摘要
This study evaluates in vivo methods for calculating cortical thickness (Ct.Th) with respect to sensitivity to tissue-level changes in mineralization and the ability to predict whole-bone mechanical properties. Distal radial and tibial images obtained from normal volunteers using high-resolution peripheral quantitative computed tomography (HR-pQCT) were segmented using three thresholds including the manufacturer default and ±5% in terms of equivalent mineral density. Ct.Th was determined in two ways: using a direct three-dimensional (3D) method and using an annular method, where cortical bone volume is divided by periosteal surface area. Dcomp (mg HA/cm3) was calculated based on the mean density-calibrated linear attenuation values of the cortical compartment. Finite element analysis was performed to evaluate the predictive ability of the annular and direct Ct.Th methods. Using the direct 3D method, a ±5% change in threshold resulted in a 2% mean difference in Ct.Th for both the radius and tibia. An average difference of 5% was found using the annular method. The change in threshold produced changes in Dcomp ranging 0.50-1.56% for both the tibia and radius. Annular Ct.Th correlated more strongly with whole-bone apparent modulus (R2 = 0.64 vs. R2 = 0.41). Both thickness calculation methods and threshold selection have a direct impact on cortical parameters derived from HR-pQCT images. Indirectly, these results suggest that moderate changes in tissue-level mineralization can affect cortical measures. Furthermore, while the direct 3D Ct.Th method is less sensitive to threshold effects, both methods are moderate predictors of mechanical strength, with the annular method being the stronger correlate.
引用
收藏
页码:364 / 371
页数:7
相关论文
共 50 条
  • [31] Differential effects of menopause and metabolic disease on trabecular and cortical bone assessed by peripheral quantitative computed tomography (pQCT)
    Tsurusaki, K
    Ito, M
    Hayashi, K
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (865): : 14 - 22
  • [32] The effects of multiple high-resolution peripheral quantitative computed tomography scans on bone healing in a rabbit radial bone defect model
    Beck, Aswin
    Woods, Shane
    Lansdowne, Jennifer L.
    Arens, Daniel
    [J]. BONE, 2013, 56 (02) : 312 - 319
  • [33] Meta-analysis of Diabetes Mellitus-Associated Differences in Bone Structure Assessed by High-Resolution Peripheral Quantitative Computed Tomography
    Walle, Matthias
    Whittier, Danielle E.
    Frost, Morten
    Mueller, Ralph
    Collins, Caitlyn J.
    [J]. CURRENT OSTEOPOROSIS REPORTS, 2022, 20 (6) : 398 - 409
  • [34] Impaired bone microarchitecture in distal interphalangeal joints in patients with primary hypertrophic osteoarthropathy assessed by high-resolution peripheral quantitative computed tomography
    Pang, Q.
    Xu, Y.
    Qi, X.
    Huang, L.
    Hung, V. W.
    Xu, J.
    Liao, R.
    Hou, Y.
    Jiang, Y.
    Yu, W.
    Wang, O.
    Li, M.
    Xing, X.
    Xia, W.
    Qin, L.
    [J]. OSTEOPOROSIS INTERNATIONAL, 2020, 31 (01) : 153 - 164
  • [35] Impaired bone microarchitecture in distal interphalangeal joints in patients with primary hypertrophic osteoarthropathy assessed by high-resolution peripheral quantitative computed tomography
    Q. Pang
    Y. Xu
    X. Qi
    L. Huang
    V.W. Hung
    J. Xu
    R. Liao
    Y. Hou
    Y. Jiang
    W. Yu
    O. Wang
    M. Li
    X. Xing
    W. Xia
    L. Qin
    [J]. Osteoporosis International, 2020, 31 : 153 - 164
  • [36] Meta-analysis of Diabetes Mellitus-Associated Differences in Bone Structure Assessed by High-Resolution Peripheral Quantitative Computed Tomography
    Matthias Walle
    Danielle E. Whittier
    Morten Frost
    Ralph Müller
    Caitlyn J. Collins
    [J]. Current Osteoporosis Reports, 2022, 20 : 398 - 409
  • [37] High-resolution peripheral quantitative computed tomography in children with osteogenesis imperfecta
    David J. Fennimore
    Maria Digby
    Margaret Paggiosi
    Paul Arundel
    Nick J. Bishop
    Paul Dimitri
    Amaka C. Offiah
    [J]. Pediatric Radiology, 2020, 50 : 1781 - 1787
  • [38] High-resolution peripheral quantitative computed tomography in children with osteogenesis imperfecta
    Fennimore, David J.
    Digby, Maria
    Paggiosi, Margaret
    Arundel, Paul
    Bishop, Nick J.
    Dimitri, Paul
    Offiah, Amaka C.
    [J]. PEDIATRIC RADIOLOGY, 2020, 50 (12) : 1781 - 1787
  • [39] High-resolution peripheral quantitative computed tomography: research or clinical practice?
    Gazzotti, Silvia
    Aparisi Gomez, Maria Pilar
    Schileo, Enrico
    Taddei, Fulvia
    Sangiorgi, Luca
    Fusaro, Maria
    Miceli, Marco
    Guglielmi, Giuseppe
    Bazzocchi, Alberto
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2023, 96 (1150):
  • [40] The effect of voxel size on high-resolution peripheral computed tomography measurements of trabecular and cortical bone microstructure
    Tjong, Willy
    Kazakia, Galateia J.
    Burghardt, Andrew J.
    Majumdar, Sharmila
    [J]. MEDICAL PHYSICS, 2012, 39 (04) : 1893 - 1903