The prediction of polyethylene wear rate and debris morphology produced by microscopic asperities on femoral heads

被引:0
|
作者
C. M. Mcnie
D. C. Barton
E. Ingham
J. L. Tipper
J. Fisher
M. H. Stone
机构
[1] The University of Leeds,School of Mechanical Engineering and *Department of Microbiology
[2] Leeds General Infirmary,Department of Orthopaedic Surgery
关键词
Femoral Head; Wear Rate; UHMWPE; Wear Debris; Wear Factor;
D O I
暂无
中图分类号
学科分类号
摘要
Counterface damage in the form of scratches, caused by bone cement, bone or metallic particles, has been cited as a cause of increased wear of ultra-high molecular weight polyethylene (UHMWPE) acetabular cups. It is known that high levels of particulate wear debris lead to osteolysis. Surface damage was characterized in a series of explanted Charnley femoral heads. The heads had a mean scratch height of 1 μm with a mean aspect ratio (defined as height divided by half width) of 0.1. Wear discs were artificially scratched using these scratch geometries as a guide. In addition, the scratch geometries were incorporated into a finite element model of a stainless steel asperity repeatedly sliding over UHMWPE under conditions similar to those in an artificial hip joint. Wear tests showed a strong correlation between the average cross-sectional area of the scratch lip above the mean zero line and the measured wear factor. The finite element model predicted increases in the area of UHMWPE suffering plastic strain with increases in the cross-sectional area of the asperity above the mean line. Analysis of the wear debris showed the mode of the particle size was 0.01–0.5 μm for all cases. The morphology of the particles varied with aspect ratio of the asperity, with an increased percentage mass of submicrometer-sized debris with increased scratch lip aspect ratio. The finite element results predicted that the maximum surface strains would increase with increasing asperity aspect ratio. Examination of the worn UHMWPE pin surfaces showed an association between increased surface damage, probably due to high surface strains, and increased aspect ratio. The large areas of surface plastic strain predicted for asperities with high cross-sectional areas above the mean line offer an explanation for the positive correlation between wear rate and the average cross-sectional area of the scratch lip material. The higher surface strains predicted for the higher aspect ratios may explain the increased percentage mass of biologically active submicrometer-sized wear particles found for scratch lips with higher aspect ratios. ©©2000 Kluwer Academic Publishers
引用
收藏
页码:163 / 174
页数:11
相关论文
共 50 条
  • [41] Comparison of wear of ultra-high molecular weight polyethylene acetabular cups against surface-engineered femoral heads
    Galvin, A.
    Brockett, C.
    Williams, S.
    Hatto, P.
    Burton, A.
    Isaac, G.
    Stone, M.
    Ingham, E.
    Fisher, J.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2008, 222 (H7) : 1073 - 1080
  • [42] Long-term polyethylene wear rates and clinical outcomes of oxidized zirconium femoral heads on highly cross-linked polyethylene in total hip arthroplasty
    Buckner, Brandt C.
    Urban, Nathanael D.
    Cahoy, Kevin M.
    Lyden, Elizabeth R.
    Deans, Christopher F.
    Garvin, Kevin L.
    BONE & JOINT JOURNAL, 2024, 106B (03): : 38 - 43
  • [43] Comparison of the wear rates of twenty-eight and thirty-two-millimeter femoral heads on cross-linked polyethylene acetabular cups in a wear simulator
    Hermida, JC
    Bergula, A
    Chen, P
    Colwell, CW
    D'Lima, DD
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (12): : 2325 - 2331
  • [44] Comparison of in Vivo Characteristics of Polyethylene Wear Particles Produced by a Metal and a Ceramic Femoral Component in Total Knee Replacement
    Veigl, D.
    Vavrik, P.
    Pokorny, D.
    Slouf, M.
    Pavlova, E.
    Landor, I.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2011, 78 (01) : 49 - 55
  • [45] Migration of polyethylene wear debris in one type of uncemented femoral component with circumferential porous coating - An autopsy study of 5 femurs
    von Knoch, M
    Engh, CA
    Sychterz, CJ
    Engh, CA
    Willert, HG
    JOURNAL OF ARTHROPLASTY, 2000, 15 (01): : 72 - 78
  • [46] ASEPTIC LOOSENING IN TOTAL HIP-ARTHROPLASTY SECONDARY TO OSTEOLYSIS INDUCED BY WEAR DEBRIS FROM TITANIUM-ALLOY MODULAR FEMORAL HEADS
    LOMBARDI, AV
    MALLORY, TH
    VAUGHN, BK
    DROUILLARD, P
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1989, 71A (09): : 1337 - 1342
  • [47] Characterization of wear debris released from alumina-on-alumina hip prostheses: Analysis of retrieved femoral heads and pen-prosthetic tissues
    Rony, Louis
    de Sainte Hermine, Pierre
    Steiger, Vincent
    Mallet, Romain
    Hubert, Laurent
    Chappard, Daniel
    MICRON, 2018, 104 : 89 - 94
  • [48] WEAR OF POLYETHYLENE ACETABULAR CUPS AGAINST ALUMINA FEMORAL HEADS - 5 PROSTHESES COMPARED IN A HIP SIMULATOR FOR 35 MILLION WALKING CYCLES
    SAIKKO, VO
    ACTA ORTHOPAEDICA SCANDINAVICA, 1993, 64 (05): : 507 - 512
  • [49] Wear resistance of artificial hip joints with poly(2-methacryloyloxyethyl phosphorylcholine) grafted polyethylene: Comparisons with the effect of polyethylene cross-linking and ceramic femoral heads
    Moro, Toru
    Kawaguchi, Hiroshi
    Ishihara, Kazuhiko
    Kyomoto, Masayuki
    Karita, Tatsuro
    Ito, Hideya
    Nakamura, Kozo
    Takatori, Yoshio
    BIOMATERIALS, 2009, 30 (16) : 2995 - 3001
  • [50] Measurement of early wear rates with X3 polyethylene and 36-mm femoral heads in young patients - a prospective study
    Selvarajah, Elango
    Hooper, Gary J.
    Woodfield, Timothy B. F.
    Inglis, Grahame
    Frampton, Christopher
    CURRENT ORTHOPAEDIC PRACTICE, 2013, 24 (06): : 641 - 646