Comparison of styrene removal in air by positive and negative DC corona discharges

被引:0
|
作者
X. Zhang
W. Feng
Z. Yu
S. Li
J. Zhu
K. Yan
机构
[1] Zhejiang University,Department of Chemical and Biological Engineering, Key Laboratory of Biomass Chemical Engineering of Ministry of Education
关键词
Corona discharge; Non-thermal plasma; Styrene; VOCs;
D O I
暂无
中图分类号
学科分类号
摘要
This communication discusses styrene removal in air by positive and negative DC corona discharges. Experiments were performed with a wire-plate reactor and under a gas flow rate of 305 m3/h. In terms of averaged applied voltage and corona current, it is observed that the maximum negative corona current is always at least two times larger than the positive one at the same voltage level. At the same corona discharge energy density, however, the positive corona discharge produces around 2–6 times more ozone in comparison with the negative corona. For styrene removal, the positive corona processing is also around 2–6 times more effective than the negative corona. Humidity, an important and variable component of ambient air, affects the positive corona processing significantly. But it exerts a moderate effect on the negative corona. The differences between positive corona and negative corona discharges are attributed to their different discharge properties.
引用
收藏
页码:1377 / 1382
页数:5
相关论文
共 50 条
  • [41] Comparative Study of AC and Positive and Negative DC Visual Corona for Sphere-Plane Gaps in Atmospheric Air
    Riba, Jordi-Roger
    Morosini, Andrea
    Capelli, Francesca
    [J]. ENERGIES, 2018, 11 (10)
  • [42] Electric wind characterisation in negative point-to-plane corona discharges in air
    Béquin, P
    Castor, K
    Scholten, J
    [J]. EUROPEAN PHYSICAL JOURNAL-APPLIED PHYSICS, 2003, 22 (01): : 41 - 49
  • [43] Negative corona, glow and spark discharges in ambient air and transitions between them
    Akishev, Y
    Grushin, M
    Kochetov, I
    Karal'nik, V
    Napartovich, A
    Trushkin, N
    [J]. PLASMA SOURCES SCIENCE & TECHNOLOGY, 2005, 14 (02): : S18 - S25
  • [44] Electrical Analysis of Pulsed Positive Multipoint Corona Discharges in Air at Atmospheric Pressure
    Abahazem, A.
    Mraihi, A.
    Merbahi, N.
    Yousfi, M.
    Eichwald, O.
    [J]. IEEE TRANSACTIONS ON PLASMA SCIENCE, 2011, 39 (11) : 2230 - 2231
  • [45] Theory of stability of self-sustaining dc discharges at inception with application to negative corona
    Almeida, P.G.C.
    Naidis, G.V.
    Benilov, M.S.
    [J]. Physical Review E, 2024, 110 (04)
  • [46] LOCALIZED CORONA DISCHARGES AT A NEGATIVE ELECTRODE
    LOOMS, JST
    [J]. NATURE, 1955, 176 (4490) : 977 - 978
  • [47] Vapor polymerization of styrene in air by combined treatment in direct-current and pulsed corona discharges
    Shvedchikov, AP
    Belousova, EV
    Ponizovskii, AZ
    Ponizovskii, LZ
    [J]. HIGH ENERGY CHEMISTRY, 1999, 33 (01) : 35 - 39
  • [48] Current-voltage characteristics of dc corona discharges in air between coaxial cylinders
    Zheng, Yuesheng
    Zhang, Bo
    He, Jinliang
    [J]. PHYSICS OF PLASMAS, 2015, 22 (02)
  • [49] Influence of Air Pressure on Positive DC Corona Inception Voltage of Stranded Conductors in the Corona cage
    Meng, Xiaobo
    Bian, Xingming
    Chen, Fenglin
    Yang, Yingjian
    Wang, Liming
    Guan, Zhicheng
    [J]. 2010 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTIC PHENOMENA, 2010,
  • [50] POSITIVE DC CORONA AND SPARK CHARACTERISTICS IN HIGH-PRESSURE AIR
    TAKUMA, T
    CHIBA, M
    [J]. ELECTRICAL ENGINEERING IN JAPAN, 1968, 88 (09) : 10 - &