Blood metal ion concentrations in metal-on-metal total hip arthroplasty

被引:4
|
作者
Ohtsuru T. [1 ]
Morita Y. [1 ]
Murata Y. [1 ]
Shimamoto S. [1 ]
Munakata Y. [1 ]
Kato Y. [2 ]
机构
[1] Department of Orthopedic Surgery, Tokyo Women’s Medical University, 8-1 Kawada-Cho, Shinjuku Ward, Tokyo
[2] Kita Shinagawa 3rd Hospital, 3-3-7 Kita-shinagawa, Shinagawa Ward, Tokyo
关键词
Angle; Cup version angle; Ions; Metal; Metal-on-metal; Total hip arthroplasty;
D O I
10.1007/s00590-017-1931-y
中图分类号
学科分类号
摘要
Introduction: The hip placement with a metal-on-metal (MOM) bearing has been used for both surface replacement and total hip arthroplasty (THA). Use of MOM bearing for hip replacement reduces the wear compared to conventional bearings. Methods: We prospectively assessed 30 patients who underwent unilateral MOM THA. A control group of 30 patients who underwent metal-on-polyethylene THA using the implants as the other group, except for bearing, were accessed. Blood samples were collected preoperatively and at 3- , 6- , 9- , 12- , 15- , 18- , and 24-month intervals. Changes in mean blood metal ion concentration were compared between the MOM and metal-on-polyethylene groups. Results: A statistically significant positive correlation was observed between blood cobalt and chromium concentrations in all of the patients. The mean blood ion concentrations of the MOM were significantly higher than those of the metal-on-polyethylene. A statistically significant negative correlation was found between maximum blood cobalt concentration and cup version angle. The maximum blood chromium concentrations in the patients who had larger cup version angles were more likely to decrease. Conclusions: We considered that cup version angle is one of the factors that have the greatest effect on blood metal ion concentration, and the target cup version angle that did not induce an increase in blood metal ion concentrations was approximately 20°. © 2017, Springer-Verlag France.
引用
收藏
页码:527 / 532
页数:5
相关论文
共 50 条
  • [21] Modes of Failure in Metal-on-Metal Total Hip Arthroplasty
    Fehring, Keith A.
    Fehring, Thomas K.
    [J]. ORTHOPEDIC CLINICS OF NORTH AMERICA, 2015, 46 (02) : 185 - +
  • [22] Pseudotumor in the Setting of Metal-on-Metal Total Hip Arthroplasty
    Sagoo, Navraj S.
    Sharma, Ruhi
    Johnson, Connor S.
    Stephenson, Kelly
    Aya, Kessiena L.
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2020, 12 (05)
  • [23] Management of failed metal-on-metal total hip arthroplasty
    Griffin, Justin W.
    D'Apuzzo, Michele
    Browne, James A.
    [J]. WORLD JOURNAL OF ORTHOPEDICS, 2012, 3 (06): : 70 - 74
  • [24] Is Metal-on-Metal Total Hip Arthroplasty Still an Alternative?
    Akisue, Toshihiro
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2017, 99 (18):
  • [25] Metal-on-metal articulation in total hip arthroplasty: update
    Srinivasan, Anand
    Levine, Brett R.
    Jacobs, Joshua J.
    [J]. CURRENT ORTHOPAEDIC PRACTICE, 2011, 22 (03): : 231 - 235
  • [26] Femoral offset found not to affect metal ion levels in metal-on-metal total hip arthroplasty
    Eoghan Pomeroy
    Fergal Macnamara
    Evelyn Murphy
    Niall McGoldrick
    Anant Mahapatra
    Nasir Awan
    [J]. Irish Journal of Medical Science (1971 -), 2019, 188 : 149 - 153
  • [27] Femoral offset found not to affect metal ion levels in metal-on-metal total hip arthroplasty
    Pomeroy, Eoghan
    Macnamara, Fergal
    Murphy, Evelyn
    McGoldrick, Niall
    Mahapatra, Anant
    Awan, Nasir
    [J]. IRISH JOURNAL OF MEDICAL SCIENCE, 2019, 188 (01) : 149 - 153
  • [28] Cobalt and chromium concentrations in patients with metal-on-metal and other cementless total hip arthroplasty
    Maezawa, K
    Nozawa, M
    Hirose, T
    Matsuda, K
    Yasuma, M
    Shitoto, K
    Kurosawa, H
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2002, 122 (05) : 283 - 287
  • [29] Cobalt and chromium concentrations in patients with metal-on-metal and other cementless total hip arthroplasty
    Katsuhiko Maezawa
    Masahiko Nozawa
    Tomohiko Hirose
    Keiji Matsuda
    Motoo Yasuma
    Katsuo Shitoto
    Hisashi Kurosawa
    [J]. Archives of Orthopaedic and Trauma Surgery, 2002, 122 : 283 - 287
  • [30] Metal ion levels in a triathlete with a metal-on-metal resurfacing arthroplasty of the hip
    De Haan, R.
    Campbell, P.
    Reid, S.
    Skipor, A. K.
    De Smet, K.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2007, 89B (04): : 538 - 541