Validation of 4D flow CMR against simultaneous invasive hemodynamic measurements: a swine study

被引:0
|
作者
Kelly Stam
Raluca G. Chelu
Nikki van der Velde
Richard van Duin
Piotr Wielopolski
Koen Nieman
Daphne Merkus
Alexander Hirsch
机构
[1] University Medical Center Rotterdam,Department of Cardiology, Thoraxcenter, Erasmus MC
[2] University Medical Center Rotterdam,Department of Radiology and Nuclear Medicine, Erasmus MC
关键词
4D flow CMR; Flow measurement; Invasive flow probe; Swine;
D O I
暂无
中图分类号
学科分类号
摘要
The purpose of this study was to compare invasively measured aorta flow with 2D phase contrast flow and 4D flow measurements by cardiovascular magnetic resonance (CMR) imaging in a large animal model. Nine swine (mean weight 63 ± 4 kg) were included in the study. 4D flow CMR exams were performed on a 1.5T MRI scanner. Flow measurements were performed on 4D flow images at the aortic valve level, in the ascending aorta, and main pulmonary artery. Simultaneously, flow was measured using an invasive flow probe, placed around the ascending aorta. Additionally, standard 2D phase contrast flow and 2D left ventricular (LV) volumetric data were used for comparison. The correlations of cardiac output (CO) between the invasive flow probe, and CMR modalities were strong to very strong. CO measured by 4D flow CMR correlated better with the CO measured by the invasive flow probe than 2D flow CMR flow and volumetric LV data (4D flow CMR: Spearman’s rho = 0.86 at the aortic valve level and 0.90 at the ascending aorta level; 2D flow CMR: 0.67 at aortic valve level; LV measurements: 0.77). In addition, there tended to be a correlation between mean pulmonary artery flow and aorta flow with 4D flow (Spearman’s rho = 0.65, P = 0.07), which was absent in measurements obtained with 2D flow CMR (Spearman’s rho = 0.40, P = 0.33). This study shows that aorta flow can be accurately measured by 4D flow CMR compared to simultaneously measured invasive flow. This helps to further validate the quantitative reliability of this technique.
引用
收藏
页码:1111 / 1118
页数:7
相关论文
共 50 条
  • [11] 4D flow CMR for diastolic function assessment in cardiac amyloidosis
    Pica, S.
    Piatti, F.
    Milani, P.
    Mussinelli, R.
    Foli, A.
    Basset, M.
    Camporeale, A.
    Geppert, C.
    Giese, D.
    Chow, K.
    Perlini, S.
    Merlini, G.
    Palladini, G.
    Lombardi, M.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2019, 20 : 408 - 409
  • [12] 4D Flow CMR The Final Frontier in Valvular Heart Disease?
    Shah, Dipan J.
    JACC-CARDIOVASCULAR IMAGING, 2021, 14 (07) : 1367 - 1368
  • [13] 4D flow CMR for diastolic function assessment in cardiac amyloidosis
    Pica, Silvia
    Tondi, Lara
    Piatti, Filippo
    Milani, P.
    Mussinelli, R.
    Foli, A.
    Basset, M.
    Camporeale, Antonia
    Geppert, C.
    Perlini, S.
    Merlini, G.
    Palladini, G.
    Lombardi, Massimo
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2019, 21 (0J) : J74 - J75
  • [14] Hemodynamic characteristics associated with partial thrombosis of the false lumen in patients with chronic aortic dissection of the descending aorta: a 4D flow CMR study
    Munoz, Aroa Ruiz
    Guala, Andrea
    Dux-Santoy, Lydia
    Teixido-Tura, Gisela
    Garrido-Oliver, Juan
    Garcia-Duran, Ana
    Valente, Filipa
    Galian-Gay, Laura
    Gutierrez, Laura
    Cuellar-Calabria, Hug
    Johnson, Kevin
    Wieven, Oliver
    Ferreira-Gonzalez, Ignacio
    Evangelista, Arturo
    Rodriguez-Palomares, Jose
    CARDIOVASCULAR RESEARCH, 2022, 118 (SUPP 2)
  • [15] Qualitative grading of aortic regurgitation: a pilot study comparing CMR 4D flow and echocardiography
    Chelu, Raluca G.
    van den Bosch, Annemien E.
    van Kranenburg, Matthijs
    Hsiao, Albert
    van den Hoven, Allard T.
    Ouhlous, Mohamed
    Budde, Ricardo P. J.
    Beniest, Kirsten M.
    Swart, Laurens E.
    Coenen, Adriaan
    Lubbers, Marisa M.
    Wielopolski, Piotr A.
    Vasanawala, Shreyas S.
    Roos-Hesselink, Jolien W.
    Nieman, Koen
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2016, 32 (02): : 301 - 307
  • [16] Qualitative grading of aortic regurgitation: a pilot study comparing CMR 4D flow and echocardiography
    Raluca G. Chelu
    Annemien E. van den Bosch
    Matthijs van Kranenburg
    Albert Hsiao
    Allard T. van den Hoven
    Mohamed Ouhlous
    Ricardo P. J. Budde
    Kirsten M. Beniest
    Laurens E. Swart
    Adriaan Coenen
    Marisa M. Lubbers
    Piotr A. Wielopolski
    Shreyas S. Vasanawala
    Jolien W. Roos-Hesselink
    Koen Nieman
    The International Journal of Cardiovascular Imaging, 2016, 32 : 301 - 307
  • [17] Cloud-processed 4D CMR flow imaging for pulmonary flow quantification
    Chelu, Raluca G.
    Wanambiro, Kevin W.
    Hsiao, Albert
    Swart, Laurens E.
    Voogd, Teun
    van den Hoven, Allard T.
    van Kranenburg, Matthijs
    Coenen, Adriaan
    Boccalini, Sara
    Wielopolski, Piotr A.
    Vogel, Mika W.
    Krestin, Gabriel P.
    Vasanawala, Shreyas S.
    Budde, Ricardo P. J.
    Roos-Hesselink, Jolien W.
    Nieman, Koen
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (10) : 1849 - 1856
  • [18] Automatic multi-vessel volume flow calculation with 4D flow CMR
    Mariana Bustamante
    Petter Dyverfeldt
    Sven Petersson
    Jonatan Eriksson
    Carl Johan Carlhall
    Tino Ebbers
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [19] Automated hemodynamic assessment for cranial 4D flow MRI
    Roberts, Grant S.
    Hoffman, Carson A.
    Rivera-Rivera, Leonardo A.
    Berman, Sara E.
    Eisenmenger, Laura B.
    Wieben, Oliver
    MAGNETIC RESONANCE IMAGING, 2023, 97 : 46 - 55
  • [20] 4D flow MRI hemodynamic biomarkers for cerebrovascular diseases
    Wahlin, Anders
    Eklund, Anders
    Malm, Jan
    JOURNAL OF INTERNAL MEDICINE, 2022, 291 (02) : 115 - 127