Low-dose versus standard-dose normal temporal bone CT in children: a comparison study

被引:0
|
作者
Rashma, R. [1 ]
Kumar, Jyoti [1 ]
Garg, Anju [1 ]
Batra, Radhika [1 ]
Meher, Ravi [2 ]
Phulia, Ankita [1 ]
机构
[1] Lok Nayak Hosp, Maulana Azad Med Coll, Dept Radiodiag, Jawaharlal Nehru Marg, New Delhi 110002, India
[2] Maulana Azad Med Coll, Dept ENT & Head & Neck Surg, New Delhi, India
来源
关键词
Computed tomography; Temporal bone; Pediatric; Image noise; Image contrast; Radiation dosimetry; IMAGE QUALITY; CONTRAST; AGE;
D O I
10.1186/s43055-024-01254-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectiveTo compare the image quality of normal anatomical structures and radiation dose on low-dose (LDCT) and standard-dose (SDCT) temporal bone CT in children.MethodsThe study included 45 LDCT (80 kV and 130 mAs) and 45 SDCT (120 kV and 170 mAs) scans in children, 1-15 years of age. LDCT and SDCT scans were analyzed on H60s and H70h reconstruction kernels, respectively. Two readers assessed the image quality for 25 anatomical structures, using a 5-point scale. A score of 3 and above was considered "sufficient" and 2 and below was considered "insufficient" image quality. Image noise, contrast, age and size-specific effective doses were calculated.ResultsDespite an increase in image noise on LDCT, image quality remained sufficient for most structures owing to increased image contrast. The median effective dose on LDCT, calculated with age-specific conversion factor, decreased by 72.9% and that calculated with size-specific conversion factor decreased by 81.8% compared to the dose on SDCT.ConclusionLDCT provides comparable image quality for evaluation of temporal bone with significant reduction in radiation dose in children.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Comparison of low-dose and standard-dose total skin electron beam therapy in mycosis fungoides
    Dault, Joshua B.
    Slade, Alexander N.
    Zhao, Sherry
    Song, Shiyu
    [J]. LEUKEMIA & LYMPHOMA, 2019, 60 (09) : 2334 - 2336
  • [42] Comparison of Transplant Outcomes for Low-Dose and Standard-Dose Tacrolimus in Kidney Transplant Recipients.
    Cho, J. -H.
    Kim, K.
    Kim, M.
    Do, W.
    Yang, Y.
    Yim, T.
    Hwang, I.
    Lee, J. -H.
    Kwon, E.
    Jung, H. -Y.
    Choi, J. -Y.
    Park, S. -H.
    Kim, Y. -L.
    Kim, C. -D.
    [J]. AMERICAN JOURNAL OF TRANSPLANTATION, 2016, 16 : 541 - 541
  • [43] Comparison of Very Low-Dose Decitabine to Standard-Dose Hypomethylating Agents in Myelodysplastic Syndromes (MDS)
    Cheng, Connie
    Siebenaller, Caitlin
    Elson, Paul
    Advani, Anjali S.
    Carraway, Hetty E.
    Colaluca, Kristin
    Hamilton, Betty K.
    Hobson, Sean
    Kalaycio, Matt E.
    Maciejewski, Jaroslaw P.
    Mukherjee, Sudipto
    Rupp, Gin
    Zimmerman, Cassie
    Sekeres, Mikkael A.
    Gerds, Aaron T.
    [J]. BLOOD, 2014, 124 (21)
  • [44] Acute ischemic stroke: comparison of low-dose and standard-dose regimes of tissue plasminogen activator
    Sharma, Vijay K.
    Kawnayn, Ghulam
    Sarkar, Nabin
    [J]. EXPERT REVIEW OF NEUROTHERAPEUTICS, 2013, 13 (08) : 895 - 902
  • [45] EFFECTS OF LOW-DOSE OR STANDARD-DOSE ALTEPLASE ON THE OUTCOMES OF ENDOVASCULAR THROMBECTOMY
    Chen, C. -H.
    Hsieh, Y. -C.
    Tang, S. -C.
    Lien, L. -M.
    Chiou, H. -Y.
    Lee, J. -T.
    Jeng, J. -S.
    [J]. INTERNATIONAL JOURNAL OF STROKE, 2023, 18 (03) : 20 - 21
  • [46] Comparison of low-dose intradermal versus standard-dose intramuscular influenza vaccination in humans: Analysis of antibody and T cell responses
    Rychlik, Tami
    Kelly, Christy
    Morris, Mary
    Taylor, Bernadette
    [J]. JOURNAL OF IMMUNOLOGY, 2006, 176 : S128 - S128
  • [47] Comparison of Radiomic Models Based on Low-Dose and Standard-Dose CT for Prediction of Adenocarcinomas and Benign Lesions in Solid Pulmonary Nodules
    Liu, Jieke
    Xu, Hao
    Qing, Haomiao
    Li, Yong
    Yang, Xi
    He, Changjiu
    Ren, Jing
    Zhou, Peng
    [J]. FRONTIERS IN ONCOLOGY, 2021, 10
  • [48] Comparison of Setup Accuracy With Low-Dose Versus Standard-Dose CBCT in Pediatric and Adult Brain Image Guided Radiation Therapy
    Huynh-Le, M.
    Alcorn, S. R.
    Smith, K.
    McNutt, T. R.
    Hales, R. K.
    Kleinberg, L. R.
    Redmond, K. J.
    Terezakis, S. A.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S76 - S76
  • [49] EFFICACY AND SAFETY OF LOW-DOSE VERSUS STANDARD-DOSE ALTEPLASE REGIMENS IN PATIENTS WITH ACUTE ISCHAEMIC STROKE
    Skrbic, Ranko
    Vujkovic, Zoran
    Stojiljkovic, Milos P.
    Gajanin, Radoslav
    Bokonjic, Dubravko
    Komic, Jasmin
    [J]. PSYCHIATRIA DANUBINA, 2019, 31 : 32 - 38
  • [50] CT patterns of fungal pulmonary infections of the lung: Comparison of standard-dose and simulated low-dose CT (vol 81, pg 2860, 2012)
    Christe, Andreas
    Lin, Margaret C.
    Yen, Andrew C.
    Hallett, Rich L.
    Roychoudhury, Kingshuk
    Schmitzberger, Florian
    Fleischmann, Dominik
    Leung, Ann N.
    Rubin, Geoffrey D.
    Vock, Peter
    Roos, Justus E.
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (11) : 2067 - 2067