A study on contralateral breast surface dose for various tangential field techniques and the impact of set-up error on this dose

被引:0
|
作者
R. Prabhakar
K. P. Haresh
P. K. Julka
T. Ganesh
G. K. Rath
R. C. Joshi
M. Sasindran
K. K. Naik
P. S. Sridhar
机构
[1] All India Institute of Medical Sciences,Department of Radiotherapy, Institute Rotary Cancer Hospital
[2] New Delhi,undefined
关键词
contralateral breast dose; MOSFET; enhanced dynamic wedge; IMRT;
D O I
暂无
中图分类号
学科分类号
摘要
The risk of inducing contralateral breast (CLB) cancer in patients undergoing tangential field irradiation for the treatment of breast cancer is a serious concern in radiation oncology. A bilateral breast phantom made of wax attached onto the Alderson Rando phantom was used for studying the CLB dose for techniques using physical wedges, EDWs, IMRT and open fields. The skin dose to the CLB was measured at four different points (3 cm from the medial border of the tangential field (P1), nipple (P3), axilla (P4), midpoint between P3 and P1 (P2)). The highest measured dose occurred at P1 with the 60° physical wedges; it was 15.3 % of the dose at isocentre. Similarly, the dose measured at P3 (nipple) with 60° physical wedges was 1.90 times higher than the dose with 60° EDWs. The dose at P1 for IMRT (7.8%) was almost the same as that for the open field (8.7%). The skin dose measured at the nipple was 2.1 – 10.9 % of the isocentre dose. The highest CLB doses were contributed by medial wedged fields. The dose to the CLB can be reduced by using IMRT or avoiding wedging the medial tangential fields. A set-up error in the longitudinal direction has little impact on the CLB dose. Set-up errors >1 cm in the vertical and lateral directions have significant impact on the CLB dose.
引用
收藏
页码:42 / 45
页数:3
相关论文
共 43 条
  • [21] Thyroid and contralateral breast surface dose variation in mammography: a phantom study on the role of breast tissue composition
    Ekinci, Fatih
    Aslar, Engin
    EUROPEAN PHYSICAL JOURNAL PLUS, 2024, 139 (04):
  • [22] IMPACT OF DIFFERENT BREATHING CONDITIONS ON THE DOSE TO SURROUNDING NORMAL STRUCTURES IN TANGENTIAL FIELD BREAST RADIOTHERAPY.
    Prabhakar, R.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S136 - S136
  • [23] The dosimetric impact of respiratory breast movement and daily setup error on tangential whole breast irradiation using conventional wedge, field-in-field and irregular surface compensator techniques
    Furuya, Tomohisa
    Sugimoto, Satoru
    Kurokawa, Chie
    Ozawa, Shuichi
    Karasawa, Kumiko
    Sasai, Keisuke
    JOURNAL OF RADIATION RESEARCH, 2013, 54 (01) : 157 - 165
  • [24] The Impact of Set-up Errors on Normal Tissue Doses and the Perceived Dose/Volume Response for Patients Receiving Tangents for Left-Sided Breast Cancer
    Yoon, W. S.
    Marks, L. B.
    Das, S. K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : E62 - E63
  • [25] An innovative digital imaging set-up allowing a low-dose approach to phase contrast applications in the medical field
    Olivo, A
    Arfelli, F
    Cantatore, G
    Longo, R
    Menk, RH
    Pani, S
    Prest, M
    Poropat, P
    Rigon, L
    Tromba, G
    Vallazza, E
    Castelli, E
    MEDICAL PHYSICS, 2001, 28 (08) : 1610 - 1619
  • [26] The effect of systematic set-up deviations on the absorbed dose distribution for left-sided breast cancer treated with respiratory gating
    Edvardsson, A.
    Ceberg, S.
    7TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2013, 444
  • [27] Impact of surface-guided positioning on the use of portal imaging and initial set-up duration in breast cancer patients
    Pazos, Montserrat
    Walter, Franziska
    Reitz, Daniel
    Schoenecker, Stephan
    Konnerth, Dinah
    Schaefer, Annemarie
    Rottler, Maya
    Alongi, Filippo
    Freislederer, Philipp
    Niyazi, Maximilian
    Belka, Claus
    Corradini, Stefanie
    STRAHLENTHERAPIE UND ONKOLOGIE, 2019, 195 (11) : 964 - 971
  • [28] Skin Surface Dose for Whole Breast Radiotherapy Using Personalized Breast Holder: Comparison with Various Radiotherapy Techniques and Clinical Experiences
    Chen, Chiu-Ping
    Lin, Chi-Yeh
    Kuo, Chia-Chun
    Chen, Tung-Ho
    Lin, Shao-Chen
    Tseng, Kuo-Hsiung
    Cheng, Hao-Wen
    Chao, Hsing-Lung
    Yen, Sang-Hue
    Lin, Ruo-Yu
    Feng, Chen-Ju
    Lu, Long-Sheng
    Chiou, Jeng-Fong
    Hsu, Shih-Ming
    CANCERS, 2022, 14 (13)
  • [29] Evaluation of the detection accuracy of set-up for various treatment sites using surface-guided radiotherapy system, VOXELAN: a phantom study
    Saito, Masahide
    Ueda, Koji
    Suzuki, Hidekazu
    Komiyama, Takafumi
    Marino, Kan
    Aoki, Shinichi
    Sano, Naoki
    Onishi, Hiroshi
    JOURNAL OF RADIATION RESEARCH, 2022, 63 (03) : 435 - 442
  • [30] A RANDOMISED STUDY ON SET-UP ERROR IN BREAST CANCER RADIOTHERAPY BY EPID WITH DIFFERENT METHODS. PRELIMINARY CLINICAL EXPERIENCE WITH VISION RT.
    Ferrara, T.
    Zucca, S.
    Ciccotto, M. G.
    Schirra, V.
    Solla, I.
    Ferrara, C.
    Madeddu, A.
    Murtas, R.
    Deidda, M. A.
    Meleddu, G.
    Gabriele, P.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S522 - S523