Low-dose versus standard-dose normal temporal bone CT in children: a comparison study

被引:0
|
作者
Rashma, R. [1 ]
Kumar, Jyoti [1 ]
Garg, Anju [1 ]
Batra, Radhika [1 ]
Meher, Ravi [2 ]
Phulia, Ankita [1 ]
机构
[1] Lok Nayak Hosp, Maulana Azad Med Coll, Dept Radiodiag, Jawaharlal Nehru Marg, New Delhi 110002, India
[2] Maulana Azad Med Coll, Dept ENT & Head & Neck Surg, New Delhi, India
来源
关键词
Computed tomography; Temporal bone; Pediatric; Image noise; Image contrast; Radiation dosimetry; IMAGE QUALITY; CONTRAST; AGE;
D O I
10.1186/s43055-024-01254-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectiveTo compare the image quality of normal anatomical structures and radiation dose on low-dose (LDCT) and standard-dose (SDCT) temporal bone CT in children.MethodsThe study included 45 LDCT (80 kV and 130 mAs) and 45 SDCT (120 kV and 170 mAs) scans in children, 1-15 years of age. LDCT and SDCT scans were analyzed on H60s and H70h reconstruction kernels, respectively. Two readers assessed the image quality for 25 anatomical structures, using a 5-point scale. A score of 3 and above was considered "sufficient" and 2 and below was considered "insufficient" image quality. Image noise, contrast, age and size-specific effective doses were calculated.ResultsDespite an increase in image noise on LDCT, image quality remained sufficient for most structures owing to increased image contrast. The median effective dose on LDCT, calculated with age-specific conversion factor, decreased by 72.9% and that calculated with size-specific conversion factor decreased by 81.8% compared to the dose on SDCT.ConclusionLDCT provides comparable image quality for evaluation of temporal bone with significant reduction in radiation dose in children.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Computed tomography evaluation of the normal appendix: Comparison of low-dose and standard-dose unenhanced helical computed tomography
    Karabulut, Nevzat
    Boyaci, Nurefsan
    Yagci, Baki
    Herek, Duygu
    Kiroglu, Yimaz
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2007, 31 (05) : 732 - 740
  • [22] Multi-detector row CT pulmonary angiography: Comparison of standard-dose and simulated low-dose techniques
    Tack, D
    De Maertelaer, V
    Petit, W
    Scillia, P
    Muller, P
    Suess, C
    Gevenois, PA
    [J]. RADIOLOGY, 2005, 236 (01) : 318 - 325
  • [23] More on Low-Dose versus Standard-Dose Intravenous Alteplase in Acute Ischemic Stroke
    Anderson, Craig S.
    Woodward, Mark
    Chalmers, John
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2018, 378 (15): : 1465 - 1466
  • [24] A randomized, crossover comparison of standard-dose versus low-dose lenograstim in the prophylaxis of post-chemotherapy neutropenia
    Juan, O
    Campos, JM
    Carañana, V
    Sanchez, JJ
    Casañ, R
    Alberola, V
    [J]. SUPPORTIVE CARE IN CANCER, 2001, 9 (04) : 241 - 246
  • [25] A randomized, crossover comparison of standard-dose versus low-dose lenograstim in the prophylaxis of post-chemotherapy neutropenia
    Oscar Juan
    Juan Campos
    Vicente Carañana
    Jose Sanchez
    Rosa Casañ
    Vicente Alberola
    [J]. Supportive Care in Cancer, 2001, 9 : 241 - 246
  • [26] Comparison of low-dose deferoxamine versus standard-dose deferoxamine for treatment of aluminium overload among haemodialysis patients
    Kan, Wei-Chih
    Chien, Chih-Chiang
    Wu, Chia-Chun
    Su, Shih-Bin
    Hwang, Jyh-Chang
    Wang, Hsien-Yi
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2010, 25 (05) : 1604 - 1608
  • [27] Low-Dose Temporal Bone CT in Infants and Young Children: Effective Dose and Image Quality
    Nauer, C. B.
    Rieke, A.
    Zubler, C.
    Candreia, C.
    Arnold, A.
    Senn, P.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (08) : 1375 - 1380
  • [28] Low-dose versus standard-dose rtPA in acute ischemic stroke - an explorative single-center study
    Schwarz, G.
    Vabanesi, M.
    Strambo, D.
    Comi, G.
    Roveri, L.
    [J]. CEREBROVASCULAR DISEASES, 2017, 43
  • [29] Multidetector CT in patients suspected of having lumbar disk herniation: Comparison of standard-dose and simulated low-dose techniques
    Bohy, Pascale
    de Maertelaer, Viviane
    Roquigny, Aymeric
    Keyzer, Caroline
    Tack, Denis
    Gevenois, Pierre Alain
    [J]. RADIOLOGY, 2007, 244 (02) : 524 - 531
  • [30] Low-dose versus standard-dose rtPA in acute ischemic stroke: An explorative single-centre study
    Vabanesi, M.
    Schwarz, G.
    Strambo, D.
    Comi, G.
    Roveri, L.
    [J]. EUROPEAN JOURNAL OF NEUROLOGY, 2017, 24 : 364 - 365