摘要
The radionuclide 131I has been increasingly used in nuclear medicine therapy procedures. Nowadays, the 131I source administered to the patient is manufactured in two different geometries: solution and capsules. The purpose of this study is the accurate measurement of the activity present in a 131I capsule without destroys it. The methodology to determine the capsules activity is to obtain the calibration factor of an IG12 secondary standard activity measurement system based on the IG12 well-type ionization chamber set up at Brazilian national metrology laboratory for ionizing radiation (LNMRI) of institute of radiation protection and dosimetry (IRD).The result obtained, 6.4670 ± 0.0381 × 10−18 A Bq−1, is quite similar to the calibration factor of the 131I solution contained in the standard ampoule geometry, 6.4515 ± 0.0368 × 10−18 A Bq−1. After obtaining the calibration factor it was used to measure 131I therapy capsules in order to check the performance of radionuclide calibrators of some Brazilian nuclear medicine centers.
引用
收藏
页码:211 / 216
页数:5
相关论文
共 49 条
  • [11] Internal dosimetry of nuclear medicine workers through the analysis of 131I in aerosols
    Carneiro, Luana Gomes
    de Lucena, Eder Augusto
    Sampaio, Camilla da Silva
    Almeida Dantas, Ana Leticia
    Sousa, Wanderson Oliveira
    Santos, Maristela Souza
    Dantas, Bernardo Maranhao
    APPLIED RADIATION AND ISOTOPES, 2015, 100 : 70 - 74
  • [12] National intercomparisons of 131I radioactivity measurements in nuclear medicine centres in India
    Joseph, L
    Anuradha, R
    Nathuram, R
    Shaha, VV
    Abani, MC
    APPLIED RADIATION AND ISOTOPES, 2003, 59 (5-6) : 359 - 362
  • [13] Calibration and consistency of results of an ionization-chamber secondary standard measuring system for activity
    Schrader, H
    APPLIED RADIATION AND ISOTOPES, 2000, 52 (03) : 325 - 334
  • [14] Intercomparison of radionuclide calibrators used in the main Lithuanian hospitals with the secondary standard ionization chamber
    Skovorodko, K.
    Gudelis, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S799 - S799
  • [15] A methodology for auto-monitoring of internal contamination by 131I in nuclear medicine workers
    Vidal, M. V. S.
    Dantas, A. L. A.
    Dantas, B. M.
    RADIATION PROTECTION DOSIMETRY, 2007, 125 (1-4) : 483 - 487
  • [16] PREPARATION OF 131I LABELED DIETHYLSTILBESTROL DIPHOSPHATE AND ITS POTENTIAL USE IN NUCLEAR MEDICINE
    TUBIS, M
    ENDOW, JS
    BLAHD, WH
    NUCLEAR-MEDIZIN, 1967, 6 (01): : 1 - &
  • [17] Intercomparison of 131I measurements using dose calibrator in nuclear medicine services of Thailand
    Soodprasert, T
    Nunthawarasilp, T
    Proceedings of 44th Kasetsart University Annual Conference: AGRICULTURAL SCIENCE: CARRYING FORWARD THE ROYAL BIO-ENERGY INITIATIVE, 2006, : 260 - 266
  • [18] National comparison of 131I measurement among nuclear medicine clinics of eight countries
    Olsovcova, Veronika
    Iwahara, Akira
    Oropesa, Pilar
    Joseph, Leena
    Ravindra, Anuradha
    Ghafoori, Mostafa
    Son, Hye-Kyung
    Sahagia, Maria
    Tastan, Selma
    Zimmerman, Brian
    APPLIED RADIATION AND ISOTOPES, 2010, 68 (7-8) : 1371 - 1377
  • [19] Calibration of Traceable Solid Mock 131I Phantoms Used in an International SPECT Image Quantification Comparison
    Zimmerman, B. E.
    Pibida, L.
    King, L. E.
    Bergeron, D. E.
    Cessna, J. T.
    Mille, M. M.
    JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 2013, 118 : 359 - 374
  • [20] Intercomparison of 131I and 99mTc activity measurements in Brazilian nuclear medicine services
    Iwahara, A
    De Oliveira, AE
    Tauhata, L
    da Silva, CJ
    Lopes, RT
    APPLIED RADIATION AND ISOTOPES, 2001, 54 (03) : 489 - 496