Differences in Pressure Recovery Between Balloon Expandable and Self-expandable Transcatheter Aortic Valves

被引:0
|
作者
Hoda Hatoum
Rebecca T. Hahn
Scott Lilly
Lakshmi Prasad Dasi
机构
[1] The Ohio State University,Department of Biomedical Engineering
[2] Columbia University Medical Center,Division of Cardiology
[3] The Ohio State University,Division of Cardiovascular Medicine
来源
关键词
Transcatheter aortic valve; Pressure recovery; Doppler; Catheterization; Turbulence; Pressure gradient;
D O I
暂无
中图分类号
学科分类号
摘要
Pressure recovery downstream of the aortic valve constitutes an important factor affecting the calculation of pressure gradient (PG) across the valve and therefore the accuracy of the calculated aortic valve area. Some clinical studies hypothesized that stent and valve cusps design contribute to flow acceleration and Doppler-measured valve gradients across the balloon-expandable transcatheter aortic valve. This study aims at elucidating the physical mechanisms behind pressure recovery variations between Edwards SAPIEN 3 and Medtronic Evolut TAVs through the measurements of sensitive and precise axial pressure profiles. A 23 mm Edwards SAPIEN3 and a 26 mm Medtronic Evolut were deployed in a pulse duplicator. A Millar catheter was used to record 50 cycles of pressure data along the centerline of the valve chamber upstream and downstream of the valve. The peak PG obtained with SAPIEN at vena contracta (VC) is 18.83 ± 0.75 mmHg and after recovery, 9.56 ± 0.78 mmHg. For Evolut at VC, peak PG is 18.25 ± 0.63 mmHg and after recovery, 10.3 ± 0.57 mmHg. The differences in peak PG at VC and at the recovery were statistically significant (p < 0.001). With SAPIEN 3 at VC, the mean PG obtained is 10.11 ± 0.63 mmHg and after recovery 7.06 ± 0.46 mmHg. For Evolut, mean PG at VC is 10.45 ± 0.67 mmHg and after recovery 7.99 ± 0.61 mmHg. The differences between the mean PG between the two valves was not statistically significant at VC (p = 0.71) but significant post-recovery (p < 0.00001). While gradients at the VC are higher with the SAPIEN 3, the net gradient after pressure recovery is significantly lower compared to Evolut TAV. Efficiency of pressure recovery significantly depends on valve type due to stent interference with the recovering blood flow.
引用
收藏
页码:860 / 867
页数:7
相关论文
共 50 条
  • [31] CoreValve® transcatheter self-expandable aortic bioprosthesis
    Bruschi, Giuseppe
    De Marco, Federico
    Martinelli, Luigi
    Klugmann, Silvio
    EXPERT REVIEW OF MEDICAL DEVICES, 2013, 10 (01) : 15 - 26
  • [32] The CENTER-Collaboration: Outcomes in patients undergoing transfemoral transcatheter aortic valve implantation with balloon-expandable valves versus self-expandable valves.
    Vlastra, Wieneke
    Chandrasekhar, Jaya
    Munoz-Garcia, Antonio
    Tchetche, Didier
    Brito, Fabio, Jr.
    Barbanti, Marco
    Kornowski, Ran
    Latib, Azeem
    D'Onofrio, Augusto
    Ribichini, Flavio
    Baan, Jan
    Tijssen, Jan
    Trillo, Ramiro
    Dumonteil, Nicolas
    Abizaid, Alexandre
    Sartori, Samantha
    D'Errigo, Paola
    Fraccaro, Chiara
    Lunardi, Mattia
    Orvin, Katia
    Pagnesi, Matteo
    Del Valle, Raquel
    Modine, Thomas
    Mehran, Roxana
    Piek, Jan
    Delewi, Ronak
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (13) : B3 - B3
  • [33] Differences on Peri-Procedural Blood Flow Dynamics Between Balloon- and Self-Expandable Valves in Patients With Aortic Stenosis Undergoing Transcatheter Aortic Replacement
    Takahashi, Yuki
    Kamiya, Kiwamu
    Nagai, Toshiyuki
    Tsuneta, Satonori
    Hamaya, Takeshi
    Kazui, Sho
    Yasui, Yutaro
    Saiin, Kohei
    Naito, Seiichiro
    Mizuguchi, Yoshifumi
    Takenaka, Sakae
    Tada, Atsushi
    Ishizaka, Suguru
    Kobayashi, Yuta
    Omote, Kazunori
    Sato, Takuma
    Shingu, Yasushige
    Wakasa, Satoru
    Anzai, Toshihisa
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 82 (17) : B139 - B140
  • [34] Long-term outcomes and prosthesis performance after transcatheter aortic valve replacement: results of self-expandable and balloon-expandable transcatheter heart valves
    Tarantini, Giuseppe
    Purita, Paola A. M.
    D'Onofrio, Augusto
    Fraccaro, Chiara
    Frigo, Anna Chiara
    D'Amico, Gianpiero
    Fovino, Luca Nai
    Martin, Marta
    Cardaioli, Francesco
    Badawy, Mostafa R. A.
    Napodano, Massimo
    Gerosa, Gino
    Iliceto, Sabino
    ANNALS OF CARDIOTHORACIC SURGERY, 2017, 6 (05) : 473 - 483
  • [35] CLINICAL OUTCOMES OF THE BALLOON-EXPANDABLE VS SELF-EXPANDABLE VALVES IN PATIENTS UNDERGOING TRANSCATHETER AORTIC VALVE REPLACEMENT - A META-ANALYSIS
    Gan, Eugene
    Keh, Yann Shan
    Fei, Gao
    Ewe, See Hooi
    Amanullah, Mohammed Rizwan
    Chao, Victor
    Lim, Soo Teik
    Ho, Kay Woon
    Yap, Jonathan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2022, 79 (09) : 685 - 685
  • [36] Myocardial Injury Post Transcatheter Aortic Valve Implantation Comparing Mechanically Expanded Versus Self-Expandable Versus Balloon-Expandable Valves
    Rahhab, Zouhair
    Labarre, Quentin
    Nijenhuis, Vincent J.
    El Faquir, Nahid
    de Biase, Chiara
    Philippart, Raphael
    Heijmen, Robin
    Kardys, Isabella
    Dumonteil, Nicolas
    de Jaegere, Peter
    van der Heijden, Jan
    Tchetche, Didier
    Van Mieghem, Nicolas M.
    STRUCTURAL HEART-THE JOURNAL OF THE HEART TEAM, 2019, 3 (05): : 431 - 437
  • [37] AORTIC ANGULATION ATTENUATES PROCEDURAL SUCCESS FOLLOWING SELF-EXPANDABLE BUT NOT BALLOON-EXPANDABLE TRANSCATHETER AORTIC VALVE IMPLANTATION
    Abramowitz, Yigal
    Maeno, Yoshio
    Chakravarty, Tarun
    Mangat, Geeteshwar
    Kazuno, Yoshio
    Takahashi, Nobuyuki
    Kawamori, Hiroyuki
    Nakamura, Mamoo
    Cheng, Wen
    Jilaihawi, Hasan
    Makkar, Raj
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (13) : 1666 - 1666
  • [38] Short-term safety and efficacy of transcarotid transcatheter aortic valve implantation with balloon-expandable vs. self-expandable valves
    Hudziak, Damian
    Wanha, Wojciech
    Gocot, Radoslaw
    Parma, Radoslaw
    Ochala, Andrzej
    Smolka, Grzegorz
    Ciosek, Joanna
    Darocha, Tomasz
    Deja, Marek A.
    Wojakowski, Wojciech
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2021, 17 (01): : 75 - 81
  • [39] Conduction disturbances in low-surgical-risk patients undergoing transcatheter aortic valve replacement with self-expandable or balloon-expandable valves
    Zouari, Fourat
    Campelo-Parada, Francisco
    Matta, Anthony
    Boudou, Nicolas
    Bouisset, Frederic
    Grunenwald, Etienne
    Marcheix, Bertrand
    Carrie, Didier
    Lhermusier, Thibault
    CARDIOVASCULAR INTERVENTION AND THERAPEUTICS, 2021, 36 (03) : 355 - 362
  • [40] The Incidence of Transcatheter Aortic Valve Implantation-Related Heart Block in Self-Expandable Medtronic CoreValve and Balloon-Expandable Edwards Valves
    Liang, Michael
    Devlin, Gerard
    Pasupati, Sanjeevan
    JOURNAL OF INVASIVE CARDIOLOGY, 2012, 24 (04): : 173 - 176