A study on contralateral breast surface dose for various tangential field techniques and the impact of set-up error on this dose

被引:0
|
作者
R. Prabhakar
K. P. Haresh
P. K. Julka
T. Ganesh
G. K. Rath
R. C. Joshi
M. Sasindran
K. K. Naik
P. S. Sridhar
机构
[1] All India Institute of Medical Sciences,Department of Radiotherapy, Institute Rotary Cancer Hospital
[2] New Delhi,undefined
关键词
contralateral breast dose; MOSFET; enhanced dynamic wedge; IMRT;
D O I
暂无
中图分类号
学科分类号
摘要
The risk of inducing contralateral breast (CLB) cancer in patients undergoing tangential field irradiation for the treatment of breast cancer is a serious concern in radiation oncology. A bilateral breast phantom made of wax attached onto the Alderson Rando phantom was used for studying the CLB dose for techniques using physical wedges, EDWs, IMRT and open fields. The skin dose to the CLB was measured at four different points (3 cm from the medial border of the tangential field (P1), nipple (P3), axilla (P4), midpoint between P3 and P1 (P2)). The highest measured dose occurred at P1 with the 60° physical wedges; it was 15.3 % of the dose at isocentre. Similarly, the dose measured at P3 (nipple) with 60° physical wedges was 1.90 times higher than the dose with 60° EDWs. The dose at P1 for IMRT (7.8%) was almost the same as that for the open field (8.7%). The skin dose measured at the nipple was 2.1 – 10.9 % of the isocentre dose. The highest CLB doses were contributed by medial wedged fields. The dose to the CLB can be reduced by using IMRT or avoiding wedging the medial tangential fields. A set-up error in the longitudinal direction has little impact on the CLB dose. Set-up errors >1 cm in the vertical and lateral directions have significant impact on the CLB dose.
引用
收藏
页码:42 / 45
页数:3
相关论文
共 43 条
  • [11] Evaluation of the dose within the abutment region between tangential and supraclavicular fields for various breast irradiation techniques
    Homann, K
    Gates, B
    Salehpour, M
    Followill, D
    Kirsner, S
    Buchholz, T
    White, R
    Prado, K
    MEDICAL PHYSICS, 2005, 32 (06) : 1995 - 1995
  • [12] THE IMPACT OF ROTATIONAL SET-UP ERRORS ON THE DOSE DISTRIBUTION GIVEN TO H&N PATIENTS
    Logadottir, A.
    Smulders, B.
    Bangsgaard, J. P.
    Bjork-Eriksson, T.
    Kristensen, C. A.
    Specht, L.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S532 - S532
  • [13] Effects of Setup Errors on Dose Distribution for Tangential Wedge Field and Field-in-Field Techniques During Breast Irradiation
    Sonmez, Aydan
    Onal, Cem
    Sonmez, Serhat
    Arslan, Gungor
    Parlak, Cem
    Topkan, Erkan
    Yavuz, Melek
    UHOD-ULUSLARARASI HEMATOLOJI-ONKOLOJI DERGISI, 2014, 24 (02): : 130 - 138
  • [14] EFFECT OF SET-UP ERROR ON THE DOSE ACROSS THE JUNCTION OF MATCHING CRANIAL-SPINAL FIELDS IN THE TREATMENT OF MEDULLOBLASTOMA
    HOLUPKA, EJ
    HUMM, JL
    TARBELL, NJ
    SVENSSON, GK
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 (02): : 345 - 352
  • [15] A fluence-convolution method to calculate radiation therapy dose distributions that incorporate random set-up error
    Beckham, WA
    Keall, PJ
    Siebers, JV
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (19): : 3465 - 3473
  • [16] THE EFFECT OF SET-UP ERROR ON DELIVERED DOSE IN CURATIVE RADIOTHERAPY FOR NON-SMALL CELL LUNG CANCER
    Xing, Aitang
    Holloway, Lois
    Kumar, Shivani
    Ochoa, Cesar
    Vinod, Shalini K.
    JOURNAL OF THORACIC ONCOLOGY, 2011, 6 (06) : S803 - S804
  • [17] Impact of different breathing conditions on the dose to surrounding normal structures in tangential field breast radiotherapy
    Prabhakar, Ramachandran
    Tharmar, Ganesh
    Julka, Pramod K.
    Rath, Goura K.
    Joshi, Rakesh C.
    Bansal, Anil K.
    Bisht, R. K.
    Gopishankar, N.
    Pant, G. S.
    Thulkar, S.
    JOURNAL OF MEDICAL PHYSICS, 2007, 32 (01) : 24 - 28
  • [18] A new device of real time dose monitoring system for preventing the set-up error with using flat panel detectors (FDP) in patient with breast cancer
    Kamikonya, N.
    Takada, Y.
    Fujiwara, M.
    Tsuboi, K.
    Nakao, N.
    Nakagawa, H.
    Tanooka, M.
    Yamamoto, E.
    Inoue, H.
    Yasumasa, K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S628 - S629
  • [19] Evaluation of different set-up error corrections on dose-volume metrics in prostate IMRT using CBCT images
    Hirose, Yoshinori
    Nakamura, Mitsuhiro
    Tomita, Tsuneyuki
    Kitsuda, Kenji
    Notogawa, Takuya
    Miki, Katsuhito
    Nakamura, Kiyonao
    Ishigaki, Takashi
    JOURNAL OF RADIATION RESEARCH, 2014, 55 (05) : 966 - 975
  • [20] Dosimetric Impact of Patients Set-Up Effect in Radiation Therapy Planning System for Breast Cancer Patients with Conventional Wedge and Field-In-Field Techniques
    Lee, S.
    Suh, T.
    Kim, J.
    Park, J.
    Kim, D.
    MEDICAL PHYSICS, 2013, 40 (06)