Analysis and processing of laser Doppler perfusion monitoring signals recorded from the beating heart

被引:0
|
作者
M. G. D. Karlsson
H. Casimir-Ahn
U. Lönn
K. Wårdell
机构
[1] Linköpings universitet,Department of Biomedical Engineering & Competence Center Noninvasive Medical Measurements (NIMED)
[2] University Hospital,Linköping Heart Center
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Laser Doppler perfusion monitoring (LDPM) can be used for monitoring myocardial perfusion in the non-beating heart. However, the movement of the beating heart generates large artifacts. Therefore the aim of the study was to develop an LDPM system capable of correlating the laser Doppler signals to the cardiac cycle and to process the signals to reduce the movement artifacts. Measurements were performed on three calves, both on the normal beating heart and during occlusion of the left anterior descending coronary artery (LAD). The recorded LDPM signals were digitally processed and correlated to the sampled ECG. Large variations in the output (perfusion) and DC signals during the cardiac cycle were found, with average coefficients of variation of 0.36 and 0.14 (n-14), respectively. However, sections with a relatively low, stable output signal were found in late diastole, where the movement of the heart is at a minimum. Occlusion of the LAD showed the importance of recording the laser Doppler signals at an appropriate point in the cardiac cycle, in this case late systole, to minimise movement artifacts. It is possible to further reduce movement artifacts by increasing the lower cutoff frequency when calculating the output signal.
引用
收藏
页码:255 / 262
页数:7
相关论文
共 50 条
  • [31] The sources of laser Doppler blood-flow signals recorded from vital and root canal treated teeth
    Polat, S
    Er, K
    Akpinar, KE
    Polat, NT
    ARCHIVES OF ORAL BIOLOGY, 2004, 49 (01) : 53 - 57
  • [32] Reduced cerebral embolic signals in beating heart coronary surgery detected by transcranial Doppler ultrasound
    Watters, MPR
    Cohen, AM
    Monk, CR
    Angelini, GD
    Ryder, IG
    BRITISH JOURNAL OF ANAESTHESIA, 2000, 84 (05) : 629 - 631
  • [33] SIGNAL-PROCESSING FOR A LASER-DOPPLER BLOOD PERFUSION METER
    KOELINK, MH
    DEMUL, FFM
    LEERKOTTE, B
    GREVE, J
    JENTINK, HW
    GRAAFF, R
    DASSEL, ACM
    AARNOUDSE, JG
    SIGNAL PROCESSING, 1994, 38 (02) : 239 - 252
  • [34] Mucosal blood flow measurements using laser Doppler perfusion monitoring
    Dag Arne Lihaug Hoff
    Hans Gregersen
    Jan Gunnar Hatlebakk
    World Journal of Gastroenterology, 2009, 15 (02) : 198 - 203
  • [35] The influence of probe fiber distance on laser Doppler perfusion monitoring measurements
    Morales, F
    Graaff, R
    Smit, AJ
    Gush, R
    Rakhorst, G
    MICROCIRCULATION, 2003, 10 (05) : 433 - 441
  • [36] Mucosal blood flow measurements using laser Doppler perfusion monitoring
    Hoff, Dag Arne Lihaug
    Gregersen, Hans
    Hatlebakk, Jan Gunnar
    WORLD JOURNAL OF GASTROENTEROLOGY, 2009, 15 (02) : 198 - 203
  • [37] Monitoring perfusion changes in laser-treated tumors using laser Doppler flowmetry
    Deans, Abby
    Hess, Linda
    Koss, Michael
    Liu, Hong
    Chen, Wei R.
    OPTICAL INTERACTIONS WITH TISSUE AND CELLS XVII, 2006, 6084
  • [38] Analysis of timing events in Doppler ultrasound signals from the fetal heart rate
    Zietek, J.
    Jezewski, J.
    Horoba, K.
    Gacek, A.
    Wrobel, J.
    CIRCULATION, 2008, 118 (12) : E179 - E180
  • [39] Myocardial tissue motion influence on laser Doppler perfusion monitoring using tissue Doppler imaging
    M. G. D. Karlsson
    L. Hübbert
    U. Lönn
    B. Janerot-Sjöberg
    H. Casimir-Ahn
    K. Wårdell
    Medical and Biological Engineering and Computing, 2004, 42 : 770 - 776
  • [40] Myocardial tissue motion influence on laser Doppler perfusion monitoring using tissue Doppler imaging
    Karlsson, MGD
    Hübbert, L
    Lönn, U
    Janerot-Sjöberg, B
    Casimir-Ahn, H
    Wårdell, K
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2004, 42 (06) : 770 - 776