PERFORMANCE OF A MULTI-WAVELENGTH FILTER RADIOMETER FOR SPECTRAL IRRADIANCE MEASUREMENT IN THE NEAR IR

被引:0
|
作者
Liu, Yuanjie [1 ]
Xu, Gan [1 ]
Huang, Xuebo [1 ]
Manoocheri, Farshid
Ikonen, Erkki [2 ]
机构
[1] ASTAR, NMC, Opt Radiat Metrol Lab, Singapore, Singapore
[2] Aalto Univ, Metrol Res Inst, Alto, Finland
来源
LIGHT & ENGINEERING | 2011年 / 19卷 / 01期
基金
芬兰科学院;
关键词
InGaAs trap detector; multi-wavelength filter radiometer; MWFR; spectral irradiance; REALIZATION; SCALE; NM;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The performance of an automatic multi-wavelength filter radiometer (MWFR) in the near IR range is evaluated using a three-element InGaAs trap detector and nine narrow-band interference filters from NMC (Singapore) and MIKES (Finland) in a joint experiment conducted by researchers from both labs. Comparisons of detector spectral responsivity and filter spectral regular transmittance in the same wavelength range are also carried out. The maximum relative deviation of the measured photocurrent using MWFR and of the calculated photocurrent using known spectral irradiance values from a standard lamp is less than 1.8% with an expanded uncertainty of 1.9% (k = 2). From the promising results obtained from this and earlier work, it is concluded that a direct realisation of the spectral irradiance scale in the wavelength range of 300 run to 1600 nm is possible using the MWFR.
引用
收藏
页码:61 / 69
页数:9
相关论文
共 50 条
  • [1] Spectral irradiance comparison using a multi-wavelength filter radiometer
    Liu, Y. J.
    Xu, G.
    Ojanen, M.
    Ikonen, E.
    METROLOGIA, 2009, 46 (04) : S181 - S185
  • [2] APPLICATION OF InGaAs TRAP DETECTOR IN THE MULTI-WAVELENGTH FILTER RADIOMETER FOR SPECTRAL IRRADIANCE MEASUREMENT
    Liu, Y. J.
    Xu, G.
    Huang, X. B.
    Manoocheri, F.
    Ikonen, E.
    PROCEEDINGS OF THE CIE EXPERT SYMPOSIUM ON SPECTRAL AND IMAGING METHODS FOR PHOTOMETRY AND RADIOMETRY, 2010, : 94 - 98
  • [3] Characterization of spectral irradiance system based on a filter radiometer
    Lima, M. S.
    Silva, T. F.
    Duarte, I.
    Correa, J. S.
    Viana, D.
    Sousa, W. A.
    Almeida, G. B.
    Couceiro, I. B.
    8TH BRAZILIAN CONGRESS ON METROLOGY (METROLOGIA 2015), 2016, 733
  • [4] Multi-wavelength Solc birefringent filter
    Melich, Radek
    Melich, Zbynek
    Solc, Ivan
    ADVANCED OPTICAL AND MECHANICAL TECHNOLOGIES IN TELESCOPES AND INSTRUMENTATION, PTS 1-3, 2008, 7018
  • [5] A Multi-wavelength IR Laser for space applications
    Li, Steven X.
    Yu, Anthony W.
    Sun, Xiaoli
    Fahey, Molly E.
    Numata, Kenji
    Krainak, Michael A.
    LASER RADAR TECHNOLOGY AND APPLICATIONS XXII, 2017, 10191
  • [6] Calibration of the Irradiance Responsivity of a Filter Radiometer for T Measurement at NIM
    Lu, X.
    Yuan, Z.
    Hao, X.
    Lin, Y.
    Yang, J.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2011, 32 (1-2) : 278 - 284
  • [7] Calibration of the Irradiance Responsivity of a Filter Radiometer for T Measurement at NIM
    X. Lu
    Z. Yuan
    X. Hao
    Y. Lin
    J. Yang
    International Journal of Thermophysics, 2011, 32 : 278 - 284
  • [8] Switchable, tunable and highly stable multi-wavelength fiber laser based on a spectral filter
    Guzman-Chavez, A. D.
    Vargas-Rodriguez, E.
    Cano-Contreras, M.
    LASER PHYSICS, 2019, 29 (04)
  • [9] Comparison of filter radiometer spectral responsivity with the NIST spectral-irradiance and illuminance scales
    Tsai, BK
    Johnson, BC
    Saunders, RD
    Cromer, CL
    METROLOGIA, 1996, 32 (06) : 473 - 477
  • [10] Performance and application of a multi-wavelength, ground-based microwave radiometer in intense convective weather
    Chan, Pak Wai
    METEOROLOGISCHE ZEITSCHRIFT, 2009, 18 (03) : 253 - 265