Investigation into the mechanism of bacterial adhesion to hydrogel-coated surfaces

被引:0
|
作者
R. Kunz
C. Anders
L. Heinrich
K. Gersonde
机构
[1] Creavis,
[2] Gesellschaft fu¨r Technologie und Innovation mbH,undefined
[3] Fraunhofer Institute for Biomedical Engineering,undefined
来源
Journal of Materials Science: Materials in Medicine | 1999年 / 10卷
关键词
Polymer; Contact Angle; Chain Length; Alkyl Group; Type Strain;
D O I
暂无
中图分类号
学科分类号
摘要
As a model for hydrogel-coated biomaterials, self-assembled monolayers of polyoxyethylene (POE) derivatives on sheets of polymeric biomaterials were prepared. The POE derivatives consisted of hydrophilic chains with different lengths and a long-chain alkyl group that served as an anchor function. The coatings obtained were analyzed with XPS and contact angle measurements showing hydrophilic chains of different lengths extending away from the surface. Bacterial adhesion was measured with a clinically relevant Klebsiella pneumoniae type strain and measurements reproduced 12 times. Bacterial adhesion decreased markedly with increasing hydrophilic chain length. Based upon these findings a new model for bacterial adhesion to hydrogel-coated surfaces is suggested: steric repulsion effects that increase with increasing chain length of grafted hydrophilic chains play an important role in bacterial adhesion to hydrogel-coated surfaces. © 1999 Kluwer Academic Publishers
引用
收藏
页码:649 / 652
页数:3
相关论文
共 50 条
  • [31] Facile Preparation of Hydrogel-Coated Surfaces with Antifouling and Salt Resistance for Efficient Solar-Driven Water Evaporation
    Zhang, Xingzhen
    Zhou, Shouyong
    Wang, Zhigang
    Wei, Xian
    Zhang, Shenxiang
    Jin, Jian
    ACS APPLIED MATERIALS & INTERFACES, 2023, 15 (43) : 50196 - 50205
  • [32] Correction to: Usefulness of Hydrogel-Coated Coils in Embolization of Pulmonary Arteriovenous Malformations
    Masashi Shimohira
    Tatsuya Kawai
    Takuya Hashizume
    Masahiro Muto
    Masanori Kitase
    Yuta Shibamoto
    CardioVascular and Interventional Radiology, 2018, 41 : 1140 - 1140
  • [33] Clinical efficacy of hydrogel-coated coils in embolization of pulmonary arteriovenous malformations
    Shimohira, M.
    Kawai, T.
    Hashizume, T.
    Nakagawa, M.
    Ozawa, Y.
    Shibamoto, Y.
    ANGIOGENESIS, 2018, 21 (01) : 162 - 162
  • [34] Immunocompatibility evaluation of hydrogel-coated polyimide implants for applications in regenerative medicine
    Sirova, Milada
    Van Vlierberghe, Sandra
    Matyasova, Veronika
    Rossmann, Pavel
    Schacht, Etienne
    Dubruel, Peter
    Rihova, Blanka
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2014, 102 (06) : 1982 - 1990
  • [35] Hydrogel-Coated Microelectrode Resists Protein Passivation of In Vivo Amperometric Sensors
    Yin, Yongyue
    Zeng, Hui
    Zhang, Shuai
    Gao, Nan
    Liu, Rantong
    Cheng, Shuwen
    Zhang, Meining
    ANALYTICAL CHEMISTRY, 2023, 95 (06) : 3390 - 3397
  • [36] Comments to “Usefulness of Hydrogel-Coated Coils in Embolization of Pulmonary Arteriovenous Malformations”
    Rengarajan Rajagopal
    Sanjiv Sharma
    CardioVascular and Interventional Radiology, 2018, 41 : 1807 - 1807
  • [37] Comments to "Usefulness of Hydrogel-Coated Coils in Embolization of Pulmonary Arteriovenous Malformations"
    Rajagopal, Rengarajan
    Sharma, Sanjiv
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2018, 41 (11) : 1807 - 1807
  • [38] Improving the reproducibility of hydrogel-coated glutamate microsensors by using an automated dipcoater
    Oldenziel, WH
    Beukema, W
    Westerink, BHC
    JOURNAL OF NEUROSCIENCE METHODS, 2004, 140 (1-2) : 117 - 126
  • [39] Treatment of Posttraumatic Aortic Pseudoaneurysms Using Detachable Hydrogel-Coated Coils
    Greben, Craig R.
    Axelrod, David J.
    Charles, Hearns
    Gandras, Eric J.
    Bank, Matthew
    Setton, Avi
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2009, 66 (06): : 1735 - 1738
  • [40] Hydrogel-Coated SERS Microneedles for Drug Monitoring in Dermal Interstitial Fluid
    Li, Yan
    Wang, Yunqing
    Mei, Rongchao
    Lv, Bingqian
    Zhao, Xizhen
    Bi, Liyan
    Xu, Hui
    Chen, Lingxin
    ACS SENSORS, 2024, 9 (05): : 2567 - 2574