Comparison of styrene removal in air by positive and negative DC corona discharges

被引:0
|
作者
X. Zhang
W. Feng
Z. Yu
S. Li
J. Zhu
K. Yan
机构
[1] Zhejiang University,Department of Chemical and Biological Engineering, Key Laboratory of Biomass Chemical Engineering of Ministry of Education
关键词
Corona discharge; Non-thermal plasma; Styrene; VOCs;
D O I
暂无
中图分类号
学科分类号
摘要
This communication discusses styrene removal in air by positive and negative DC corona discharges. Experiments were performed with a wire-plate reactor and under a gas flow rate of 305 m3/h. In terms of averaged applied voltage and corona current, it is observed that the maximum negative corona current is always at least two times larger than the positive one at the same voltage level. At the same corona discharge energy density, however, the positive corona discharge produces around 2–6 times more ozone in comparison with the negative corona. For styrene removal, the positive corona processing is also around 2–6 times more effective than the negative corona. Humidity, an important and variable component of ambient air, affects the positive corona processing significantly. But it exerts a moderate effect on the negative corona. The differences between positive corona and negative corona discharges are attributed to their different discharge properties.
引用
收藏
页码:1377 / 1382
页数:5
相关论文
共 50 条
  • [31] Study of the Development of Negative DC Corona Discharges on the Basis of Visible Digital Images
    Guo, Ziqing
    Ye, Qizheng
    Wang, Yuwei
    Han, Mengting
    [J]. IEEE TRANSACTIONS ON PLASMA SCIENCE, 2020, 48 (07) : 2509 - 2514
  • [32] Removal of NOx by DC and pulsed corona discharges in a wet electrostatic precipitator model
    Dors, M
    Mizeraczyk, J
    Czech, T
    Rea, M
    [J]. JOURNAL OF ELECTROSTATICS, 1998, 45 (01) : 25 - 36
  • [33] On the different regimes of positive DC corona discharges as a function of electrical and geometrical parameters
    Yan, Huijie
    Benard, Nicolas
    Moreau, Eric
    [J]. JOURNAL OF APPLIED PHYSICS, 2023, 133 (01)
  • [34] Numerical Simulations of Ionic Wind Induced by Positive DC-Corona Discharges
    Picella, Francesco
    Fabre, David
    Plouraboue, Franck
    [J]. AIAA JOURNAL, 2024, 62 (07) : 2562 - 2573
  • [35] Progress in the visualization of filamentary gas discharges. Part 2: Visualization of DC positive corona discharges
    Mizeraczyk, J
    Kanazawa, S
    Ohkubo, T
    [J]. JOURNAL OF ADVANCED OXIDATION TECHNOLOGIES, 2004, 7 (01) : 20 - 30
  • [36] Effects of Cross Section Geometry on the Positive Corona Discharges in the DC Transmission Conductors
    Zhang, Xinchun
    Cao, Yingping
    Wang, Zengji
    Wang, Feng
    [J]. Gaodianya Jishu/High Voltage Engineering, 2020, 46 (07): : 2487 - 2495
  • [37] GROWTH OF CORONA DISCHARGES IN AIR
    TAMURA, T
    [J]. JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 1961, 16 (12) : 2503 - &
  • [38] MODES OF CORONA DISCHARGES IN AIR
    GIAO, TN
    JORDAN, JB
    [J]. IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1968, PA87 (05): : 1207 - &
  • [39] VARIATION WITH TIME OF PULSES IN AIR AT MODERATE PRESSURES IN ELECTRODELESS DC CORONA DISCHARGES
    PIMPALE, SG
    [J]. INDIAN JOURNAL OF PHYSICS AND PROCEEDINGS OF THE INDIAN ASSOCIATION FOR THE CULTIVATION OF SCIENCE, 1973, 47 (12): : 751 - 754
  • [40] COMPARATIVE INVESTIGATIONS ON MAGNETICAL ENHANCED NEGATIVE- AND POSITIVE-CORONA DISCHARGES
    Mi, Junfeng
    Xu, Dexuan
    Tian, Ximei
    Sun, Yinghao
    Zhang, Xiaoyu
    [J]. INTERNATIONAL JOURNAL OF MODERN PHYSICS B, 2009, 23 (26): : 5131 - 5142