WATTS happening? Evaluation of thermal dose during holmium laser lithotripsy in a high-fidelity anatomic model

被引:2
|
作者
Wanderling, Christopher [1 ]
Saxton, Aaron [1 ]
Phan, Dennis [1 ]
Doersch, Karen [1 ]
Shepard, Lauren [1 ,2 ]
Schuler, Nathan [1 ,2 ]
Osinski, Thomas [1 ]
Quarrier, Scott [1 ]
Ghazi, Ahmed [1 ,2 ]
机构
[1] Univ Rochester, Dept Urol, Med Ctr, Rochester, NY 14627 USA
[2] Johns Hopkins Univ, Dept Urol, Baltimore, MD USA
关键词
Thermal dose; Temperature; Laser lithotripsy; Holmium; Anatomic model; POWER; URETEROSCOPY;
D O I
10.1007/s00345-024-04821-9
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
PurposeTo evaluate the thermal profiles of the holmium laser at different laser parameters at different locations in an in vitro anatomic pelvicalyceal collecting system (PCS) model. Laser lithotripsy is the cornerstone of treatment for urolithiasis. With the prevalence of high-powered lasers, stone ablation efficiency has become more pronounced. Patient safety remains paramount during surgery. It is well recognized that the heat generated from laser lithotripsy has the potential to cause thermal tissue damage.MethodsUtilizing high-fidelity, 3D printed hydrogel models of a PCS with a synthetic BegoStone implanted in the renal pelvis, laser lithotripsy was performed with the Moses 2.0 holmium laser. At a standard power (40 W) and irrigation pressure (100 cm H2O), we evaluated operator duty cycle (ODC) variations with different time-on intervals at four different laser settings. Temperature was measured at two separate locations-at the stone and away from the stone.ResultsTemperatures were highest closest to the laser tip with a decrease away from the laser. Fluid temperatures increased with longer laser-on times and higher ODCs. Thermal doses were greater with increased ODCs and the threshold for thermal injury was reached for ODCs of 75% and 100%.ConclusionTemperature generation and thermal dose delivered are greatest closer to the tip of the laser fiber and are not dependent on power alone. Significant temperature differences were noted between four laser settings at a standardized power (40 W). Temperatures can be influenced by a variety of factors, such as laser-on time, operator duty cycle, and location in the PCS.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] EFFECT OF PELVICALYCEAL FLUID VOLUME ON TEMPERATURE ELEVATION AND THERMAL DOSE DURING LASER LITHOTRIPSY
    Khajeh, Nikta R.
    Hall, Timothy L.
    Ghani, Khurshid R.
    Roberts, William W.
    JOURNAL OF UROLOGY, 2021, 206 : E682 - E683
  • [22] Editorial Comment on: Thermal Response to High-Power Holmium Laser Lithotripsy by Aldoukhi et al.
    Gross, Andreas J.
    Netsch, Christopher
    JOURNAL OF ENDOUROLOGY, 2017, 31 (12) : 1313 - 1313
  • [23] Evaluation of high-fidelity simulation training in radiation oncology using an outcomes logic model
    Giuliani, Meredith
    Gillan, Caitlin
    Wong, Olive
    Harnett, Nicole
    Milne, Emily
    Moseley, Doug
    Thompson, Robert
    Catton, Pamela
    Bissonnette, Jean-Pierre
    RADIATION ONCOLOGY, 2014, 9
  • [24] Evaluation of high-fidelity simulation training in radiation oncology using an outcomes logic model
    Meredith Giuliani
    Caitlin Gillan
    Olive Wong
    Nicole Harnett
    Emily Milne
    Doug Moseley
    Robert Thompson
    Pamela Catton
    Jean-Pierre Bissonnette
    Radiation Oncology, 9
  • [25] Development and evaluation of a high-fidelity lactation simulation model for health professional breastfeeding education
    Sadovnikova, Anna
    Chuisano, Samantha A.
    Ma, Kaoer
    Grabowski, Aria
    Stanley, Kate P.
    Mitchell, Katrina B.
    Eglash, Anne
    Plott, Jeffrey S.
    Zielinski, Ruth E.
    Anderson, Olivia S.
    INTERNATIONAL BREASTFEEDING JOURNAL, 2020, 15 (01)
  • [26] Development and evaluation of a high-fidelity lactation simulation model for health professional breastfeeding education
    Anna Sadovnikova
    Samantha A. Chuisano
    Kaoer Ma
    Aria Grabowski
    Kate P. Stanley
    Katrina B. Mitchell
    Anne Eglash
    Jeffrey S. Plott
    Ruth E. Zielinski
    Olivia S. Anderson
    International Breastfeeding Journal, 15
  • [27] High-fidelity modelling of selective laser melting copper alloy: Laser reflection behavior and thermal-fluid dynamics
    Ren, Zhihao
    Zhang, David Z.
    Fu, Guang
    Jiang, Junjie
    Zhao, Miao
    MATERIALS & DESIGN, 2021, 207 (207)
  • [28] A spatiotemporal two-level method for high-fidelity thermal analysis of laser powder bed fusion
    Viguerie, Alex
    Carraturo, Massimo
    Reali, Alessandro
    Auricchio, Ferdinando
    FINITE ELEMENTS IN ANALYSIS AND DESIGN, 2022, 210
  • [29] Development of a Model Predictive Airpath Controller for a Diesel Engine on a High-Fidelity Engine Model with Transient Thermal Dynamics
    Zhang, Jiadi
    Amini, Mohammad Reza
    Kolmanovsky, Ilya
    Tsutsumi, Munechika
    Nakada, Hayato
    2022 AMERICAN CONTROL CONFERENCE, ACC, 2022, : 3058 - 3063
  • [30] Patterns of Laser Activation During Ureteroscopic Lithotripsy: Effects on Caliceal Fluid Temperature and Thermal Dose
    Aldoukhi, Ali H.
    Dau, Julie J.
    Majdalany, Sami E.
    Hall, Timothy L.
    Ghani, Khurshid R.
    Hollingsworth, John M.
    Ambani, Sapan N.
    Dauw, Casey A.
    Roberts, William W.
    JOURNAL OF ENDOUROLOGY, 2021, 35 (08) : 1217 - 1222