Impact of respiration gating on image integration guided atrial fibrillation ablation

被引:9
|
作者
Ozcan, Emin Evren [1 ,2 ]
Szeplaki, Gabor [1 ]
Tahin, Tamas [1 ]
Osztheimer, Istvan [1 ]
Szilagyi, Szabolcs [1 ]
Apor, Astrid [1 ]
Horvath, Pal Maurovich [1 ]
Vago, Hajnalka [1 ]
Merkely, Bela [1 ]
Geller, Laszlo [1 ]
机构
[1] Semmelweis Univ, Ctr Heart, H-1122 Budapest, Hungary
[2] Sifa Univ, Dept Cardiol, Izmir, Turkey
关键词
Respiration gating; Atrial fibrillation; Catheter ablation; Pulmonary vein isolation; Electroanatomical mapping; RADIOFREQUENCY CATHETER ABLATION; RADIATION-EXPOSURE; FLUOROSCOPY EXPOSURE; NAVIGATION SYSTEM; PULMONARY VEINS; PROCEDURE DURATION; CONTACT FORCE; REDUCTION; ACCURACY; REGISTRY;
D O I
10.1007/s00392-014-0707-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Radiofrequency (RF) catheter ablation guided by electroanatomic mapping systems is an effective therapy for atrial fibrillation. However, it may be affected by respiration movements. The aim of this study was to determine the impact of respiratory gating on procedural parameters in patients undergoing catheter ablation of atrial fibrillation (AF). One-hundred forty consecutive patients undergoing pulmonary vein isolation were admitted to study. Respiratory gating module (AccuResp algorithm, Carto3, Biosense Webster) was enabled in 70 patients and disabled in 70 patients during procedures. Successful pulmonary vein isolation and sinus rhythm were obtained in all patients. A significant reduction in total procedure times [median 77, interquartile range (IQR 66-95) min vs median 82 (IQR 72-104) min, p < 0.05] and fluoroscopy times [median 14 (IQR 9-17) min vs median 16 (IQR 12-22) min, p < 0.05] were observed in the respiratory gated group. Although ablation times (duration between the first and last ablation) were significantly shorter in respiratory gated group [median 37 (IQR 32-53) min vs median 48 (IQR 39-65) min, p < 0.05], total RF application durations were not different between two groups [median 1,554 (IQR 1,213-2,196) s vs median 1,802 (IQR 1,344-2,448) s, p = 0.11]. Difference in electroanatomical map reconstruction times was not significant [median 14 (IQR 12-16) min in gated group vs median 13 (IQR 10-18) min in nongated group, p = 0.19]. Respiratory gating significantly improves fluoroscopy and ablation times during electroanatomic mapping guided AF ablation. Respiratory gated maps may provide uninterrupted continuous ablation applications. Furthermore, using automatic respiratory gating module does not prolong mapping times.
引用
收藏
页码:727 / 731
页数:5
相关论文
共 50 条
  • [1] Impact of respiration gating on image integration guided atrial fibrillation ablation
    Emin Evren Özcan
    Gabor Szeplaki
    Tamas Tahin
    Istvan Osztheimer
    Szabolcs Szilagyi
    Astrid Apor
    Pal Maurovich Horvath
    Hajnalka Vago
    Béla Merkely
    Laszlo Geller
    Clinical Research in Cardiology, 2014, 103 : 727 - 731
  • [2] Changes in left atrial anatomy due to respiration:: Impact on three-dimensional image integration during atrial fibrillation ablation
    Ector, Joris
    De Buck, Stijn
    Loeckx, Dirk
    Coudyzer, Walter
    Maes, Frederik
    Dymarkowski, Steven
    Bogaert, Jan
    Heidbuchelel, Hein
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2008, 19 (08) : 828 - 834
  • [3] Image integration in catheter ablation of atrial fibrillation
    Tops, Laurens F.
    Schalij, Martin J.
    den Uijl, Dennis W.
    Abraham, Theodore P.
    Calkins, Hugh
    Bax, Jeroen J.
    EUROPACE, 2008, 10 : 48 - 56
  • [4] Image Integration-Guided Catheter Ablation of Atrial Fibrillation: A Prospective Randomized Study
    Della Bella, Paolo
    Fassini, Gaetano
    Cireddu, Manuela
    Riva, Stefania
    Carbucicchio, Corrado
    Giraldi, Francesco
    Maccabelli, Giuseppe
    Trevisi, Nicola
    Moltrasio, Massimo
    Pepi, Mauro
    Galli, Claudia A.
    Andreini, Daniele
    Ballerini, Giovanni
    Pontone, Gianluca
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2009, 20 (03) : 258 - 265
  • [5] Cardiac image integration implications for atrial fibrillation ablation
    Jasbir Sra
    Journal of Interventional Cardiac Electrophysiology, 2008, 22 : 145 - 154
  • [6] Cardiac image integration implications for atrial fibrillation ablation
    Sra, Jasbir
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2008, 22 (02) : 145 - 154
  • [7] Ablation of atrial fibrillation using CT image integration
    Degener S.
    Shin D.-I.
    Pattberg S.V.
    Stamm I.
    Tonnellier B.
    Horlitz M.
    Wiener Medizinische Wochenschrift, 2008, 158 (5-6) : 148 - 151
  • [8] Computed tomography-fluoroscopy image integration-guided catheter ablation of atrial fibrillation
    Sra, Jasbir
    Narayan, Girish
    Krum, David
    Malloy, Angela
    Cooley, Ryan
    Bhatia, Atul
    Dhala, Anwer
    Blanck, Zalmen
    Nangia, Vikram
    Akhtar, Masood
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2007, 18 (04) : 409 - 414
  • [9] Image integration for atrial fibrillation ablation-pearls and pitfalls
    Kistler, Peter M.
    Schilling, Richard J.
    Rajappan, Kim
    Sporton, Simon C.
    HEART RHYTHM, 2007, 4 (09) : 1216 - 1221
  • [10] The impact of the CartoSound® image directly acquired from the left atrium for integration in atrial fibrillation ablation
    Kaseno, Kenichi
    Hisazaki, Kaori
    Nakamura, Kohki
    Ikeda, Etsuko
    Hasegawa, Kanae
    Aoyama, Daisetsu
    Shiomi, Yuichiro
    Ikeda, Hiroyuki
    Morishita, Tetsuji
    Ishida, Kentaro
    Amaya, Naoki
    Uzui, Hiroyasu
    Tada, Hiroshi
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2018, 53 (03) : 301 - 308