Functional outcomes of the failed plate fixation in distal tibial fractures salvaged by hexapod external fixator

被引:6
|
作者
Molepo M. [1 ]
Barnard A.-C. [2 ]
Birkholtz F. [1 ,2 ]
Tetsworth K. [3 ,4 ,5 ,6 ]
Glatt V. [6 ,7 ]
Hohmann E. [8 ,9 ]
机构
[1] Department of Orthopaedic Surgery, University of Pretoria, Pretoria
[2] Walk-A-Mile Centre for Advanced Orthopaedics, Centurion, Pretoria
[3] Department of Orthopaedic Surgery, Royal Brisbane Hospital, Brisbane
[4] Department of Surgery, School of Medicine, University of Queensland, Brisbane
[5] Queensland University of Technology, Brisbane
[6] Orthopaedic Research Centre of Australia, Brisbane
[7] University of Texas Health Science Center, San Antonio, Tx
[8] School of Medicine, University of Pretoria, Pretoria
[9] Department of Orthopaedic Surgery and Sports Medicine, Valiant Clinic/Houston Methodist Group, PO Box 414296, Dubai
关键词
Circular external fixation; Distal tibial fractures; Hexapod; Non-union; Plate fixation;
D O I
10.1007/s00590-018-2231-x
中图分类号
学科分类号
摘要
Purpose: The purpose of this study was to evaluate the clinical and functional outcomes of failed plate fixation in distal tibia fractures salvaged with hexapod circular fixators. Materials and methods: The database of a specialized limb reconstruction center was searched for all patients with failed plate fixation undergoing limb reconstruction with a circular external fixator between 2008 and 2017. Patients between the ages of 18–65 years, with a symptomatic distal tibia malunion or non-union following plate and screw fixation were included. The SF-12 and Foot Function Index (FFI) scoring systems were used to measure clinical and functional outcomes. Results: Ten patients with a mean age of 38 ± 13 years met the inclusion criteria. Seven patients had an infected non-union, two hypertrophic non-unions, and one a malunion. The mean follow-up was 41.7 ± 28.3 months. The mean duration of external fixation was 232.9 ± 146.6 days. The SF-12 demonstrated a mean score of 49.4 ± 7.7 for the physical component and a mean score of 55.3 ± 8.1 for the mental component. Five patients (50%) scored above 45 points for the SF12 physical component, and nine patients (90%) scored above 45 points for the mental component, indicating good outcome can be achieved. The mean FFI score was 24.9 ± 19.9, and six patients had a score below 14 points (good outcome). Radiological union was observed in all 10 patients at a mean of 29 ± 14 months. Conclusions: The results of this study suggest that hexapod circular external fixation is an attractive surgical alternative for the treatment of failed plate fixation of distal tibial fractures, and can reliably achieve bony union and result in very satisfactory clinical outcomes. Level of Evidence: Level IV case series. © 2018, Springer-Verlag France SAS, part of Springer Nature.
引用
收藏
页码:1617 / 1624
页数:7
相关论文
共 50 条
  • [21] Management of high-energy tibial shaft fractures using the hexapod circular external fixator
    Liu, Yanshi
    Liu, Jialin
    Yushan, Maimaiaili
    Liu, Zhenhui
    Zhang, Tao
    Ma, He
    Ma, Chuang
    Yusufu, Aihemaitijiang
    BMC SURGERY, 2021, 21 (01)
  • [22] Management of feline distal tibial fractures using a hybrid external skeletal fixator
    Witte, P. G.
    Bush, M. A.
    Scott, H. W.
    JOURNAL OF SMALL ANIMAL PRACTICE, 2014, 55 (11) : 571 - 578
  • [23] Management of Nonunion of Distal Tibial Periarticular Fractures Using Ilizarov External Fixator
    Zayda, Ahmed
    Badr, Ismail Tawfeek
    TECHNIQUES IN FOOT AND ANKLE SURGERY, 2024, 23 (01): : 12 - 20
  • [24] Fixator-assisted Percutaneous Plate Fixation of Complex Diaphyseal Tibial Fractures
    Nada, Abdullah A.
    Romeih, Mohamed
    El-Rosasy, Mahmoud
    STRATEGIES IN TRAUMA AND LIMB RECONSTRUCTION, 2019, 14 (01) : 25 - 28
  • [25] External Fixation Versus "π" Plate for Distal Radius Fractures
    Kateros, Konstantinos
    Macheras, George
    Galanakos, Spyros P.
    Sofianos, Ioannis
    Papakostas, Ioannis
    Papadakis, Stamatios A.
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2010, 68 (01): : 166 - 172
  • [26] Open Reduction and Plate Fixation, External Fixator, and Conservative Treatment for Intra- articular Distal Radius Fractures
    Akdemir, Mehmet
    Kilic, Ali Ihsan
    Kurt, Cengizhan
    Capkin, Sercan
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (01)
  • [27] Effectiveness of external fixator combined with T-plate internal fixation for the treatment of comminuted distal radius fractures
    Han, L. R.
    Jin, C. X.
    Yan, J.
    Han, S. Z.
    He, X. B.
    Yang, X. F.
    GENETICS AND MOLECULAR RESEARCH, 2015, 14 (01) : 2912 - 2919
  • [28] Outcomes of open bicondylar tibial plateau fractures treated with Ilizarov external fixator with or without minimal internal fixation
    Ali A.M.
    European Journal of Orthopaedic Surgery & Traumatology, 2013, 23 (3) : 349 - 355
  • [29] Distal humerus nonunions after failed internal fixation - treatment with the Ilizarov external fixator
    Tomic, Slavko
    Baljozovic, Andreja
    SRPSKI ARHIV ZA CELOKUPNO LEKARSTVO, 2018, 146 (3-4) : 169 - 173
  • [30] Tibial Pilon fractures Internal plate fixation versus external wire fixation
    Suthorn Bavonratanavech
    Ian Harris
    Beate P. Hanson
    Mohit Bhandari
    中华创伤骨科杂志, 2005, (07) : 680 - 683