Validation of the use of foreign gas rebreathing method for non-invasive determination of cardiac output in heart disease patients.

被引:28
|
作者
Dong L. [1 ]
Wang J.A. [1 ]
Jiang C.Y. [1 ]
机构
[1] Department of Cardiology, Sir Run Run Shaw Hospital, School of Medicine, Zhejiang University, Hangzhou
来源
关键词
Indirect Fick (foreign gas rebreathing); Swan-Ganz; Cardiac output; Left ventricle radiography; Echocardiography; R543.3;
D O I
10.1631/jzus.2005.B1157
中图分类号
学科分类号
摘要
OBJECTIVE: To compare a new device (Innocor) for non-invasive measurement of cardiac output (CO) by foreign gas rebreathing method with conventional techniques used in the measurements of cardiac function. METHODS: Cardiac outputs measured by Innocor (CO(RB)) were compared with CO obtained by echocardiography (CO(EC)), Swan-Ganz thermodilution (CO(TD)), and left ventricle radiography (CO(LVR)) in 34 patients subjected to cardiac catheterization. Values obtained from the four methods were analyzed by linear regression and paired values were compared by the method of Bland and Altman in SPSS. RESULTS: There was strong positive correlation (r=0.94) between Innocor cardiac output values and the corresponding values obtained by thermodilution and between CO(EC) and CO(LVR) values. Thermodilution appears to overestimate cardiac output when compared to the values obtained with Innocor by (0.66+/-0.22) L/min (P<0.0001). There was no correlation between data obtained by Innocor and the corresponding CO(EC) and CO(LVR) values. CONCLUSION: Innocor CO(RB) is an easy, safe and well established method for non-invasive measurement of cardiac output with good prospects for clinical application in heart disease patients.
引用
收藏
页码:1157 / 1162
页数:5
相关论文
共 50 条
  • [31] Non-Invasive Cardiac Output Measurement Using Inert Gas Rebreathing Method during Cardiopulmonary Exercise Testing-A Systematic Review
    Chwiedz, Agnieszka
    Minarowski, Lukasz
    Mroz, Robert M.
    Hady, Hady Razak
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (22)
  • [32] Novel non-invasive technology for cardiac output determination
    U Borg
    D Iyer
    Q Huang
    Y Li
    C Baker
    Critical Care, 18 (Suppl 1):
  • [33] EVALUATION OF THE CO2 REBREATHING METHOD FOR THE NON-INVASIVE MEASUREMENT OF RESTING CARDIAC-OUTPUT IN MAN
    HARGREAVES, M
    JENNINGS, G
    CLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY, 1983, 10 (05) : 609 - 614
  • [34] NON-INVASIVE DETERMINATION AND VALIDATION OF CARDIAC-OUTPUT OBTAINED BY A NONIMAGING CARDIAC PROBE (NUCLEAR STETHOSCOPE)
    ADDONIZIO, LJ
    DONNELLY, CM
    CRITICAL CARE MEDICINE, 1985, 13 (04) : 364 - 364
  • [35] Non-invasive cardiac output monitoring in children: clinical validation
    Y Vandormael
    T Vu
    M Gewillig
    D Vlasselaers
    Critical Care, 14 (Suppl 1):
  • [36] Better Thanthermodiluation: Validation of Foreign Gas Rebreathing for Noninvasive Measurement of Cardiac Output in Clinical Practice
    Stoller, Douglas
    Sarma, Satyam
    Lawley, Justin
    Howden, Erin
    Levine, Benjamin D.
    JOURNAL OF CARDIAC FAILURE, 2016, 22 (08) : S17 - S17
  • [37] Non-invasive cardiac output monitoring (NICOM) in adult congenital heart disease patients with Fontan palliation
    Quain, Angela
    Hoyer, Mark
    Ephrem, Georges
    Kay, W. Aaron
    INTERNATIONAL JOURNAL OF CARDIOLOGY CONGENITAL HEART DISEASE, 2021, 6
  • [38] NON-INVASIVE DETERMINATION OF CARDIAC-OUTPUT IN PATIENTS WITH PULMONARY-DISEASES
    STEWART, RI
    LEWIS, CM
    SOUTH AFRICAN MEDICAL JOURNAL, 1981, 60 (05): : 220 - 220
  • [39] NON-INVASIVE METHOD FOR THE MEASUREMENT OF CARDIAC-OUTPUT
    NARUMI, J
    SUMA, K
    OHE, Y
    IWABUCHI, K
    UCHIYAMA, A
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1982, 46 (08): : 801 - 802
  • [40] Noninvasive Cardiac Output Determination for Children by the Inert Gas-Rebreathing Method
    Gesa Wiegand
    Gunter Kerst
    Winfried Baden
    Michael Hofbeck
    Pediatric Cardiology, 2010, 31 : 1214 - 1218