Functional outcomes of the failed plate fixation in distal tibial fractures salvaged by hexapod external fixator

被引:6
|
作者
Molepo M. [1 ]
Barnard A.-C. [2 ]
Birkholtz F. [1 ,2 ]
Tetsworth K. [3 ,4 ,5 ,6 ]
Glatt V. [6 ,7 ]
Hohmann E. [8 ,9 ]
机构
[1] Department of Orthopaedic Surgery, University of Pretoria, Pretoria
[2] Walk-A-Mile Centre for Advanced Orthopaedics, Centurion, Pretoria
[3] Department of Orthopaedic Surgery, Royal Brisbane Hospital, Brisbane
[4] Department of Surgery, School of Medicine, University of Queensland, Brisbane
[5] Queensland University of Technology, Brisbane
[6] Orthopaedic Research Centre of Australia, Brisbane
[7] University of Texas Health Science Center, San Antonio, Tx
[8] School of Medicine, University of Pretoria, Pretoria
[9] Department of Orthopaedic Surgery and Sports Medicine, Valiant Clinic/Houston Methodist Group, PO Box 414296, Dubai
关键词
Circular external fixation; Distal tibial fractures; Hexapod; Non-union; Plate fixation;
D O I
10.1007/s00590-018-2231-x
中图分类号
学科分类号
摘要
Purpose: The purpose of this study was to evaluate the clinical and functional outcomes of failed plate fixation in distal tibia fractures salvaged with hexapod circular fixators. Materials and methods: The database of a specialized limb reconstruction center was searched for all patients with failed plate fixation undergoing limb reconstruction with a circular external fixator between 2008 and 2017. Patients between the ages of 18–65 years, with a symptomatic distal tibia malunion or non-union following plate and screw fixation were included. The SF-12 and Foot Function Index (FFI) scoring systems were used to measure clinical and functional outcomes. Results: Ten patients with a mean age of 38 ± 13 years met the inclusion criteria. Seven patients had an infected non-union, two hypertrophic non-unions, and one a malunion. The mean follow-up was 41.7 ± 28.3 months. The mean duration of external fixation was 232.9 ± 146.6 days. The SF-12 demonstrated a mean score of 49.4 ± 7.7 for the physical component and a mean score of 55.3 ± 8.1 for the mental component. Five patients (50%) scored above 45 points for the SF12 physical component, and nine patients (90%) scored above 45 points for the mental component, indicating good outcome can be achieved. The mean FFI score was 24.9 ± 19.9, and six patients had a score below 14 points (good outcome). Radiological union was observed in all 10 patients at a mean of 29 ± 14 months. Conclusions: The results of this study suggest that hexapod circular external fixation is an attractive surgical alternative for the treatment of failed plate fixation of distal tibial fractures, and can reliably achieve bony union and result in very satisfactory clinical outcomes. Level of Evidence: Level IV case series. © 2018, Springer-Verlag France SAS, part of Springer Nature.
引用
收藏
页码:1617 / 1624
页数:7
相关论文
共 50 条
  • [31] HUGHES EXTERNAL FIXATOR IN TREATMENT OF TIBIAL FRACTURES
    COURTBROWN, CM
    HUGHES, SPF
    JOURNAL OF THE ROYAL SOCIETY OF MEDICINE, 1985, 78 (10) : 830 - 837
  • [32] Locking internal fixator with minimally invasive plate osteosynthesis for the proximal and distal tibial fractures
    Tong Da-ke
    Ji Fang
    Cai Xiao-bing
    CHINESE JOURNAL OF TRAUMATOLOGY, 2011, 14 (04) : 233 - 236
  • [33] Locking internal fixator with minimally invasive plate osteosynthesis for the proximal and distal tibial fractures
    TONG DakeJI Fang and CAI Xiaobing Department of OrthopaedicsChanghai HospitalSecond Military UniversityShanghai China
    中华创伤杂志(英文版), 2011, (04)
  • [34] Distal medial tibial locking plate for fixation of extraarticular distal humeral fractures; an alternative choice for fixation
    Yorukoglu, Ali Cagdas
    Demirkan, Ahmet Fahir
    Buker, Nihal
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2018, 52 (04) : 294 - 298
  • [35] COMBINED PLATE VERSUS EXTERNAL FIXATION FOR DISTAL RADIUS FRACTURES
    Polat, Oktay
    Toy, Serdar
    Ozbay, Hakan
    ACTA ORTOPEDICA BRASILEIRA, 2023, 31
  • [36] External Fixation of Tibial Fractures
    Tejwani, Nirmal
    Polonet, David
    Wolinsky, Philip R.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2015, 23 (02) : 126 - 130
  • [37] Outcomes and Complications With Treatment of Open Tibial Plafond Fractures With Circular External Fixator
    Thabet, Ahmed M.
    Gerzina, Christopher
    Sala, Francesco
    Jeon, Soyoung
    Lovisetti, Giovanni
    Abdelgawad, Amr
    DeCoster, Thomas A.
    Azzam, Wael
    FOOT & ANKLE INTERNATIONAL, 2021, 42 (06) : 723 - 733
  • [38] The Radiological and Functional Outcomes of Pelvic Fractures Treated by External Fixator
    Bux, Husain
    Imamuddin
    Azeem, Nazia
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2021, 15 (10): : 3458 - 3459
  • [39] The service impact of failed locking plate fixation of distal tibial fractures: a service and financial evaluation at a major trauma centre
    Kent M.
    Mumith A.
    McEwan J.
    Hancock N.
    European Journal of Orthopaedic Surgery & Traumatology, 2015, 25 (8) : 1333 - 1342
  • [40] Hexapod External Fixation of Tibia Fractures in Children
    Iobst, Christopher A.
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2016, 36 (04) : S24 - S28