Huang, Yu
    Wang, Shu-Rong
    Zhang, Zhen-Duo
    Lin, Guan-Yu
    Li, Fu-Tian
    Guangzi Xuebao/Acta Photonica Sinica, 2007, 36 (SUPPL.): : 187 - 191
  • [6] Solar ultraviolet spectral irradiance data with increased wavelength and irradiance accuracy
    VanHoosier, ME
    ULTRAVIOLET ATMOSPHERIC AND SPACE REMOTE SENSING: METHODS AND INSTRUMENTATION, 1996, 2831 : 57 - 64
  • [7] Coincidence Bins for Improving the Spectral Performance of Photon Counting Detectors
    Hsieh, S.
    MEDICAL PHYSICS, 2019, 46 (06) : E409 - E409
  • [8] Spectral calibration of photon-counting detectors at high photon flux
    Sidky, Emil Y.
    Paul, Emily R.
    Gilat-Schmidt, Taly
    Pan, Xiaochuan
    MEDICAL PHYSICS, 2022, 49 (10) : 6368 - 6383
  • [9] Correlation of spectral solar irradiance with solar activity as measured by VIRGO
    Wehrli, C.
    Schmutz, W.
    Shapiro, A. I.
    ASTRONOMY & ASTROPHYSICS, 2013, 556
  • [10] PERFORMANCE OF A MULTI-WAVELENGTH FILTER RADIOMETER FOR SPECTRAL IRRADIANCE MEASUREMENT IN THE NEAR IR
    Liu, Yuanjie
    Xu, Gan
    Huang, Xuebo
    Manoocheri, Farshid
    Ikonen, Erkki
    LIGHT & ENGINEERING, 2011, 19 (01): : 61 - 69