Evaluation of 3D guided electroanatomic mapping for ablation of atrial fibrillation in reference to CT-Scan image integration

被引:0
|
作者
Christian de Chillou
Marius Andronache
Ahmed Abdelaal
Yves Ernst
Isabelle Magnin-Poull
Mohamed Magdi
Ning Zhang
Samuel Tissier
Damien Mandry
Cécile Barbary
Denis Régent
Etienne Aliot
机构
[1] University Hospital Nancy,Department of Cardiology
[2] University Hospital Nancy,Department of Radiology
[3] Hôpitaux de Brabois,Département de Cardiologie
关键词
Atrial fibrillation; Electroanatomic mapping; Catheter ablation; CT scan image integration;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [21] Problematic integration errors of the use of electroanatomic mapping and CT imaging (CARTO-Merge) during catheter ablation of atrial fibrillation
    Oh, Y. S.
    Kim, J. H.
    Choi, Y. S.
    Lee, D. H.
    Park, C. S.
    Shin, W. S.
    Jang, S. W.
    Lee, M. Y.
    Rho, T. H.
    Hong, S. J.
    EUROPEAN HEART JOURNAL, 2008, 29 : 290 - 291
  • [22] Impact of Image Integration on Catheter Ablation for Atrial Fibrillation Using Three-Dimensional Electroanatomic Mapping: A Meta-Analysis
    Liu, Shan-Xin
    Zhang, Yu
    Zhang, Xing-Wei
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2012, 35 (10): : 1242 - 1247
  • [23] Real-Time Three-Dimensional Image Integration in Atrial Fibrillation Ablation: A Randomised Comparison with an Electroanatomic Mapping System
    Kriatselis, Charalampos
    Min, Tang
    Roser, Mattias
    Gerds-Li, Hong
    Fleck, Eckert
    CIRCULATION, 2008, 118 (18) : S587 - S588
  • [24] Impact of respiration gating on image integration guided atrial fibrillation ablation
    Ozcan, Emin Evren
    Szeplaki, Gabor
    Tahin, Tamas
    Osztheimer, Istvan
    Szilagyi, Szabolcs
    Apor, Astrid
    Horvath, Pal Maurovich
    Vago, Hajnalka
    Merkely, Bela
    Geller, Laszlo
    CLINICAL RESEARCH IN CARDIOLOGY, 2014, 103 (09) : 727 - 731
  • [25] Impact of respiration gating on image integration guided atrial fibrillation ablation
    Emin Evren Özcan
    Gabor Szeplaki
    Tamas Tahin
    Istvan Osztheimer
    Szabolcs Szilagyi
    Astrid Apor
    Pal Maurovich Horvath
    Hajnalka Vago
    Béla Merkely
    Laszlo Geller
    Clinical Research in Cardiology, 2014, 103 : 727 - 731
  • [26] Integration of computed tomography imaging and electroanatomic mapping to support electrophysiologically based procedures for ablation of atrial fibrillation
    De Ponti, Roberto
    Marazzi, Raffaella
    Caravati, Fabrizio
    Fantoni, Cecilia
    Mangini, Monica
    Fugazzola, Carlo
    Salerno-Uriarte, Jorge A.
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2006, 7 (12) : 884 - 885
  • [27] Process-dependent accuracy of 3D image integration for atrial fibrillation ablation: Comparison of cartomerge with 3D ICE Imaging
    Okumura, Yasuo
    Henz, Benhur D.
    Johnson, Susan B.
    Packer, Dougla L.
    CIRCULATION, 2007, 116 (16) : 489 - 489
  • [28] Three dimensional CT-scan to identify pulmonary veins anatomic variability before atrial fibrillation ablation
    Tissier, S.
    Andronache, M.
    de Chilou, C.
    Codreanu, A.
    Magnin-Poull, I.
    Ernst, Y.
    Regent, D.
    Aliot, E.
    EUROPEAN HEART JOURNAL, 2005, 26 : 33 - 33
  • [29] Catheter ablation of paroxysmal atrial fibrillation using a 3D mapping system
    Pappone, C
    Oreto, G
    Lamberti, F
    Vicedomini, G
    Loricchio, ML
    Shpun, S
    Rillo, M
    Calabrò, MP
    Conversano, A
    Ben-Haim, SA
    Cappato, R
    Chierchia, S
    CIRCULATION, 1999, 100 (11) : 1203 - 1208
  • [30] 3D Liver Segmentation from CT-Scan Images
    Sutiratanapong, Nateepat
    Sucontphunt, Tanasai
    PROCEEDINGS OF THE 20TH INTERNATIONAL CONFERENCE ON COMPUTING AND INFORMATION TECHNOLOGY, IC2IT 2024, 2024, 973 : 131 - 140