Tainá Olivieri Chaves
Akira Iwahara
Luiz Tauhata
Eduarda Alexandre Rezende
Amanda Ribeiro Correia
Estela Maria de Oliveira
机构
[1] Laboratório Nacional de Metrologia das Radiações Ionizantes (LNMRI)/Instituto de Radioproteção e Dosimetria (IRD)/Comissão Nacional de Energia Nuclear (CNEN),
[2] Fundação Carlos Chagas Filho de Amparo à Pesquisa do Estado do Rio de Janeiro (FAPERJ),undefined
关键词
Nuclear medicine; Activity standardization; Ionization chamber; I capsules;
D O I
暂无
中图分类号
学科分类号
摘要
The radionuclide 131I has been increasingly used in nuclear medicine therapy procedures. Nowadays, the 131I source administered to the patient is manufactured in two different geometries: solution and capsules. The purpose of this study is the accurate measurement of the activity present in a 131I capsule without destroys it. The methodology to determine the capsules activity is to obtain the calibration factor of an IG12 secondary standard activity measurement system based on the IG12 well-type ionization chamber set up at Brazilian national metrology laboratory for ionizing radiation (LNMRI) of institute of radiation protection and dosimetry (IRD).The result obtained, 6.4670 ± 0.0381 × 10−18 A Bq−1, is quite similar to the calibration factor of the 131I solution contained in the standard ampoule geometry, 6.4515 ± 0.0368 × 10−18 A Bq−1. After obtaining the calibration factor it was used to measure 131I therapy capsules in order to check the performance of radionuclide calibrators of some Brazilian nuclear medicine centers.
引用
收藏
页码:211 / 216
页数:5
相关论文
共 49 条
  • [31] 131I and 99mTc in Effluents from a Nuclear Medicine Facility and Associated Sewage Treatment Unit
    do Carmo, Alessander Sa
    Vianello, Elizabeth Aparecida
    Pereira, Wagner
    de Macedo, Evangelina Marcia Lima
    Filho, Lucas Gomes Padilha
    de Souza, Sergio Augusto Lopes
    da Silva, Ademir Xavier
    WATER AIR AND SOIL POLLUTION, 2021, 232 (04):
  • [32] I-131 diagnosis and therapy capsules and low dose rate I-125 and Cs-137 brachytherapy sources. Calibration of the NPL secondary standard radionuclide calibrator
    Paton-Walsh, C
    Woods, M
    Sephton, JP
    Woods, SA
    Lucas, SEM
    Rossiter, MJ
    Williams, TT
    Bass, GA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 369 (2-3): : 703 - 708
  • [33] Is Thyroid Screening Necessary for Nuclear Medicine Personnel Receiving and Administering Capsules Containing Large Doses of I-131?
    Gulenchyn, Karen Y.
    Webber, Colin E.
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2009, 40 (02) : 60 - 63
  • [34] Calculation of calibration figures and the volume correction factors for 90Y, 125I, 131I and 177Lu radionuclides based on Monte-Carlo ionization chamber simulation method
    Kryeziu, D.
    Tschurlovits, M.
    Kreuziger, M.
    Maringer, F.-J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01): : 250 - 253
  • [35] Genotoxicity Associated with 131I and 99mTc Exposure in Nuclear Medicine Staff: A Physical and Biological Monitoring Study
    Miszczyk, Justyna
    Galas, Aleksander
    Panek, Agnieszka
    Kowalska, Aldona
    Kostkiewicz, Magdalena
    Borkowska, Eliza
    Brudecki, Kamil
    CELLS, 2022, 11 (10)
  • [36] EFFICIENCY OF MARKETABLE DECONTAMINATION AGENT AND GRAPHENE OXIDE ON 99mTc AND 131I SPILLAGES IN NUCLEAR MEDICINE DEPARTMENT
    Razab, Mohammad Khairul Azhar Abdul
    Nawi, Norazlina Mat
    Sunaiwi, Rosidah
    Noor, An'amt Mohamed
    Aziz, Mohd Zahri Abdul
    Hadzuan, Fara Hana Mohd
    Ibrahim, Fathirah
    Khaizul, Ahmad Thaifur
    Abdullah, Nor Hakimin
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2022, 37 (02): : 159 - 166
  • [37] Calibration of the NPL secondary standard radionuclide calibrator for 125I seeds used for prostate brachytherapy
    Baker, M
    Bass, GA
    Woods, MJ
    APPLIED RADIATION AND ISOTOPES, 2002, 56 (1-2) : 321 - 325
  • [38] Monte Carlo simulations of ceiling scatter in nuclear medicine: 99m Tc, 131I and 18F
    Schnerr, Roald S.
    de Jong, Anouk N.
    Landry, Guillaume
    Jeukens, Cecile R. L. P. N.
    Wierts, Roel
    MEDICAL PHYSICS, 2017, 44 (03) : 1113 - 1119
  • [39] Medical activated charcoal tablets as a cheap tool for passive monitoring of gaseous 131I activity in air of nuclear medicine departments
    Tomasz Mróz
    Kamil Brudecki
    Jerzy W. Mietelski
    Mirosław Bartyzel
    Ryszard Misiak
    Andrzej Kornas
    Journal of Radioanalytical and Nuclear Chemistry, 2018, 318 : 723 - 726
  • [40] Medical activated charcoal tablets as a cheap tool for passive monitoring of gaseous 131I activity in air of nuclear medicine departments
    Mroz, Tomasz
    Brudecki, Kamil
    Mietelski, Jerzy W.
    Bartyzel, Miroslaw
    Misiak, Ryszard
    Kornas, Andrzej
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2018, 318 (01) : 723 - 726