Actinide molecular ion formation in collision/reaction cell of triple quadrupole ICP-MS/MS and its application to quantitative actinide analysis

被引:0
|
作者
T. Suzuki
T. Yamamura
C. Abe
K. Konashi
Y. Shikamori
机构
[1] Nagaoka University of Technology,Department of Nuclear System Safety Engineering
[2] Institute for Materials Research,Laboratory of Alpha
[3] Tohoku University,Ray Emitters
[4] Kyoto University,Institute for Integrated Radiation and Nuclear Science
[5] Tohoku University,Institute for Materials Research
[6] Agilent Technologies Japan,undefined
[7] Ltd.,undefined
关键词
Uranium; Neptunium; Plutonium; Americium; Curium; Oxygen reaction;
D O I
暂无
中图分类号
学科分类号
摘要
A study for the quantitative actinide analysis by using a triple quadrupole ICP-MS/MS, Agilent 8900, was carried out. We confirmed the formation percentages of ionic species of each actinide in several kinds of collision/reaction cell modes. It was found that the dominant ions in oxygen gas mode were oxide ions, and the ratio of monoxide ion/dioxide ion increases with atomic number in the case of same oxygen gas flow rate. The percentages of actinide ion and oxide ions depend on the oxygen gas flow rate, and the number of oxygen attached on actinides increases with the oxygen gas flow rate.
引用
收藏
页码:221 / 225
页数:4
相关论文
共 50 条
  • [21] Determination of 90Sr in large mass of apples and cabbages by triple quadruple collision/reaction cell ICP-MS
    Zhong, Ningjie
    Zhao, Xinghong
    Li, Lili
    Xu, Changkun
    Huang, Shenghui
    Zhao, Lifei
    Zhao, Yonggang
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2025, 334 (01) : 131 - 140
  • [22] The use of collision/reaction cell ICP-MS for the determination of elements in blood and serum samples
    Wahlen, R
    Evans, L
    Turner, J
    Hearn, R
    SPECTROSCOPY, 2005, 20 (12) : 84 - 89
  • [23] Determination of 21 elements in human serum using ICP-MS with collision/reaction cell
    Gong, Zi-Shan
    Jiang, Xue-Hui
    Sun, Chuan-Qiang
    Tian, Ya-Ping
    Guo, Guang-Hong
    Zhang, Yang-Zan
    Zhao, Xue-Hong
    Wang, Yan
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2017, 423 : 20 - 26
  • [24] Application of a hexapole collision and reaction cell in ICP-MS Part II: Analytical figures of merit and first applications
    I. Feldmann
    N. Jakubowski
    C. Thomas
    D. Stuewer
    Fresenius' Journal of Analytical Chemistry, 1999, 365 : 422 - 428
  • [25] Application of ICP-MS with a hexapole collision and reaction cell as an element selective phosphorus detector for quality control of pharmaceuticals
    Edler, Michael
    Busker, Eberhard
    Feldmann, Ingo
    Jakubowski, Norbert
    Venzag, Cornel
    Plasma Source Mass Spectrometry: Current Trends and Future Developments, 2005, (301): : 99 - 110
  • [26] Application of a hexapole collision and reaction cell in ICP-MS Part II: Analytical figures of merit and first applications
    Feldmann, I
    Jakubowski, N
    Thomas, C
    Stuewer, D
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 365 (05): : 422 - 428
  • [27] Determination of ultratrace 129I in soil samples by Triple Quadrupole ICP-MS and its application to Fukushima soil samples
    Ohno, Takeshi
    Muramatsu, Yasuyuki
    Shikamori, Yasuyuki
    Toyama, Chiaki
    Okabe, Nobuaki
    Matsuzaki, Hiroyuki
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2013, 28 (08) : 1283 - 1287
  • [28] Polyatomic interference removal using a collision reaction interface for plutonium determination in the femtogram range by quadrupole ICP-MS
    Olufson, Kylie P.
    Moran, Grainne
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2016, 308 (02) : 639 - 647
  • [29] Polyatomic interference removal using a collision reaction interface for plutonium determination in the femtogram range by quadrupole ICP-MS
    Kylie P. Olufson
    Grainne Moran
    Journal of Radioanalytical and Nuclear Chemistry, 2016, 308 : 639 - 647
  • [30] Coupling between a calix[6]arene-based chromatography column and ICP-MS for on-line actinide analysis
    Baghdadi, S.
    Cote, G.
    Beyaert, C.
    Mane, B.
    Peroux, A.
    Masclet, L.
    Rebiere, F.
    Agarande, M.
    Bouvier-Capely, C.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (07) : 1406 - 1413