Low-dose versus standard-dose normal temporal bone CT in children: a comparison study

被引:0
|
作者
Rashma, R. [1 ]
Kumar, Jyoti [1 ]
Garg, Anju [1 ]
Batra, Radhika [1 ]
Meher, Ravi [2 ]
Phulia, Ankita [1 ]
机构
[1] Lok Nayak Hosp, Maulana Azad Med Coll, Dept Radiodiag, Jawaharlal Nehru Marg, New Delhi 110002, India
[2] Maulana Azad Med Coll, Dept ENT & Head & Neck Surg, New Delhi, India
来源
关键词
Computed tomography; Temporal bone; Pediatric; Image noise; Image contrast; Radiation dosimetry; IMAGE QUALITY; CONTRAST; AGE;
D O I
10.1186/s43055-024-01254-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
ObjectiveTo compare the image quality of normal anatomical structures and radiation dose on low-dose (LDCT) and standard-dose (SDCT) temporal bone CT in children.MethodsThe study included 45 LDCT (80 kV and 130 mAs) and 45 SDCT (120 kV and 170 mAs) scans in children, 1-15 years of age. LDCT and SDCT scans were analyzed on H60s and H70h reconstruction kernels, respectively. Two readers assessed the image quality for 25 anatomical structures, using a 5-point scale. A score of 3 and above was considered "sufficient" and 2 and below was considered "insufficient" image quality. Image noise, contrast, age and size-specific effective doses were calculated.ResultsDespite an increase in image noise on LDCT, image quality remained sufficient for most structures owing to increased image contrast. The median effective dose on LDCT, calculated with age-specific conversion factor, decreased by 72.9% and that calculated with size-specific conversion factor decreased by 81.8% compared to the dose on SDCT.ConclusionLDCT provides comparable image quality for evaluation of temporal bone with significant reduction in radiation dose in children.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Comparison of low-dose with standard-dose multidetector CT in cervical spine trauma
    Mulkens, T. H.
    Marchal, P.
    Daineffe, S.
    Salgado, R.
    Bellinck, P.
    te Rijdt, B.
    Kegelaers, B.
    Termote, J-L
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2007, 28 (08) : 1444 - 1450
  • [2] Comparison of low-dose and standard-dose helical CT in the evaluation of pulmonary nodules
    Nevzat Karabulut
    Mustafa Törü
    Veli Gelebek
    Meltem Gülsün
    Macit O. Ariyürek
    [J]. European Radiology, 2002, 12 : 2764 - 2769
  • [3] Comparison of low-dose and standard-dose helical CT in the evaluation of pulmonary nodules
    Karabulut, N
    Törü, M
    Gelebek, V
    Gülsün, M
    Ariyurek, OM
    [J]. EUROPEAN RADIOLOGY, 2002, 12 (11) : 2764 - 2769
  • [4] Low-dose versus standard-dose azithromycin for treatment of yaws
    Mikalova, Lenka
    Smajs, David
    [J]. LANCET GLOBAL HEALTH, 2018, 6 (04): : E357 - E358
  • [5] CT patterns of fungal pulmonary infections of the lung: Comparison of standard-dose and simulated low-dose CT
    Christe, Andreas
    Lin, Margaret C.
    Yen, Andrew C.
    Hallett, Rich L.
    Roychoudhury, Kingshuk
    Schmitzberger, Florian
    Fleischmann, Dominik
    Leung, Ann N.
    Rubin, Geoffry D.
    Vock, Peter
    Roos, Justus E.
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (10) : 2860 - 2866
  • [6] Low-dose versus standard-dose CT protocol in patients with clinically suspected renal colic
    Poletti, Pierre-Alexandre
    Platon, Alexandra
    Rutschmann, Olivier T.
    Schmidlin, Franz R.
    Iselin, Christophe E.
    Becker, Christoph D.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (04) : 927 - 933
  • [7] Comparison between low-dose and standard-dose multidetector CT in patients with suspected chronic sinusitis
    Tack, D
    Widelec, J
    De Maertelaer, V
    Bailly, JM
    Delcour, C
    Gevenois, PA
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (04) : 939 - 944
  • [8] Low-dose versus standard-dose lenograstim prophylaxis after chemotherapy: A randomized, crossover comparison
    Toner, GC
    Shapiro, JD
    Laidlaw, CR
    Rischin, D
    Millward, MJ
    Wolf, M
    Januszewicz, H
    Mitchell, SV
    Curran, AC
    Matthews, JP
    Bishop, JF
    [J]. JOURNAL OF CLINICAL ONCOLOGY, 1998, 16 (12) : 3874 - 3879
  • [9] Comparison of low-dose and standard-dose multirow detector helical CT of the sinuses and computer simulation of effective dose
    Tack, DM
    Widelec, J
    Bailly, J
    Delcour, CP
    [J]. RADIOLOGY, 2001, 221 : 620 - 620
  • [10] A detection system for low-dose and standard-dose CT-colonography (CTC)
    Agliozzo, S.
    Baggio, R.
    Bert, A.
    Boda, P.
    Campanella, D.
    Dmitriev, I.
    Regge, D.
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2007, 2 : S378 - S380