Validation of the use of foreign gas rebreathing method for non-invasive determination of cardiac output in heart disease patients.

被引:28
|
作者
Dong L. [1 ]
Wang J.A. [1 ]
Jiang C.Y. [1 ]
机构
[1] Department of Cardiology, Sir Run Run Shaw Hospital, School of Medicine, Zhejiang University, Hangzhou
来源
关键词
Indirect Fick (foreign gas rebreathing); Swan-Ganz; Cardiac output; Left ventricle radiography; Echocardiography; R543.3;
D O I
10.1631/jzus.2005.B1157
中图分类号
学科分类号
摘要
OBJECTIVE: To compare a new device (Innocor) for non-invasive measurement of cardiac output (CO) by foreign gas rebreathing method with conventional techniques used in the measurements of cardiac function. METHODS: Cardiac outputs measured by Innocor (CO(RB)) were compared with CO obtained by echocardiography (CO(EC)), Swan-Ganz thermodilution (CO(TD)), and left ventricle radiography (CO(LVR)) in 34 patients subjected to cardiac catheterization. Values obtained from the four methods were analyzed by linear regression and paired values were compared by the method of Bland and Altman in SPSS. RESULTS: There was strong positive correlation (r=0.94) between Innocor cardiac output values and the corresponding values obtained by thermodilution and between CO(EC) and CO(LVR) values. Thermodilution appears to overestimate cardiac output when compared to the values obtained with Innocor by (0.66+/-0.22) L/min (P<0.0001). There was no correlation between data obtained by Innocor and the corresponding CO(EC) and CO(LVR) values. CONCLUSION: Innocor CO(RB) is an easy, safe and well established method for non-invasive measurement of cardiac output with good prospects for clinical application in heart disease patients.
引用
收藏
页码:1157 / 1162
页数:5
相关论文
共 50 条
  • [21] NON-INVASIVE DETERMINATION OF CARDIAC-OUTPUT BY CO2 REBREATHING - VALIDITY IN AIRWAY-OBSTRUCTION (COPD) AND CARDIAC DISEASE
    MAHLER, DA
    MATTHAY, RA
    SNYDER, P
    ZARET, B
    LOKE, J
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1981, 13 (02): : 104 - 104
  • [22] NON-INVASIVE DOPPLER DETERMINATION OF CARDIAC-OUTPUT IN MAN - CLINICAL VALIDATION
    HUNTSMAN, LL
    STEWART, DK
    BARNES, SR
    FRANKLIN, SB
    COLOCOUSIS, JS
    HESSEL, EA
    CIRCULATION, 1983, 67 (03) : 593 - 602
  • [23] A Non-Invasive Assessment of Cardiac Output in Pediatric Heart Transplant Patients
    Likes, M. L.
    Alejos, J. C.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2010, 29 (02): : S172 - S172
  • [24] CONSISTENCY OF CARBON-DIOXIDE REBREATHING AS A NON-INVASIVE METHOD TO DETERMINE EXERCISE CARDIAC-OUTPUT
    KNOWLTON, RG
    ADAMS, GE
    ERGONOMICS, 1974, 17 (02) : 241 - 248
  • [25] Non-invasive measurement of cardiac output in patients with chronic heart failure
    Leslie, SJ
    McKee, S
    Newby, DE
    Webb, DJ
    Denvir, MA
    BLOOD PRESSURE MONITORING, 2004, 9 (05) : 277 - 280
  • [26] The non-invasive acetylene rebreathing method for estimation of cardiac output: Influence of breath-by-breath variation
    Hansen, S
    Wendelboe, O
    Christensen, P
    CLINICAL PHYSIOLOGY, 1997, 17 (02): : 193 - 202
  • [27] Non-invasive cardiac output monitor validation study in pediatric cardiac surgery patients
    Tirotta, Christopher F.
    Lagueruela, Richard G.
    Madril, Danielle
    Velis, Evelio
    Ojito, Jorge
    Monroe, Daniel
    Aguero, David
    Irizarry, Marysory
    McBride, John
    Hannan, Robert L.
    Burke, Redmond P.
    JOURNAL OF CLINICAL ANESTHESIA, 2017, 38 : 129 - 132
  • [29] NON-INVASIVE ASSESSMENT OF CARDIAC OUTPUT USING AN INERT GAS REBREATHING DEVICE: REPEATABILITY AND REPRODUCIBILITY IN NORMAL CONTROLS
    Corte, T. J.
    Wort, S. J.
    Ward, S.
    Cramer, D.
    Wells, A. U.
    THORAX, 2008, 63 : A127 - A127
  • [30] CORRELATION BETWEEN INVASIVE AND NON-INVASIVE CARDIAC OUTPUT ASSESSMENT IN HEART TRANSPLANT PATIENTS
    Al-Subu, Awni
    Cheifetz, Ira
    Lodge, Andrew
    Hornik, Christoph
    Ofori-Amanfo, George
    CRITICAL CARE MEDICINE, 2014, 42 (12)