The effect of voxel size on high-resolution peripheral computed tomography measurements of trabecular and cortical bone microstructure

被引:83
|
作者
Tjong, Willy [1 ]
Kazakia, Galateia J. [1 ]
Burghardt, Andrew J. [1 ]
Majumdar, Sharmila [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, Musculoskeletal Quantitat Imaging Res Grp, San Francisco, CA 94107 USA
关键词
HR-pQCT; micro-CT; resolution; trabecular bone; cortical bone; DISTAL RADIUS; POSTMENOPAUSAL WOMEN; POROSITY; DENSITY; MICROARCHITECTURE; THICKNESS; ACCURACY; PLATES; TIBIA;
D O I
10.1118/1.3689813
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Accurate quantification of bone microstructure plays a significant role in understanding bone mechanics and response to disease or treatment. High-resolution peripheral quantitative computed tomography (HR-pQCT) allows for the quantification of trabecular and cortical structure in vivo, with the capability of generating images at multiple voxel sizes (41, 82, and 123 mu m). The aim of this study was to characterize the effect of voxel size on structural measures of trabecular and cortical bone and to determine accuracy in reference to micro-CT (mCT), the gold standard for bone microstructure quantification. Methods: Seventeen radii from human cadaver specimens were imaged at each HR-pQCT voxel size and subsequently imaged using mu CT. Bone density and microstructural assessment was performed in both the trabecular and cortical compartments, including cortical porosity quantification. Two distinct analysis techniques were applied to the 41 mu m HR-pQCT data: the standard clinical indirect analysis and a direct analysis requiring no density or structural model assumptions. Analysis parameters were adjusted to enable segmentation and structure extraction at each voxel size. Results: For trabecular microstructural measures, the 41 mu m HR-pQCT data displayed the strongest correlations and smallest errors compared to mu CT data. The direct analysis technique applied to the 41 mu m data yielded an additional improvement in accuracy, especially for measures of trabecular thickness. The 123 mu m data performed poorly, with all microstructural measures either having moderate or nonsignificant correlations with mu CT data. Trabecular densitometric measures showed strong correlations to mu CT data across all voxel sizes. Cortical thickness was strongly correlated with mu CT values across all HR-pQCT voxel sizes. The accuracy of cortical porosity parameters was highly dependent on voxel size; again, the 41 mu m data was most strongly correlated. Measures of cortical density and pore diameter at all HR-pQCT voxel sizes had either weak or nonsignificant correlations. Conclusions: This study demonstrates the effect of voxel size on the accuracy of HR-pQCT measurements of trabecular and cortical microstructure and presents parameters for HR-pQCT analysis at nonstandard resolutions. For all parameters measured, correlations were strongest at 41 mu m. Weak correlations for porosity measures indicate that a better understanding of pore structure and resolution dependence is needed. (C) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.3689813]
引用
收藏
页码:1893 / 1903
页数:11
相关论文
共 50 条
  • [1] Acromegaly Has a Negative Influence on Trabecular Bone, But Not on Cortical Bone, as Assessed by High-Resolution Peripheral Quantitative Computed Tomography
    Madeira, Miguel
    Neto, Leonardo Vieira
    Paranhos Neto, Francisco de Paula
    Barbosa Lima, Inaya Correa
    Carvalho de Mendonca, Laura Maria
    Gadelha, Monica Roberto
    Fleiuss de Farias, Maria Lucia
    [J]. JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2013, 98 (04): : 1734 - 1741
  • [2] Multicenter precision of cortical and trabecular bone quality measures assessed by high-resolution peripheral quantitative computed tomography
    Burghardt, Andrew J.
    Pialat, Jean-Baptiste
    Kazakia, Galateia J.
    Boutroy, Stephanie
    Engelke, Klaus
    Patsch, Janina M.
    Valentinitsch, Alexander
    Liu, Danmei
    Szabo, Eva
    Bogado, Cesar E.
    Belen Zanchetta, Maria
    McKay, Heather A.
    Shane, Elizabeth
    Boyd, Steven K.
    Bouxsein, Mary L.
    Chapurlat, Roland
    Khosla, Sundeep
    Majumdar, Sharmila
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 2013, 28 (03) : 524 - 536
  • [3] Assessment of trabecular and cortical architecture and mechanical competence of bone by high-resolution peripheral computed tomography: comparison with transiliac bone biopsy
    Cohen, A.
    Dempster, D. W.
    Mueller, R.
    Guo, X. E.
    Nickolas, T. L.
    Liu, X. S.
    Zhang, X. H.
    Wirth, A. J.
    van Lenthe, G. H.
    Kohler, T.
    McMahon, D. J.
    Zhou, H.
    Rubin, M. R.
    Bilezikian, J. P.
    Lappe, J. M.
    Recker, R. R.
    Shane, E.
    [J]. OSTEOPOROSIS INTERNATIONAL, 2010, 21 (02) : 263 - 273
  • [4] Assessment of trabecular and cortical architecture and mechanical competence of bone by high-resolution peripheral computed tomography: comparison with transiliac bone biopsy
    A. Cohen
    D. W. Dempster
    R. Müller
    X. E. Guo
    T. L. Nickolas
    X. S. Liu
    X. H. Zhang
    A. J. Wirth
    G. H. van Lenthe
    T. Kohler
    D. J. McMahon
    H. Zhou
    M. R. Rubin
    J. P. Bilezikian
    J. M. Lappe
    R. R. Recker
    E. Shane
    [J]. Osteoporosis International, 2010, 21 : 263 - 273
  • [5] In vivo assessment of trabecular bone microarchitecture by high-resolution peripheral quantitative computed tomography
    Boutroy, S
    Bouxsein, ML
    Munoz, F
    Delmas, PD
    [J]. JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2005, 90 (12): : 6508 - 6515
  • [6] Accuracy of cortical and trabecular bone measurements with peripheral quantitative computed tomography (pQCT)
    Augat, P
    Gordon, CL
    Lang, TF
    Iida, H
    Genant, HK
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (10): : 2873 - 2883
  • [7] Temporal bone measurements on high-resolution computed tomography
    Ekinci, G
    Koç, A
    Baltacioglu, F
    Veyseller, B
    Altintas, O
    Han, T
    [J]. JOURNAL OF OTOLARYNGOLOGY, 2004, 33 (06): : 387 - 389
  • [8] High-resolution Quantitative Computed Tomography Demonstrates Structural Defects in Cortical and Trabecular Bone in IBD Patients
    Haschka, Judith
    Hirschmann, Simon
    Kleyer, Arnd
    Englbrecht, Matthias
    Faustini, Francesca
    Simon, David
    Figueiredo, Camille P.
    Schuster, Louis
    Muschitz, Christian
    Kocijan, Roland
    Resch, Heinrich
    Atreya, Raja
    Rech, Juergen
    Neurath, Markus F.
    Schett, Georg
    [J]. JOURNAL OF CROHNS & COLITIS, 2016, 10 (05): : 532 - 540
  • [9] Trabecular and cortical bone microarchitecture using high-resolution peripheral quantitative computed tomographic imaging in diabetic peripheral neuropathy
    Arjunan, Durairaj
    Rastogi, Ashu
    Ghosh, Jayaditya
    Mukherjee, Soham
    Singh, Raveena
    Dhiman, Vandana
    Bhadada, Sanjay K.
    [J]. DIABETES & METABOLIC SYNDROME-CLINICAL RESEARCH & REVIEWS, 2024, 18 (08)
  • [10] Correlation Between Cone-Beam Computed Tomography and High-Resolution Peripheral Computed Tomography for Assessment of Wrist Bone Microstructure
    Mys, Karen
    Varga, Peter
    Gueorguiev, Boyko
    Hemmatian, Haniyeh
    Stockmans, Filip
    van Lenthe, G. Harry
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 2019, 34 (05) : 867 - 874