Investigation of a multienzyme based amperometric biosensor for determination of sucrose in fruit juices

被引:0
|
作者
Krisztina Majer-Baranyi
Nóra Adányi
Mária Váradi
机构
[1] Central Food Research Institute,
来源
关键词
Amperometric biosensor; Sucrose; Thin layer cell; Glucose oxidase; Invertase; Mutarotase;
D O I
暂无
中图分类号
学科分类号
摘要
Determination of sucrose content is one of the most important routinely performed tests for quality control in the beverage industry. Thus, it is rather important to have a fast, simple and sensitive method that can be used for determination of sucrose in sweet-drink processing. The biosensor investigated was based on a thin layer enzyme cell in which glucose oxidase, invertase and mutarotase were immobilized on a protein membrane. Hydrogen peroxide as the product of the consecutive enzyme reaction was detected by amperometric technique. The optimum enzyme composition of invertase, mutarotase, and glucose oxidase for immobilisation was found to be 8498, 672, and 120 U using 2.2 mg BSA as protective agent dissolved in 200 μL phosphate buffer solution. To achieve the best measuring technique, changes in several parameters such as pH value, temperature and flow rate were studied. Having found the optimum conditions, the statistical parameters of the analysis were established. The linear range of the determination was between 1.0 × 10−4 and 2.5 × 10−3 mol/L with a correlation coefficient of 0.99. The sucrose content of several fruit juices was determined with this sensor, and the results were compared with an enzymatic reference method. The correlation between the two sucrose determination methods was found to be 0.97.
引用
收藏
页码:139 / 144
页数:5
相关论文
共 50 条
  • [31] HYBRID BIOSENSOR FOR THE DETERMINATION OF SUCROSE
    BARLIKOVA, A
    SVORC, J
    MIERTUS, S
    [J]. ANALYTICA CHIMICA ACTA, 1991, 247 (01) : 83 - 87
  • [32] Amperometric biosensors based on reduced GO and MWCNTs composite for polyphenols detection in fruit juices
    Vlamidis, Ylea
    Gualandi, Isacco
    Tonelli, Domenica
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 799 : 285 - 292
  • [33] An amperometric biosensor developed for detection of limonin levels in kinnow mandarin juices
    Raina Puri
    Meenakshi Malik
    Moushumi Ghosh
    [J]. Annals of Microbiology, 2012, 62 : 1301 - 1309
  • [34] An amperometric biosensor developed for detection of limonin levels in kinnow mandarin juices
    Puri, Raina
    Malik, Meenakshi
    Ghosh, Moushumi
    [J]. ANNALS OF MICROBIOLOGY, 2012, 62 (03) : 1301 - 1309
  • [35] AMPEROMETRIC DETERMINATION OF PHOSPHATE IONS BY BIOSENSOR
    KULYS, J
    HIGGINS, IJ
    BANNISTER, JV
    [J]. BIOSENSORS & BIOELECTRONICS, 1992, 7 (03): : 187 - 191
  • [36] AMPEROMETRIC BIOSENSOR FOR DETERMINATION OF ETHANOL VAPOR
    PARK, JK
    YEE, HJ
    KIM, ST
    [J]. BIOSENSORS & BIOELECTRONICS, 1995, 10 (6-7): : 587 - 594
  • [37] Amperometric biosensor for rapid determination of alanine
    Kwan, RCH
    Hon, PYT
    Renneberg, R
    [J]. ANALYTICA CHIMICA ACTA, 2004, 523 (01) : 81 - 88
  • [38] Performance of an amperometric biosensor for the determination of hemoglobin
    Jiang, LY
    Liu, CX
    Li, HQ
    Luo, XB
    Wu, YR
    Cai, XX
    [J]. JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2005, 5 (08) : 1301 - 1304
  • [39] AMPEROMETRIC BIOSENSOR FOR DETERMINATION OF LACTATE IN SWEAT
    FARIDNIA, MH
    PALLESCHI, G
    LUBRANO, GJ
    GUILBAULT, GG
    [J]. ANALYTICA CHIMICA ACTA, 1993, 278 (01) : 35 - 40
  • [40] A reagentless biosensor for the amperometric determination of NADH
    Cosnier, S
    Decout, JL
    Fontecave, M
    Frier, C
    Innocent, C
    [J]. ELECTROANALYSIS, 1998, 10 (08) : 521 - 525