The prediction of polyethylene wear rate and debris morphology produced by microscopic asperities on femoral heads

被引:0
|
作者
C. M. Mcnie
D. C. Barton
E. Ingham
J. L. Tipper
J. Fisher
M. H. Stone
机构
[1] The University of Leeds,School of Mechanical Engineering and *Department of Microbiology
[2] Leeds General Infirmary,Department of Orthopaedic Surgery
关键词
Femoral Head; Wear Rate; UHMWPE; Wear Debris; Wear Factor;
D O I
暂无
中图分类号
学科分类号
摘要
Counterface damage in the form of scratches, caused by bone cement, bone or metallic particles, has been cited as a cause of increased wear of ultra-high molecular weight polyethylene (UHMWPE) acetabular cups. It is known that high levels of particulate wear debris lead to osteolysis. Surface damage was characterized in a series of explanted Charnley femoral heads. The heads had a mean scratch height of 1 μm with a mean aspect ratio (defined as height divided by half width) of 0.1. Wear discs were artificially scratched using these scratch geometries as a guide. In addition, the scratch geometries were incorporated into a finite element model of a stainless steel asperity repeatedly sliding over UHMWPE under conditions similar to those in an artificial hip joint. Wear tests showed a strong correlation between the average cross-sectional area of the scratch lip above the mean zero line and the measured wear factor. The finite element model predicted increases in the area of UHMWPE suffering plastic strain with increases in the cross-sectional area of the asperity above the mean line. Analysis of the wear debris showed the mode of the particle size was 0.01–0.5 μm for all cases. The morphology of the particles varied with aspect ratio of the asperity, with an increased percentage mass of submicrometer-sized debris with increased scratch lip aspect ratio. The finite element results predicted that the maximum surface strains would increase with increasing asperity aspect ratio. Examination of the worn UHMWPE pin surfaces showed an association between increased surface damage, probably due to high surface strains, and increased aspect ratio. The large areas of surface plastic strain predicted for asperities with high cross-sectional areas above the mean line offer an explanation for the positive correlation between wear rate and the average cross-sectional area of the scratch lip material. The higher surface strains predicted for the higher aspect ratios may explain the increased percentage mass of biologically active submicrometer-sized wear particles found for scratch lips with higher aspect ratios. ©©2000 Kluwer Academic Publishers
引用
收藏
页码:163 / 174
页数:11
相关论文
共 50 条
  • [31] WEAR OF POLYETHYLENE ACETABULAR CUPS AGAINST ZIRCONIA FEMORAL HEADS STUDIED WITH A HIP-JOINT SIMULATOR
    SAIKKO, V
    WEAR, 1994, 176 (02) : 207 - 212
  • [32] Comparison of in vivo wear between polyethylene liners articulating with ceramic and cobalt-chrome femoral heads
    Sychterz, CJ
    Engh, CA
    Young, AM
    Hopper, RH
    Engh, CA
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2000, 82B (07): : 948 - 951
  • [33] Do Oxidized Zirconium Femoral Heads Reduce Polyethylene Wear in Cemented THAs? A Blinded Randomized Clinical Trial
    Zaoui, Amine
    El Hage, Samer
    Langlois, Jean
    Scemama, Caroline
    Courpied, Jean Pierre
    Hamadouche, Moussa
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2015, 473 (12) : 3822 - 3828
  • [34] Oxinium modular femoral heads do not reduce polyethylene wear in cemented total hip arthroplasty at five years
    Jonsson, B. A.
    Kadar, T.
    Havelin, L. I.
    Haugan, K.
    Espehaug, B.
    Indrekvam, K.
    Furnes, O.
    Hallan, G.
    BONE & JOINT JOURNAL, 2015, 97B (11): : 1463 - 1469
  • [35] Effect of alumina femoral heads on polyethylene wear in cemented total hip arthroplasty -: Old versus current alumina
    Tanaka, K
    Tamura, J
    Kawanabe, K
    Shimizu, M
    Nakamura, T
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2003, 85B (05): : 655 - 660
  • [36] The rate of wear of second-generation highly crosslinked polyethylene liners five years post-operatively does not increase if large femoral heads are used
    Callary, S. A.
    Field, J. R.
    Campbell, D. G.
    BONE & JOINT JOURNAL, 2016, 98B (12): : 1604 - 1610
  • [37] Editor's Spotlight/Take 5: Polyethylene Wear Increases in Liners Articulating With Scratched Oxidized Zirconium Femoral Heads
    Leopold, Seth S.
    Wright, Timothy M.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2018, 476 (02) : 179 - 181
  • [38] Transfer of metallic debris after in vitro ceramic-on-metal simulation: Wear and degradation in Biolox® Delta composite femoral heads
    Taddei, Paola
    Ruggiero, Alessandro
    Pavoni, Eleonora
    Affatato, Saverio
    COMPOSITES PART B-ENGINEERING, 2017, 115 : 477 - 487
  • [39] High density polyethylene wear debris from a Charnley-Hastings bipolar hemiarthroplasty causing gross femoral osteolysis
    Sochart, DH
    Brewood, AFM
    JOURNAL OF ORTHOPAEDIC RHEUMATOLOGY, 1996, 9 (03): : 173 - 176
  • [40] The influence of lubricant on the morphology of ultra-high molecular weight polyethylene wear debris generated in laboratory tests
    Besong, AA
    Tipper, JL
    Mathews, BJ
    Ingham, E
    Stone, MH
    Fisher, J
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1999, 213 (H2) : 155 - 158