Partial discharge localisation in transformers using UHF technique: non-iterative method

被引:0
|
作者
Antony D. [1 ]
Mishra P. [1 ]
Todi A. [1 ]
John N.A. [1 ]
Patankar A.M. [1 ]
机构
[1] Department of Electrical Engineering, Ramaiah University of Applied Sciences, Bengaluru
关键词
Dielectrics; Electromagnetic (EM) waves; Insulation; Partial discharge (PD); Time difference of arrival (TDOA); Ultra High Frequency (UHF);
D O I
10.1007/s41870-020-00481-1
中图分类号
学科分类号
摘要
The mathematical model of the Partial Discharge (PD) location detection system in transformers, using the Ultra High Frequency (UHF) technique, is a system of non-linear sphere equations. These non-linear equations are solved to determine the PD source co-ordinates. In this paper, a non-iterative method is studied to determine the PD location. For the study, a simulation-based system is modelled in an EM-solver. The UHF technique-based detection of the PD source location needs a minimum of four sensors. The non-iterative algorithm’s significant drawback is that it provides two solutions. However, in the present study, five sensors are positioned at specified coordinates to attain the real PD position (from the two obtained solutions) with higher accuracy. © 2020, Bharati Vidyapeeth's Institute of Computer Applications and Management.
引用
收藏
页码:291 / 297
页数:6
相关论文
共 50 条
  • [1] A non-iterative partial discharge source location method for transformers employing acoustic emission techniques
    Kundu, Prasanta
    Kishore, N. K.
    Sinha, A. K.
    APPLIED ACOUSTICS, 2009, 70 (11-12) : 1378 - 1383
  • [2] Partial Discharge Localization in Transformers Using UHF Detection Method
    Sinaga, H. H.
    Phung, B. T.
    Blackburn, T. R.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2012, 19 (06) : 1891 - 1900
  • [3] Partial Discharge Localization in Transformers Using UHF Sensors
    Sinaga, H. H.
    Phung, B. T.
    Ao, P. L.
    Blackburn, T. R.
    2011 ELECTRICAL INSULATION CONFERENCE (EIC), 2011, : 64 - 68
  • [4] Enhancing the Accuracy of Partial Discharge Localization in Power Transformers Using the UHF Measurement Technique
    Azirani, Mohammad Akbari
    Ariannik, Mohamadreza
    Werle, Peter
    Akbari, Asghar
    2019 IEEE ELECTRICAL INSULATION CONFERENCE (EIC), 2019, : 58 - 62
  • [5] On the UHF partial discharge measurement in transformers
    Kuppuswamy, R
    2003 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2003, : 349 - 352
  • [6] Application of UHF Method for Partial Discharge Source Location in Power Transformers
    Dukanac, Djordje
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2018, 25 (06) : 2266 - 2278
  • [7] UHF Sensor Array for Partial Discharge Location in Transformers
    Sinaga, H. H.
    Phung, B. T.
    Blackburn, T. R.
    PROCEEDINGS OF 2012 IEEE INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (IEEE CMD 2012), 2012, : 979 - 982
  • [8] Study on the monitoring technique of partial discharge of GIS by UHF method
    2005, Xi'an High Voltage Apparatus Research Institute, Beijing, China (41):
  • [9] Localisation of Partial Discharge source through Delay calculation using UHF sensors
    Anitha, Bhukya
    Mishra, Dipak Kumar
    Koley, Chiranjib
    2017 IEEE INTERNATIONAL WIE CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING (IEEE WIECON-ECE 2017), 2017, : 172 - 175
  • [10] Partial discharge measurements on power transformers using transfer function for detection and localisation
    Werle, P
    Gockenbach, E
    Borsi, H
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2003, : 1154 - 1157