Functional outcomes of the failed plate fixation in distal tibial fractures salvaged by hexapod external fixator

被引:6
|
作者
Molepo M. [1 ]
Barnard A.-C. [2 ]
Birkholtz F. [1 ,2 ]
Tetsworth K. [3 ,4 ,5 ,6 ]
Glatt V. [6 ,7 ]
Hohmann E. [8 ,9 ]
机构
[1] Department of Orthopaedic Surgery, University of Pretoria, Pretoria
[2] Walk-A-Mile Centre for Advanced Orthopaedics, Centurion, Pretoria
[3] Department of Orthopaedic Surgery, Royal Brisbane Hospital, Brisbane
[4] Department of Surgery, School of Medicine, University of Queensland, Brisbane
[5] Queensland University of Technology, Brisbane
[6] Orthopaedic Research Centre of Australia, Brisbane
[7] University of Texas Health Science Center, San Antonio, Tx
[8] School of Medicine, University of Pretoria, Pretoria
[9] Department of Orthopaedic Surgery and Sports Medicine, Valiant Clinic/Houston Methodist Group, PO Box 414296, Dubai
关键词
Circular external fixation; Distal tibial fractures; Hexapod; Non-union; Plate fixation;
D O I
10.1007/s00590-018-2231-x
中图分类号
学科分类号
摘要
Purpose: The purpose of this study was to evaluate the clinical and functional outcomes of failed plate fixation in distal tibia fractures salvaged with hexapod circular fixators. Materials and methods: The database of a specialized limb reconstruction center was searched for all patients with failed plate fixation undergoing limb reconstruction with a circular external fixator between 2008 and 2017. Patients between the ages of 18–65 years, with a symptomatic distal tibia malunion or non-union following plate and screw fixation were included. The SF-12 and Foot Function Index (FFI) scoring systems were used to measure clinical and functional outcomes. Results: Ten patients with a mean age of 38 ± 13 years met the inclusion criteria. Seven patients had an infected non-union, two hypertrophic non-unions, and one a malunion. The mean follow-up was 41.7 ± 28.3 months. The mean duration of external fixation was 232.9 ± 146.6 days. The SF-12 demonstrated a mean score of 49.4 ± 7.7 for the physical component and a mean score of 55.3 ± 8.1 for the mental component. Five patients (50%) scored above 45 points for the SF12 physical component, and nine patients (90%) scored above 45 points for the mental component, indicating good outcome can be achieved. The mean FFI score was 24.9 ± 19.9, and six patients had a score below 14 points (good outcome). Radiological union was observed in all 10 patients at a mean of 29 ± 14 months. Conclusions: The results of this study suggest that hexapod circular external fixation is an attractive surgical alternative for the treatment of failed plate fixation of distal tibial fractures, and can reliably achieve bony union and result in very satisfactory clinical outcomes. Level of Evidence: Level IV case series. © 2018, Springer-Verlag France SAS, part of Springer Nature.
引用
收藏
页码:1617 / 1624
页数:7
相关论文
共 50 条
  • [1] Correction outcomes of the postoperative malalignment salvaged by the temporary application of the hexapod external fixator in tibial diaphyseal fractures treated by monolateral external fixation
    Liu, Yanshi
    Liu, Jialin
    Zhang, Xingpeng
    Li, Hong
    Fu, Xuefei
    Liu, Qixin
    Ma, Chuang
    Yusufu, Aihemaitijiang
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2021, 52 (11): : 3478 - 3482
  • [2] Locking compression plate as an external fixator in the treatment of closed distal tibial fractures
    Zhou, Yu
    Wang, Yanbiao
    Liu, Lifeng
    Zhou, Zhenyu
    Cao, Xuecheng
    INTERNATIONAL ORTHOPAEDICS, 2015, 39 (11) : 2227 - 2237
  • [3] Locking compression plate as an external fixator in the treatment of closed distal tibial fractures
    Yu Zhou
    Yanbiao Wang
    Lifeng Liu
    Zhenyu Zhou
    Xuecheng Cao
    International Orthopaedics, 2015, 39 : 2227 - 2237
  • [4] Stiffness of the locking compression plate as an external fixator for treating distal tibial fractures: a biomechanics study
    Wei Liu
    Lihui Yang
    Xiaochuan Kong
    Likun An
    Gang Hong
    Zicheng Guo
    Lei Zang
    BMC Musculoskeletal Disorders, 18
  • [5] Stiffness of the locking compression plate as an external fixator for treating distal tibial fractures: a biomechanics study
    Liu, Wei
    Yang, Lihui
    Kong, Xiaochuan
    An, Likun
    Hong, Gang
    Guo, Zicheng
    Zang, Lei
    BMC MUSCULOSKELETAL DISORDERS, 2017, 18 : 1 - 6
  • [6] Retrospective clinical outcomes in the definitive treatment of high-energy tibial diaphyseal fractures using hexapod external fixator versus monolateral external fixator
    Liu, Yanshi
    Liu, Kai
    Cai, Feiyu
    Zhang, Xingpeng
    Li, Hong
    Zhang, Tao
    Ma, Chuang
    Yusufu, Aihemaitijiang
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [7] Retrospective clinical outcomes in the definitive treatment of high-energy tibial diaphyseal fractures using hexapod external fixator versus monolateral external fixator
    Yanshi Liu
    Kai Liu
    Feiyu Cai
    Xingpeng Zhang
    Hong Li
    Tao Zhang
    Chuang Ma
    Aihemaitijiang Yusufu
    BMC Musculoskeletal Disorders, 23
  • [8] External Fixation Using a Locking Plate: A Reliable Way in Treating Distal Tibial Fractures
    Zhang, Jingwei
    Ebraheim, Nabil A.
    Li, Ming
    He, Xianfeng
    Liu, Jiayong
    Zhu, Limei
    Yu, Yihui
    Siddiqui, Saaid
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2015, 29 (11) : e454 - e458
  • [9] External fixator as a safe method in the treatment of distal tibial fractures in children
    Wen, Yuwei
    Zhu, Danjiang
    Wang, Qiang
    Song, Baojian
    Feng, Wei
    JOURNAL OF PEDIATRIC ORTHOPAEDICS-PART B, 2024, 33 (03): : 233 - 239
  • [10] Distal tibial fractures treated with hybrid external fixation
    Babis, G. C.
    Kontovazenitis, P.
    Evangelopoulos, D. S.
    Tsailas, P.
    Nikolopoulos, K.
    Soucacos, P. N.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2010, 41 (03): : 253 - 258