WATTS happening? Evaluation of thermal dose during holmium laser lithotripsy in a high-fidelity anatomic model

被引:2
|
作者
Wanderling, Christopher [1 ]
Saxton, Aaron [1 ]
Phan, Dennis [1 ]
Doersch, Karen [1 ]
Shepard, Lauren [1 ,2 ]
Schuler, Nathan [1 ,2 ]
Osinski, Thomas [1 ]
Quarrier, Scott [1 ]
Ghazi, Ahmed [1 ,2 ]
机构
[1] Univ Rochester, Dept Urol, Med Ctr, Rochester, NY 14627 USA
[2] Johns Hopkins Univ, Dept Urol, Baltimore, MD USA
关键词
Thermal dose; Temperature; Laser lithotripsy; Holmium; Anatomic model; POWER; URETEROSCOPY;
D O I
10.1007/s00345-024-04821-9
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
PurposeTo evaluate the thermal profiles of the holmium laser at different laser parameters at different locations in an in vitro anatomic pelvicalyceal collecting system (PCS) model. Laser lithotripsy is the cornerstone of treatment for urolithiasis. With the prevalence of high-powered lasers, stone ablation efficiency has become more pronounced. Patient safety remains paramount during surgery. It is well recognized that the heat generated from laser lithotripsy has the potential to cause thermal tissue damage.MethodsUtilizing high-fidelity, 3D printed hydrogel models of a PCS with a synthetic BegoStone implanted in the renal pelvis, laser lithotripsy was performed with the Moses 2.0 holmium laser. At a standard power (40 W) and irrigation pressure (100 cm H2O), we evaluated operator duty cycle (ODC) variations with different time-on intervals at four different laser settings. Temperature was measured at two separate locations-at the stone and away from the stone.ResultsTemperatures were highest closest to the laser tip with a decrease away from the laser. Fluid temperatures increased with longer laser-on times and higher ODCs. Thermal doses were greater with increased ODCs and the threshold for thermal injury was reached for ODCs of 75% and 100%.ConclusionTemperature generation and thermal dose delivered are greatest closer to the tip of the laser fiber and are not dependent on power alone. Significant temperature differences were noted between four laser settings at a standardized power (40 W). Temperatures can be influenced by a variety of factors, such as laser-on time, operator duty cycle, and location in the PCS.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] COMPARISON OF LASER OPERATOR DUTY CYCLES (ODC) DURING HIGH POWER HOLMIUM:YAG (HO:YAG) VERSUS THULIUM FIBER LASER (TFL) LITHOTRIPSY
    Ghazi, Ahmed
    Khalil, Mahmoud
    Jain, Rajat
    Quarrier, Scott
    JOURNAL OF UROLOGY, 2021, 206 : E94 - E95
  • [42] A randomized evaluation of simulation training on performance of vascular anastomosis on a high-fidelity in vivo model: The role of deliberate practice
    Price, Joel
    Naik, Viren
    Boodhwani, Munir
    Brandys, Tim
    Hendry, Paul
    Lam, Buu-Khanh
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2011, 142 (03): : 496 - 503
  • [43] Reassessing the accumulated copying error model with an eye toward detecting high-fidelity cultural transmission during the Paleolithic
    Premo, L. S.
    AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 2020, 171 : 222 - 222
  • [44] A prospective evaluation of high- and low-power holmium laser settings for transurethral lithotripsy in the management of adults with large bladder calculi
    Bhat, Abhishek
    Katz, Jonathan E.
    Banerjee, Indraneel
    Blachman-Braun, Ruben
    Alter, Kevin
    Shah, Rashmi H.
    Smith, Nicholas Anthony
    Shah, Hemendra N.
    WORLD JOURNAL OF UROLOGY, 2021, 39 (09) : 3481 - 3488
  • [45] A prospective evaluation of high- and low-power holmium laser settings for transurethral lithotripsy in the management of adults with large bladder calculi
    Abhishek Bhat
    Jonathan E. Katz
    Indraneel Banerjee
    Ruben Blachman-Braun
    Kevin Alter
    Rashmi H. Shah
    Nicholas Anthony Smith
    Hemendra N. Shah
    World Journal of Urology, 2021, 39 : 3481 - 3488
  • [46] Temperature changes of renal calyx during high-power flexible ureteroscopic Moses holmium laser lithotripsy: a case analysis study
    Zhiyue Wu
    Jingchao Wei
    Chengfang Sun
    Qi Huangfu
    Bohan Wang
    Guangyi Huang
    Kai Qi
    Zeping Jiang
    Wuan Zhu
    Jiaming Wen
    International Urology and Nephrology, 2023, 55 : 1685 - 1692
  • [47] Automatic Generation of a High-Fidelity Dynamic Thermal-Hydraulic Process Simulation Model From a 3D Plant Model
    Martinez, Gerardo Santillan
    Sierla, Seppo A.
    Karhela, Tommi A.
    Lappalainen, Jari
    Vyatkin, Valeriy
    IEEE ACCESS, 2018, 6 : 45217 - 45232
  • [48] Kidney Stone Ablation Times and Peak Saline Temperatures During Holmium: YAG and Thulium Fiber Laser Lithotripsy, In Vitro, in a Ureteral Model
    Hardy, Luke A.
    Wilson, Christopher R.
    Irby, Pierce B.
    Fried, Nathaniel M.
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS XI, 2015, 9303
  • [49] Temperature changes of renal calyx during high-power flexible ureteroscopic Moses holmium laser lithotripsy: a case analysis study
    Wu, Zhiyue
    Wei, Jingchao
    Sun, Chengfang
    Qi, Huangfu
    Wang, Bohan
    Huang, Guangyi
    Qi, Kai
    Jiang, Zeping
    Zhu, Wuan
    Wen, Jiaming
    INTERNATIONAL UROLOGY AND NEPHROLOGY, 2023, 55 (07) : 1685 - 1692
  • [50] The development, implementation, and evaluation of a medical student peer teaching training curriculum during a high-fidelity prehospital trauma simulation
    Rudinsky, Sherri L.
    Spalding, Carmen
    Conley, Sean P.
    Everett, Lauren
    Cole, Rebekah
    AEM EDUCATION AND TRAINING, 2022, 6 (04)